Evaluates: MAX1848 MAX1848 Evaluation Kit General Description Features
... The MAX1848 EV kit contains a switching-regulator current-source circuit. The EV kit’s circuit is configured to drive three series-connected LEDs. The EV kit can be powered by a 2.6V to 5.5V DC source. The MAX1848 EV kit features programmable LED brightness by controlling LED current, overvoltage pr ...
... The MAX1848 EV kit contains a switching-regulator current-source circuit. The EV kit’s circuit is configured to drive three series-connected LEDs. The EV kit can be powered by a 2.6V to 5.5V DC source. The MAX1848 EV kit features programmable LED brightness by controlling LED current, overvoltage pr ...
BDTIC www.BDTIC.com/infineon TLE4921-5U
... 1) The Current consumption characteristic will be different and the specified values can slightly change ...
... 1) The Current consumption characteristic will be different and the specified values can slightly change ...
A3517 and A3518 - Allegro Microsystems
... For safe, reliable operation, the output should not be pulled above the supply voltage or pulled below the device ground. For optimum performance, a 0.1 µF capacitor between the supply and ground, and a 100 pF capacitor between the output and ground, should be added. The ratiometric feature is espec ...
... For safe, reliable operation, the output should not be pulled above the supply voltage or pulled below the device ground. For optimum performance, a 0.1 µF capacitor between the supply and ground, and a 100 pF capacitor between the output and ground, should be added. The ratiometric feature is espec ...
INSTALLATION MANUAL MIG300 MICRO INVERTER
... Lightning does not actually need to strike the equipment or building where the PV system is installed to cause damage. Often, a strike nearby will induce voltage spikes in the electrical grid that can damage equipment. Darfon’s micro inverters have integral surge protection; however, if the surge ha ...
... Lightning does not actually need to strike the equipment or building where the PV system is installed to cause damage. Often, a strike nearby will induce voltage spikes in the electrical grid that can damage equipment. Darfon’s micro inverters have integral surge protection; however, if the surge ha ...
OPA4188 0.03-μV/°C Drift, Low-Noise, Rail-to
... Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Input terminals are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5-V beyond the supply rails should be current-limited to 10 mA or less. Short- ...
... Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Input terminals are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5-V beyond the supply rails should be current-limited to 10 mA or less. Short- ...
Power supplies and DC/DC converters
... PL series All Lambda PL series are designed on the DOSA-standard. Single Inline models and SMT types are available over the complete power range from 5 A up to 20 A. Low logic voltages with load transients frequently require point of load supply voltage. The PL series provide all logic voltages betw ...
... PL series All Lambda PL series are designed on the DOSA-standard. Single Inline models and SMT types are available over the complete power range from 5 A up to 20 A. Low logic voltages with load transients frequently require point of load supply voltage. The PL series provide all logic voltages betw ...
MAX8836Z 1.2A PWM Step-Down Converter in General Description
... Thermal shutdown limits total power dissipation in the MAX8836Z. If the junction temperature exceeds +160°C, thermal-shutdown circuitry turns off the IC, allowing it to cool. The IC turns on and begins soft-start after the junction temperature cools by 20°C. This results in a pulsed output during co ...
... Thermal shutdown limits total power dissipation in the MAX8836Z. If the junction temperature exceeds +160°C, thermal-shutdown circuitry turns off the IC, allowing it to cool. The IC turns on and begins soft-start after the junction temperature cools by 20°C. This results in a pulsed output during co ...
Document
... 49 •• [SSM] An insulated wire that has a resistance of 18.0 /m and a length of 9.00 m will be used to construct a resistor. First, the wire is bent in half and then the doubled wire is wound on a cylindrical form ( Figure 28-50) to create a 25.0-cm-long helix that has a diameter equal to 2.00 cm. F ...
... 49 •• [SSM] An insulated wire that has a resistance of 18.0 /m and a length of 9.00 m will be used to construct a resistor. First, the wire is bent in half and then the doubled wire is wound on a cylindrical form ( Figure 28-50) to create a 25.0-cm-long helix that has a diameter equal to 2.00 cm. F ...
Ferroresonance in Three-Phase Power Distribution Transformers
... units or those with triplex construction). This way, single phase operations will not induce voltages on the other phases. The only possibility for ferroresonance to appear would be the existence of capacitor banks or important phase to phase capacitive coupling (figure 2). Nowadays, other core desi ...
... units or those with triplex construction). This way, single phase operations will not induce voltages on the other phases. The only possibility for ferroresonance to appear would be the existence of capacitor banks or important phase to phase capacitive coupling (figure 2). Nowadays, other core desi ...
Presentation Title Here
... • Internal ESD circuits may sufficiently handle EOS • Be aware of unique EOS situations such as power up and input slewing • External EOS protection circuits will be required if device damage is likely to occur without it ...
... • Internal ESD circuits may sufficiently handle EOS • Be aware of unique EOS situations such as power up and input slewing • External EOS protection circuits will be required if device damage is likely to occur without it ...
Dual Differential Line Driver With 3-State Outputs
... § In ANSI Standard EIA/TIA-422-B, VOC, which is the average of the two output voltages with respect to GND, is called output offset voltage, VOS. ¶ Only one output should be shorted at a time, and duration of the short circuit should not exceed one second. ...
... § In ANSI Standard EIA/TIA-422-B, VOC, which is the average of the two output voltages with respect to GND, is called output offset voltage, VOS. ¶ Only one output should be shorted at a time, and duration of the short circuit should not exceed one second. ...
MAX14529E/MAX14530E Overvoltage Protection with USB Charger General Description
... Overvoltage Protection with USB Charger Detection, LDO, and ESD Protection on D+/DThe MAX14529E/MAX14530E are overvoltage-protection devices with USB charger detection, a low-dropout (LDO) regulator, and ESD protection. These devices feature a low 35mΩ (typ) RON internal FET switch and protect low-v ...
... Overvoltage Protection with USB Charger Detection, LDO, and ESD Protection on D+/DThe MAX14529E/MAX14530E are overvoltage-protection devices with USB charger detection, a low-dropout (LDO) regulator, and ESD protection. These devices feature a low 35mΩ (typ) RON internal FET switch and protect low-v ...
A+ Guide to Hardware
... • Troubleshooting nonfunctional fan – Turn off power; remove all power cord connections to all components except motherboard; turn on power – Turn off power; reconnect one card or drive at a time – Motherboard power supply problem • Fan does not work when all devices except ...
... • Troubleshooting nonfunctional fan – Turn off power; remove all power cord connections to all components except motherboard; turn on power – Turn off power; reconnect one card or drive at a time – Motherboard power supply problem • Fan does not work when all devices except ...
1. What is the nature from a safety standpoint of the switch in the
... to 8 hard-wired circuits. This limits the number of circuits you can connect to the transfer switch. iii. Since GenerLink uses your existing breaker panel, you can run any large 120 or 240-volt appliance up to your generator’s capacity. Your well pump, water heater, sump pump, electric range, clothe ...
... to 8 hard-wired circuits. This limits the number of circuits you can connect to the transfer switch. iii. Since GenerLink uses your existing breaker panel, you can run any large 120 or 240-volt appliance up to your generator’s capacity. Your well pump, water heater, sump pump, electric range, clothe ...
Analog Dialogue Volume 48 Number 3
... that operate at different ground potentials. To ensure troublefree card insertion/removal and robust operation, each interface must be isolated, but isolating I2C interfaces is complicated because the bus is bidirectional. This requirement is not compatible with optocouplers, which are unidirectiona ...
... that operate at different ground potentials. To ensure troublefree card insertion/removal and robust operation, each interface must be isolated, but isolating I2C interfaces is complicated because the bus is bidirectional. This requirement is not compatible with optocouplers, which are unidirectiona ...
Lecture 15 P-N Junction Diodes: Part 5 Large signal (complete
... •Superposition principle allows us to separate DC and AC analysis of circuits containing active devices (like diodes, transistors, amplifiers etc...). •We assume the AC signals are small enough so that the circuit behaves linearly and can be analyzed by replacing “non-linear” components by “Linear E ...
... •Superposition principle allows us to separate DC and AC analysis of circuits containing active devices (like diodes, transistors, amplifiers etc...). •We assume the AC signals are small enough so that the circuit behaves linearly and can be analyzed by replacing “non-linear” components by “Linear E ...
TMP01 数据手册DataSheet 下载
... The total R1 + R2 + R3 is equal to the load resistance needed to draw the desired hysteresis current from the reference, or IVREF. The formulas shown above are also helpful in understanding the calculation of temperature setpoint voltages in circuits other than the standard two-temperature thermosta ...
... The total R1 + R2 + R3 is equal to the load resistance needed to draw the desired hysteresis current from the reference, or IVREF. The formulas shown above are also helpful in understanding the calculation of temperature setpoint voltages in circuits other than the standard two-temperature thermosta ...
UCC28730 Constant-Voltage, Constant-Current
... VDD is the bias supply input pin to the controller. A carefully-placed by-pass capacitor to GND is required on this pin. ...
... VDD is the bias supply input pin to the controller. A carefully-placed by-pass capacitor to GND is required on this pin. ...
Comparative Analysis of Conventional CMOS and
... of power gating to achieve long term leakage power reduction. To shut off the block for small intervals of time, internal power gating is more suitable. CMOS switches that provide power to the circuitry are controlled by power gating controllers. Outputs of the power gated block discharge slowly. La ...
... of power gating to achieve long term leakage power reduction. To shut off the block for small intervals of time, internal power gating is more suitable. CMOS switches that provide power to the circuitry are controlled by power gating controllers. Outputs of the power gated block discharge slowly. La ...
Managing Power with CoolRunner-II CPLDs Summary
... from, walkie-talkies to PDAs, to video cameras, to the emerging software defined radios (SDR). 3G cell phones, in particular, with their added on applications and multi-band operation take this type of power management to new heights. In fact, these systems may rival some of the very power conscious ...
... from, walkie-talkies to PDAs, to video cameras, to the emerging software defined radios (SDR). 3G cell phones, in particular, with their added on applications and multi-band operation take this type of power management to new heights. In fact, these systems may rival some of the very power conscious ...