• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Subcircuits
Subcircuits

Vertical deflection circuit for TV and monitor
Vertical deflection circuit for TV and monitor

... This circuit senses the presence of the clock pulse coming from the oscillator stage and the flyback pulse on the yoke. If both of them are present a blanking pulse is generated able to blank the CRT during the retrace period. The duration of this pulse is the same of the one coming from the oscilla ...
industrial accelerometers
industrial accelerometers

... tolerance, the calibrated output of the sensor could range from 90 mV/g (-10%) to 110 mV/g (+10%). However, if you were to choose a 500 mV/g accelerometer with a +/- 10% sensitivity tolerance, the calibrated output of the sensor could range from 450 mV/g (-10%) to 550 mV/g (+10%). Since vibration an ...
One of the most common applications questions on opera-
One of the most common applications questions on opera-

... supply voltages are not available. Furthermore, certain apderive important benefits from single supply operation. 言,采用单电源供电将使其切实的获益。 plications using high voltage and high current op amps can Consider the basic op amp connection shown in Figure la. It derive important benefits from single supply ope ...
IJESRT
IJESRT

... saturation. The parameters have been obtained from practical or experimental measurements. From the study it is seen that sags can produce transformer saturation when voltage recovers. This leads to produce an inrush current that is similar to inrush current produced during the transformer energizin ...
Application Guide Industrial Electronics
Application Guide Industrial Electronics

File
File

S-57P1 S Series HALL IC
S-57P1 S Series HALL IC

... • Note that the IC may malfunction if the power supply voltage rapidly changes. When the IC is used under the environment where the power supply voltage rapidly changes, it is recommended to judge the output voltage of the IC by reading it multiple times. • Do not apply an electrostatic discharge to ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-ISSN: 2278-1676,p-ISSN: 2320-3331,

... operation of the half-bridge VSI in one switching cycle is described in four states. In the first state, the upper switch S1 is turned on; the input current circulates through the primary winding of the HFT to the lower input capacitor CI2. Upper diodes at the secondary side start conducting, and th ...
TPPM0301 数据资料 dataSheet 下载
TPPM0301 数据资料 dataSheet 下载

... Lead temperature (soldering, 10 second), T(LEAD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operati ...
MAX9890 Audio Click-Pop Suppressor General Description Features
MAX9890 Audio Click-Pop Suppressor General Description Features

... single-supply devices such as CODECs and other headphone amplifiers that do not have click-and-pop suppression. Single-supply audio amplifier outputs have a DC bias voltage, VCC / 2, and require large output-coupling capacitors to block the DC voltage from the speaker. During startup or shutdown, th ...
Fault Current Coefficient and Time Delay Assignment for Microgrid Protection System
Fault Current Coefficient and Time Delay Assignment for Microgrid Protection System

... [9], [10]. Since the very basics of conventional network operation do not hold any more (such as grid’s being radial and passive) revolutionary changes are required for safe operation. Protection systems, in particular, are affected heavily by the current contribution of DGs. There are different sol ...
analog multiplexer/demultiplexer
analog multiplexer/demultiplexer

... transition time, if the transition time is less than 12 ms. When the inhibit signal turns a channel off, there is no change dumping of VSS. Rather, there is a slight rise in the channel voltage level (65 mV typ.) due to the capacitance coupling from inhibit input to channel input or output. Address ...
Question 1 (a) Gas ionization processes a. Ionization by simple
Question 1 (a) Gas ionization processes a. Ionization by simple

Reverse-Logic Control of Load Tap Changers in Emergency Voltage
Reverse-Logic Control of Load Tap Changers in Emergency Voltage

P85350 002A
P85350 002A

... WARNING: When installing strobes in an open office or other areas containing partitions or other viewing obstructions, special attention should be given to the location of the strobes so that their operating effect can be seen by all intended viewers, with the intesity, number, and illumination, reg ...
Latest Technology PT IGBTs vs. Power MOSFETs
Latest Technology PT IGBTs vs. Power MOSFETs

... Lower losses as well as lower thermal resistance RθJC result in higher maximum frequency. In general, a device that is thermally capable of the highest switching frequency is the most efficient device. Figure 4 shows usable frequency versus current curves for three devices: a PT IGBT and two power M ...
LM392 LOW-POWER OPERATIONAL AMPLIFIER AND VOLTAGE COMPARATOR FEATURES
LM392 LOW-POWER OPERATIONAL AMPLIFIER AND VOLTAGE COMPARATOR FEATURES

... The input common-mode voltage or either input signal voltage should not be allowed to go negative by more than 0.3 V. The upper end of the common-mode voltage range is V+ – 1.5 V, but either or both inputs can go to 32 V without damage. Due to proximity of external components, ensure that coupling i ...
MOSFETS SOT-323 Plastic-Encapsulate  2SK3018
MOSFETS SOT-323 Plastic-Encapsulate 2SK3018

... JIANGSU CHANGJIANG ELECTRONICS TECHNOLOGY CO., LTD ...
Generator Compatibility of Passive Filters - Trans-Coil
Generator Compatibility of Passive Filters - Trans-Coil

TDA8920B 2 x 100 W class-D power amplifier
TDA8920B 2 x 100 W class-D power amplifier

... of the amplifier is short-circuited to one of the supply lines, this will be detected by the OverCurrent Protection (OCP). If the output current exceeds the maximum output current of 8 A, this current will be limited by the amplifier to 8 A while the amplifier outputs remain switching (the amplifier ...
A 256×256 CMOS active pixel sensor camera-on-a
A 256×256 CMOS active pixel sensor camera-on-a

... Dark current was measured by varying the master clock rate and thus linearly controlling the integration period in the dark. An output-referred, room temperature, dark-current-inducedsignal of 29 mV1s was measured. Based on the conversion gain, this yields a dark current of less than 500 pA/cm2. Con ...
Power MOSFET Basics
Power MOSFET Basics

... temperature the device reaches during this event. Since large chips have a greater heat capacity, they have higher UIS capability in this mode of operation. ...
Lecture 4: Meters and Power
Lecture 4: Meters and Power

... ammeter is in series with Req = (RA + R1 + R3.3 ) The the 1- and 3.3-k resistors.  If RA  0 For the ammeter to have a minimal effect on the equivalent resistance, its resistance  Req  (R1 + R3.3 ) should be small.  Ammeters should have small resistances ...
Equation 7
Equation 7

... 0.6 V to 5.5 V. The conversion input voltage range is from 3 V up to 28V. The D-CAP™ mode uses the ESR of the output capacitor(s) to sense the device current . One advantage of this control scheme is that it does not require an external phase compensation network. This allows a simple design with a ...
< 1 ... 514 515 516 517 518 519 520 521 522 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report