FEATURES DESCRIPTION D
... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
... This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with appropriate precautions. Failure to observe proper handling and installation procedures can cause damage. ESD damage can range from subtle performance degradation to complete devi ...
Sunny Tripower 12000/15000/20000/24000 TL-US
... • The AC output/neutral is not bonded to ground inside of the inverter. The product is suitable for indoor and outdoor use. The Sunny Tripower must only be operated with PV arrays (PV modules and cabling) that are approved by the electrical standards applicable on-site and the National Electrical Co ...
... • The AC output/neutral is not bonded to ground inside of the inverter. The product is suitable for indoor and outdoor use. The Sunny Tripower must only be operated with PV arrays (PV modules and cabling) that are approved by the electrical standards applicable on-site and the National Electrical Co ...
Din-Rail (SPD) Surge Protective Device and Filter for Instantaneous Protection
... and Filter for Instantaneous Protection of Sensitive Electronics DIN1 PLUS Surge Protective Devices deliver worry-free performance with an innovative and proven technology design. All models provide surge protection against harmful transient voltage and high-frequency noise that exceed the nominal o ...
... and Filter for Instantaneous Protection of Sensitive Electronics DIN1 PLUS Surge Protective Devices deliver worry-free performance with an innovative and proven technology design. All models provide surge protection against harmful transient voltage and high-frequency noise that exceed the nominal o ...
DATA SHEET BLY88C VHF power transistor August 1986
... more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods ...
... more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods ...
application to airflow control by plasma actuators.
... remark that the flow separation is still at mid-chord since the angle of attack is higher than in the previous study. This is due to the fact that in the present study, there is no tripper at the leading edge of the airfoil because the actuator is located at the leading edge. Two different actuation ...
... remark that the flow separation is still at mid-chord since the angle of attack is higher than in the previous study. This is due to the fact that in the present study, there is no tripper at the leading edge of the airfoil because the actuator is located at the leading edge. Two different actuation ...
C-Bus 8 Channel Dimmer, DIN Rail Series
... tracked and all harmonics and non-harmonics of the fundamental frequency are filtered. This special algorithm ensures that lights do not flicker due to signal injections on the mains from the power authorities. • Programmable thresholds or limits on each dimmer channel, variable from 0 - 100%. For e ...
... tracked and all harmonics and non-harmonics of the fundamental frequency are filtered. This special algorithm ensures that lights do not flicker due to signal injections on the mains from the power authorities. • Programmable thresholds or limits on each dimmer channel, variable from 0 - 100%. For e ...
ADS7816 数据资料 dataSheet 下载
... this, the differential input can be used to reject only small signals that are common to both inputs. Thus, the –In input is best used to sense a remote signal ground that may move slightly with respect to the local ground potential. ...
... this, the differential input can be used to reject only small signals that are common to both inputs. Thus, the –In input is best used to sense a remote signal ground that may move slightly with respect to the local ground potential. ...
AN-1718 Differential Amplifier Applications Up
... The LMH6515 is an open collector topology and has the option of two different output configurations. Each output has an on chip 200Ω pull-up resistor. In addition, there is an internal 400Ω resistor between the two outputs. This results in a 200Ω or a 400Ω differential load in parallel with the exte ...
... The LMH6515 is an open collector topology and has the option of two different output configurations. Each output has an on chip 200Ω pull-up resistor. In addition, there is an internal 400Ω resistor between the two outputs. This results in a 200Ω or a 400Ω differential load in parallel with the exte ...
MV Switchgear 5kVMetal-Clad Indoor
... specified by the local utility. The construction shall conform to the utility company’s metering standards as specified by the local utility’s specifications. It shall also conform to the general electrical and construction design of the switchgear specified above. ...
... specified by the local utility. The construction shall conform to the utility company’s metering standards as specified by the local utility’s specifications. It shall also conform to the general electrical and construction design of the switchgear specified above. ...
CBDS - Anasim
... LVDS links, ubiquitous for high-speed data interfaces, operate from high voltage supplies such as 3.3V. CBDS operates from high or low operating voltages such as 1V with upto 500mV signal swing, or 1V differentially. The lower supply voltage greatly reduces operating power, a critical design require ...
... LVDS links, ubiquitous for high-speed data interfaces, operate from high voltage supplies such as 3.3V. CBDS operates from high or low operating voltages such as 1V with upto 500mV signal swing, or 1V differentially. The lower supply voltage greatly reduces operating power, a critical design require ...
datasheet
... Create and store a complete library of configurations that can be uploaded as needed Zoom in and out and pan through sections of the graph to analyze the data Download, display and analyze recorded data Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event l ...
... Create and store a complete library of configurations that can be uploaded as needed Zoom in and out and pan through sections of the graph to analyze the data Download, display and analyze recorded data Display waveforms, trend graphs, harmonic spectrums, text summaries, transients, event l ...
PDF
... voltage can be greater than, less than or equal to the output voltage. Hence for this small scale application such as battery it is needed to regulate the output voltage of the converter with high precision & performance. Thus, a trade-off among cost, efficiency, and output transients should be cons ...
... voltage can be greater than, less than or equal to the output voltage. Hence for this small scale application such as battery it is needed to regulate the output voltage of the converter with high precision & performance. Thus, a trade-off among cost, efficiency, and output transients should be cons ...
ups - WordPress.com
... The fuse-holder BCB is installed only on the units with internal batteries (20 and 30kVA). The battery switch is not installed on units having higher power The forced cooling of the heatsink is provided starting from the 40kVA The rectifiers of the 500kVA and 650kVA uses two three-phase rectif ...
... The fuse-holder BCB is installed only on the units with internal batteries (20 and 30kVA). The battery switch is not installed on units having higher power The forced cooling of the heatsink is provided starting from the 40kVA The rectifiers of the 500kVA and 650kVA uses two three-phase rectif ...
MAX253 Transformer Driver for Isolated RS-485 Interface _______________General Description
... communications are obtained by combining the MAX253 with a linear regulator, a center-tapped transformer, optocouplers, and the appropriate Maxim interface product (as described in the Isolated RS-485/RS232 Data Interface section). The MAX253 consists of an RC oscillator followed by a toggle flip-fl ...
... communications are obtained by combining the MAX253 with a linear regulator, a center-tapped transformer, optocouplers, and the appropriate Maxim interface product (as described in the Isolated RS-485/RS232 Data Interface section). The MAX253 consists of an RC oscillator followed by a toggle flip-fl ...
MAX6979 16-Port, 5.5V Constant-Current LED Driver with LED Fault Detection and Watchdog
... The MAX6979 includes a watchdog circuit that monitors the CLK, DIN, and LE inputs. If there is no transition on all of these inputs for nominally 1s, then the output latches are cleared and outputs OUT0–OUT15 go high impedance like the initial power-up condition. This turns off all LEDs connected to ...
... The MAX6979 includes a watchdog circuit that monitors the CLK, DIN, and LE inputs. If there is no transition on all of these inputs for nominally 1s, then the output latches are cleared and outputs OUT0–OUT15 go high impedance like the initial power-up condition. This turns off all LEDs connected to ...
Power Network-on-Chip for Scalable Power Delivery
... with minimum energy loss is an essential component of integrated circuits. To facilitate the integration of diverse functions, architectural, circuit, device, and material level power delivery solutions are required. The quality of the power supply can be efficiently addressed with point-of-load (PO ...
... with minimum energy loss is an essential component of integrated circuits. To facilitate the integration of diverse functions, architectural, circuit, device, and material level power delivery solutions are required. The quality of the power supply can be efficiently addressed with point-of-load (PO ...
Eaton 9390 UPS Brochure
... are non-linear. When voltage is applied to a circuit constructed of non-linear components, the circuit may not respond linearly (current may not follow the voltage in a linear manner). These components may even create frequencies other than the fundamental applied frequency (60 Hz). These frequencie ...
... are non-linear. When voltage is applied to a circuit constructed of non-linear components, the circuit may not respond linearly (current may not follow the voltage in a linear manner). These components may even create frequencies other than the fundamental applied frequency (60 Hz). These frequencie ...