• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
lect01 course overview transducer characteristics
lect01 course overview transducer characteristics

... noise: Noise (in the transducer) consists of signals generated within the transducer, independent of the input signal, which contribute to the output. Such signals may be intrinsic to the transducer (for example, due to thermal fluctuations of carrier concentrations in a semiconductor), or be genera ...
SYNCHRONOUS GENERATOR NO-LOAD VOLTAGE PREDICTION
SYNCHRONOUS GENERATOR NO-LOAD VOLTAGE PREDICTION

... harmonics content of the no-load voltage is essential for satisfying standards requirements (Telephone Harmonic Factor, etc.). Another important point during the design is the prediction of the losses due to currents in the damper bars, induced by the slot pulsation field. There exist presently diff ...
MAX1574 180mA, 1x/2x, White LED Charge Pump in 3mm x 3mm TDFN
MAX1574 180mA, 1x/2x, White LED Charge Pump in 3mm x 3mm TDFN

... Driving Camera Strobes/Flashes The MAX1574’s 180mA output capability makes it suitable for driving white LED camera strobes/flashes. For example, the typical operating circuit drives a 3-LED flash module with up to 60mA/LED. To ensure 180mA total drive capability at low input voltages, increase C1 t ...
section 16920-1 - OPS Schneider Electric
section 16920-1 - OPS Schneider Electric

... The Power Meter should display the time that the device has been in service, displaying hours and minutes. C. Demand All power demand calculations shall use any one of the following calculation methods, selectable by the user: 1) Block Interval Demand. The three following demand calculation modes sh ...
LM1971 Digitally Controlled 62 dB Audio Attenuator with
LM1971 Digitally Controlled 62 dB Audio Attenuator with

... op amp to create a gain controlled amplifier as shown in Figure 8. In this configuration the attenuation levels from Table 1 become gain levels with the largest possible gain value being 62 dB. For most applications, 62 dB of gain will cause signal clipping to occur. However, this can be controlled ...
A NOVELL METHOD OF ELECTRONIC TECHNIQUES FOR SOLVING HIGH
A NOVELL METHOD OF ELECTRONIC TECHNIQUES FOR SOLVING HIGH

... curve is the input signal at OPA. The parameters are like a rectangle signal. It´s a rise up from 0V to 5V in a time of 0.1µs after a delay-time of 5us. The pulse-wide is only 50µs till drop-out to 0V. The expected curve from output-current is nearly input, because the value of shunt is 1 ohm. The y ...
MAX5187/MAX5190 8-Bit, 40MHz, Current/Voltage-Output DACs General Description Features
MAX5187/MAX5190 8-Bit, 40MHz, Current/Voltage-Output DACs General Description Features

... The MAX5187/MAX5190 are designed to provide a high level of signal integrity for the least amount of power dissipation. They operate from a single supply of +2.7V to +3.3V. Additionally, these DACs have three modes of operation: normal, low-power standby, and full shutdown, which provides the lowest ...
$doc.title

... an external parallel–resonant crystal. For a 46/49 MHz cordless phone application, a 10.24 MHz crystal is needed. OSC in may also serve as input for an externally generated reference signal. This signal is typically ac coupled to OSC in, but for larger amplitude signals (standard CMOS logic levels) ...
Instruction Manual • Authorized Electricians blueplanet
Instruction Manual • Authorized Electricians blueplanet

... PV arrays consist of PV modules connected in series and parallel. Each series-connected set is called a string. The electrical properties of the PV array are determined by how many PV modules are in a string, and how many of the strings are connected in parallel. DC circuit connection The PV array c ...
3D ICs: An Opportunity for Fully-Integrated, Dense and - Hal-CEA
3D ICs: An Opportunity for Fully-Integrated, Dense and - Hal-CEA

... equivalent output resistor Rc (Fig. 4.a). It is important to notice our optimization maximizes the power efficiency without guarantee on the output voltage. The SCC provides a sufficiently fast transient response to meet the load transient requirement as proven in [6], [13]. If a small voltage regul ...
ZIP load parameters in this case are evaluated as
ZIP load parameters in this case are evaluated as

... In electrical power systems, a load is defined as a device that is connected to the system for consuming power. A load model is defined as a set of mathematical equations which relate both voltage magnitude and frequency with its active and reactive power consumption [7]. Load modeling is always a d ...
See appendix 1 as a pdf file
See appendix 1 as a pdf file

... earth may under certain circumstances give rise to such electrical influences that it is dangerous to touch the piping and other electrically conductive parts in contact with the piping. I – Electrostatically influenced plants In case of electrostatic influence from a high-voltage overhead wire to a ...
- aes journals
- aes journals

... While the space vector controller is described in [6]. The ramp comparison controller is modeled on a computer in [3] and the delta controller discussed in [4]. This paper uses two criteria of current controllers to evaluate them as a function of operating conditions. The inverter transistor average ...
development of a gate drive with overcurrent
development of a gate drive with overcurrent

... The demand for reliable and high robustness gate driver for power switches is increasing worldwide [1]. It is concomitant with the development of power electronics domain which plays important role for technological enhancement [2]. Most of the conventional gate drive circuit utilize a direct connec ...
Specification Status: Released  PolyZen GENERAL DESCRIPTION
Specification Status: Released PolyZen GENERAL DESCRIPTION

... BENEFITS ...
AR4102321325
AR4102321325

MAX5058/MAX5059 Parallelable Secondary
MAX5058/MAX5059 Parallelable Secondary

Switch power
Switch power

abstract - researchprojects.info
abstract - researchprojects.info

Sat Buddy 2 - Applied Instruments
Sat Buddy 2 - Applied Instruments

PDF
PDF

... Greengate Digital Switch (GDS) ...
Testing Fieldbus Wiring with an FBT-6 and FBT-5
Testing Fieldbus Wiring with an FBT-6 and FBT-5

... The FBT-5 was designed for testing a single cable only. Testing a cabling system with the FBT-5 has limitations. 2.1.1. Do not attach fieldbus devices The cable system must not have fieldbus devices attached to it during the test. The FBT-5 can not power fieldbus devices and its signal generator wil ...
Capacitor Aplication..
Capacitor Aplication..

... (VAr). The purpose is to counteract inductive loading from devices like electric motors and transmission lines to make the load appear to be mostly resistive. Individual motor or lamp loads may have capacitors for power factor correction, or larger sets of capacitors (usually with automatic switchin ...
Implementation Of Low Power 3-Bit Flash ADC Using
Implementation Of Low Power 3-Bit Flash ADC Using

... channel instead of one gate [5]. The gates surrounding the conducting channel ensure that a better control over channel can be applied, which reduces the leakage currents, the drain induced barrier lowering and other short channel effects and power dissipation. Depletion charges in Double gate MOSFE ...
New Real time Voltage Stability Indicators Based on Phasor
New Real time Voltage Stability Indicators Based on Phasor

... power at the receiving end of the transmission line to infer the voltage instability proximity, whereas the work [6] uses the same concept of Thevenin equivalent and relies on the Tellegen’s theorem to identify the Thevenin parameters. In the paper [4], the authors extend the previous analyses to Z ...
< 1 ... 484 485 486 487 488 489 490 491 492 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report