• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD
ACD-50NAV, ACD-51NAV, ACDC-52NAV, ACD

... Measurement Category III (CAT III) is for measurements performed in the building installation. Examples are measurements on distribution boards, circuit- breakers, wiring, including cables, bus-bars, junction boxes, switches, socket-outlets in the fixed installation, and equipment for industrial use ...
ADP3334 High Accuracy, Low IQ, anyCAP® Adjustable Low
ADP3334 High Accuracy, Low IQ, anyCAP® Adjustable Low

... A capacitor as low as 1 µF is all that is needed for stability; larger capacitors can be used if high output current surges are anticipated. The ADP3334 is stable with extremely low ESR capacitors (ESR ⬇ 0), such as multilayer ceramic capacitors (MLCC) or OSCON. Note that the effective capacitance o ...
cause the controllers operating the turbine converters are not
cause the controllers operating the turbine converters are not

rectifier report - Kaushik Science Projects
rectifier report - Kaushik Science Projects

DC and AC Motor Drives
DC and AC Motor Drives

... Induction Motor Drives: Rotor Voltage Control • In a wound-rotor motor, an external three-phase resistor may be connected to its slip rings, as shown in Figure 16.5a. • The developed torque may be varied by varying the resistance Rx. If Rx is referred to the stator winding and added to Rr, Eq. (16. ...
AC Capacitors 1000-7000 VAC, Film Capacitors with Aluminum Foil
AC Capacitors 1000-7000 VAC, Film Capacitors with Aluminum Foil

... inverter. On many designs, we may then have snubber capacitors. On the output, we may have parallel or series resonant capacitors. For film technology, typical frequencies for resonant capacitors may be up to 500 kHz. ...
ESF.ESFP Smart battery charger user manual
ESF.ESFP Smart battery charger user manual

Electric generator
Electric generator

... sion is perpendicular to the rotor axis, the foils being held it being therefore necessary to provide compensating speed regulating devices if it is desired to maintain a substan 30 together by rivets or other suitable fastening means. If the ferromagnetic elements are part of the rotor, the tially ...
Power-supply rail rejection
Power-supply rail rejection

... PSRR is usually best dealt with by RC filtering in a discrete-component power amplifier. This will, however, be ineffective against the sub-50 Hz VLF signals that result from short-term mains voltage variations being reflected in the HT rails. A design relying wholly on RC filtering might have low A ...
AT044289292
AT044289292

... High speed and low power comparators are the essential building blocks of high speed Analog to digital converters (ADCs). This paper provides a comprehensive review about a variety of comparator designs - in terms of performance, power and delay. Preamplifier dynamic latch circuit that consists of a ...
parameters which affect real and reactive power flow
parameters which affect real and reactive power flow

Common-Emitter Amplifier - ee.iitb
Common-Emitter Amplifier - ee.iitb

Multiple Clock and Voltage Domains for Chip Multi Processors
Multiple Clock and Voltage Domains for Chip Multi Processors

... showed distinct phases during which the CPU remained stable before transitioning to a different phase. Choi et el. [5] implemented a power management algorithm on Intel® Xscale® by observing memory-bound phases of a workload. A hardware mechanism tracked CPU behavior; when a CPU accesses external me ...
LVDT
LVDT

... the coil's axis, but is generally insensitive to cross-axis motion of the core or to its radial position. Thus, an LVDT can usually function without adverse effect in applications involving misaligned or floating moving members, and in cases where the core doesn't always travel in a ...
W. Inam, K.K. Afridi, and D.J. Perreault, “High Efficiency Resonant dc/dc Converter Utilizing a Resistance Compression Network,” IEEE Transactions on Power Electronics , Vol. 29, No. 8, pp. 4126-4136, August 2014.
W. Inam, K.K. Afridi, and D.J. Perreault, “High Efficiency Resonant dc/dc Converter Utilizing a Resistance Compression Network,” IEEE Transactions on Power Electronics , Vol. 29, No. 8, pp. 4126-4136, August 2014.

... power when output load or input voltage varies such that the magnetics cannot be optimally designed. Furthermore, to maintain zero-voltage switching the frequency must increase to reduce power, hurting the efficiency at light load. For a fullbridge version of the SRC, phase shift control can be used ...
BU52272NUZ - ROHM Semiconductor
BU52272NUZ - ROHM Semiconductor

... when distance increases magnetic density falls. When it drops below the operate point (Bop), output goes HIGH. When the magnet gets closer to the IC and magnetic density rises to the operate point, the output switches LOW. In LOW output mode, the distance from the magnet to the IC increases again un ...
Medium Voltage Switchgear
Medium Voltage Switchgear

DC2132A - Linear Technology
DC2132A - Linear Technology

... (potentiometer). That voltage directly sets the output voltage of the LT3081. The maximum output voltage can be set to three settings: 24V, 15V and 5.5V with the shunt position on JP1. The setting should be changed according to the choice of input voltage. A 36V, 24V, or 12V AC/DC converter can be u ...
Design considerations for charge-compensated
Design considerations for charge-compensated

... redesign with respect to the targeted nominal blocking voltage (approach 2) show a clearly reduced on-resistance for the product. Fig. 15 shows important figure-of-merits in order to evaluate the dynamic device properties. This comparison is important as the devices are widely used in applications w ...
the overview brochure - Kniel System
the overview brochure - Kniel System

... Individual production and maximum efficiency are not contradictory at Kniel. This is particularly the case in view of broad product diversity and small quantities. In addition to our state-ofthe-art, automated production workflow, we bank on streamlined manual operations: always in new configuration ...
Topic 12_2__Alternating current
Topic 12_2__Alternating current

... This relationship shows that I and V are proportional to each other and in phase. This may seem an obvious relationship but in AC Consumes circuits there are comenergy ponents called capacitors and inductors which change Stores the phase relationship B-field between I and V. Stores FYI IB does NO ...
Low Power DC/DC Boost Converter in SOT-23
Low Power DC/DC Boost Converter in SOT-23

... The TPS6104x operates with an input voltage range of 1.8 V to 6 V and can generate output voltages up to 28 V. The device operates in a pulse-frequency-modulation (PFM) scheme with constant peak current control. This control scheme maintains high efficiency over the entire load current range, and wi ...
Power Supply Wattage
Power Supply Wattage

... much smaller and lighter. They convert the 60Hertz (Hz, or cycles per second) current to a much higher frequency, meaning more cycles per second. ...
Manual - Major Tech
Manual - Major Tech

... WARNING: Risk of electrocution. High-voltage circuits, both AC and DC, are very dangerous and should be measured with great care. 1. ALWAYS turn the function switch to the OFF position when the meter is not in use. 2. If “OL” appears in the display during a measurement, the value exceeds the range y ...
Digital I/O Board Kit (#27113)
Digital I/O Board Kit (#27113)

... combination. The slots are mechanically interlocked to prevent you from using both types in the same position. The Mechanical Relays can switch up to 250VAC @ 12A (24VDC). The Solid State Relays can switch up to 240VAC @ 8A (AC ONLY). Unlike the mechanical relays, solid state relays do not exhibit c ...
< 1 ... 445 446 447 448 449 450 451 452 453 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report