• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
X - CDMS
X - CDMS

Optimal placement of shunt connected facts device in a series long
Optimal placement of shunt connected facts device in a series long

... We may like to control the power flow in a AC transmission line to (a) enhance power transfer capacity and or (b) to change power flow under dynamic conditions (subjected to disturbances such as sudden increase in load, line trip or generator outage) to ensure system stability and security. The stab ...
DN302 - Ultraprecise Instrumentation Amplifier Makes Robust Thermocouple Interface
DN302 - Ultraprecise Instrumentation Amplifier Makes Robust Thermocouple Interface

... precludes the need to temperature stabilize the thermocouple “cold junctions” and removes the accuracy penalty of a static room temperature correction value. The output of the LT1025 provides a 10mV/°C correction voltage for the ambient temperature difference from 0°C—normally about 250mV at room te ...
Load, Switch, and Commutation Considerations
Load, Switch, and Commutation Considerations

... Power Electronics ...
ILX511 - Ocean Optics
ILX511 - Ocean Optics

... Dummy Signal (32 pixels) ...
High-Efficiency, Low-Supply-Current, Compact, Step-Up DC-DC Converters General Description ____________________________Features
High-Efficiency, Low-Supply-Current, Compact, Step-Up DC-DC Converters General Description ____________________________Features

... connects an external resistor (R1) across the inductor when the inductor’s energy is depleted (Figure 2). Normally, when the energy in the inductor is insufficient to supply current to the output, the capacitance and inductance at LX form a resonant circuit that causes ringing. The ringing continues ...
Phasor Measurement (Estimation) Units
Phasor Measurement (Estimation) Units

... Synchronized Phasor, Frequency, and Rate of Change of Frequency (ROCOF) estimates from voltage and/or current signals and a time synchronizing signal”. •  Phasor Measurement Unit (PMU) – A transducer that converts three-phase analog signal of voltage or current into Synchrophasors ...
AN51 - Power Conditioning for Notebook and Palmtop Systems
AN51 - Power Conditioning for Notebook and Palmtop Systems

... to swing high with about 200µA sourcing capability. The LT1432 VC pin then sinks this current to control the loop. C4 forms the dominant loop pole with a loop zero added by R1. C5 forms a higher frequency loop pole to control switching ripple at the VC pin. A floating 5V power supply for the switche ...
ADP1829 数据手册DataSheet 下载
ADP1829 数据手册DataSheet 下载

... The ADP1829 is a versatile, dual, interleaved, synchronous PWM buck controller that generates two independent output rails from an input of 3.0 V to 18 V, with power input voltage ranging from 1.0 V to 24 V. Each controller can be configured to provide output voltages from 0.6 V to 85% of the input ...
A. POWER METERS-Advanced
A. POWER METERS-Advanced

... (i) THD – Voltage, Current (3-Phase, Per-Phase, Neutral) (ii) thd - Voltage, Current (3-Phase, Per-Phase, Neutral) (iii) Displacement Power Factor (Per-Phase, 3-Phase) (iv) Fundamental Voltage, Magnitude and Angle (Per-Phase) (v) Fundamental Currents, Magnitude and Angle (Per-Phase) (vi) Fundamental ...
Evaluates:  MAX16834 MAX16834 Evaluation Kit General Description Features
Evaluates: MAX16834 MAX16834 Evaluation Kit General Description Features

... optional step-up/step-down (buck-boost) operation. The MAX16834 EV kit operates from a DC supply voltage of 7V to 28V and requires up to 5A. The MAX16834 EV kit circuit is configured to deliver up to 1A of current into series LEDs with a maximum forward voltage of 28V. The MAX16834 EV kit features t ...
Low Dropout 1 Ampere Linear Regulator Family
Low Dropout 1 Ampere Linear Regulator Family

FEATURES DESCRIPTION D
FEATURES DESCRIPTION D

... Lead Temperature (soldering, 10s) . . . . . . . . . . . . . . . . . . . . +300°C Junction Temperature (TJ) . . . . . . . . . . . . . . . . . . . . . . . . . . . +150°C ESD Rating: Human Body Model (HBM) . . . . . . . . . . . . . . . . . . . . . . . 2000V Charge Device Model (CDM) . . . . . . . . . . ...
Vibration and Monitoring Terms Glossary
Vibration and Monitoring Terms Glossary

... output that require the monitor to also have internal signal conditioning, it is referred to as a “vibration input” monitor. When a monitor accepts only 4-20 mA inputs from vibration transmitters (such as a PLC, DCS or certain Metrix products) it is often referred to as a “4-20 mA input” monitor. ...
Manual - Inverter system PCI10
Manual - Inverter system PCI10

... The manual bypass switch bypasses the electronic bypass unit to make it possible to disconnect the latter for maintenance. With this built-in switch the bypass is performed by means of a contactor, which first disconnects the output of the bypass switch and then connects the alternative mains input ...
Frequency and power dependence of spin
Frequency and power dependence of spin

... insulating material yttrium iron garnet (YIG, 1.3 μm), coupled with a thin layer of platinum (Pt, 10 nm). It has been shown experimentally that the combination of these materials and the mentioned phenomena can be used to transmit electrical information over several millimeters.6,8,9 The insulator/n ...
Aalborg Universitet Shafiee, Qobad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez
Aalborg Universitet Shafiee, Qobad; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

... control of the load bus voltage, combined with a reference that is drooped against reactive power output. Further, active power sharing has improved by computing and setting the phase angle of the DGs instead of its frequency in conventional frequency droop control. In [22], a control strategy which ...
A. POWER METERS
A. POWER METERS

3 rd Harmonic Currents - Maryland Public Service Commission
3 rd Harmonic Currents - Maryland Public Service Commission

... Summary of Benefits ...
MAX1759 Buck/Boost Regulating Charge Pump in µMAX General Description
MAX1759 Buck/Boost Regulating Charge Pump in µMAX General Description

... allows the input voltage to be higher or lower than the regulated output voltage. Internal circuitry senses VIN and V OUT and determines whether V IN must be stepped up or stepped down to produce the regulated output. When VIN is lower than VOUT, the charge pump operates as a regulated step-up volta ...
Grid Code - Planning Code
Grid Code - Planning Code

... The transmission network development plan (TNDP) is a document that describes the actual and predicted future changes, reinforcements, additions and removals to the transmission network. This document also shows the opportunities for future connections and indicates those parts of the transmission n ...
Slides - Indico
Slides - Indico

... plasma discharge is generated in the cavity. • This is almost always associated with some of the cavity walls being heated until it vaporises and the gas is then ionised by field emission. The exact mechanisms are still not well understood. • When this occurs all the incoming RF is reflected back up ...
BD00C0AWFPS-M
BD00C0AWFPS-M

... Exceeding the absolute maximum rating for supply voltage, operating temperature or other parameters can result in damages to or destruction of the chip. In this event it also becomes impossible to determine the cause of the damage (e.g. short circuit, open circuit, etc). Therefore, if any special mo ...
A/V Power Mgmt - Which Devices To Buy
A/V Power Mgmt - Which Devices To Buy

A. POWER METERS-Advanced
A. POWER METERS-Advanced

... (i) THD – Voltage, Current (3-Phase, Per-Phase, Neutral) (ii) thd - Voltage, Current (3-Phase, Per-Phase, Neutral) (iii) Displacement Power Factor (Per-Phase, 3-Phase) (iv) Fundamental Voltage, Magnitude and Angle (Per-Phase) (v) Fundamental Currents, Magnitude and Angle (Per-Phase) (vi) Fundamental ...
< 1 ... 352 353 354 355 356 357 358 359 360 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.