• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
How to use the Agilent N6700 Series Agilent 662xA
How to use the Agilent N6700 Series Agilent 662xA

... must have equivalent current ratings. If the current ratings are not equivalent, the higher rated output could potentially damage the lower rated output by forcing excessive current through it under certain load conditions. Floating voltages must not exceed 240 Vdc. Therefore, no output terminal may ...
Single Cell Lithium-Ion Charge Management Controller
Single Cell Lithium-Ion Charge Management Controller

... junction temperature rise is 90°C, approximately. This would allow for a maximum operating ambient temperature of 60°C. By increasing the size of the copper pad, a higher ambient temperature can be realized or a lower value sense resistor could be utilized. Alternatively, different package options c ...
Analysis of Transient Power-angle Characteristic for Synchronous
Analysis of Transient Power-angle Characteristic for Synchronous

Critical Conduction Mode (CRM) Buck Converter with Tapped
Critical Conduction Mode (CRM) Buck Converter with Tapped

AND8394 - Power Factor Corrected Power Supply for LED Drivers
AND8394 - Power Factor Corrected Power Supply for LED Drivers

... circuit for the NCP1652A which uses a peak detector to sample the input haversine. This circuit, along with optional TVS Z1, also doubles as a transient suppression circuit in the event of short duration, high amplitude line transients that input capacitor C3 would be unable to suppress. Input EMI f ...
chapter 4 pitch control of wind turbine generators
chapter 4 pitch control of wind turbine generators

... world basis. India has one of the fifth largest wind power installed capacity in the world. This chapter describes the modeling of the various components in a pitch controlled wind energy system. It also describes the design of the pitch controller and discusses the response of the pitch-controlled ...
LM723QML Voltage Regulator (Rev. A)
LM723QML Voltage Regulator (Rev. A)

MAX9030/MAX9031/ MAX9032/MAX9034 Low-Cost, Ultra-Small, Single/Dual/Quad Single-Supply Comparators
MAX9030/MAX9031/ MAX9032/MAX9034 Low-Cost, Ultra-Small, Single/Dual/Quad Single-Supply Comparators

... applications from +2.5V to +5.5V but can also be operated from dual supplies. These comparators have a 188ns propagation delay and consume 35µA of supply current per comparator over the -40°C to +125°C operating temperature range. The combination of lowpower, single-supply operation down to +2.5V, a ...
R6012ANJ
R6012ANJ

... Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fi ...
Application Report www.BDTIC.com/TI Understanding Boost Power
Application Report www.BDTIC.com/TI Understanding Boost Power

... The three basic switching power supply topologies in common use are the buck, boost, and buck-boost. These topologies are non-isolated, i.e., the input and output voltages share a common ground. There are however, isolated derivations of these non-isolated topologies. The power supply topology refer ...
OPA699: Wideband, High Gain Voltage Limiting Amplifier (Rev. B)
OPA699: Wideband, High Gain Voltage Limiting Amplifier (Rev. B)

General Description Features
General Description Features

... in series with the LED string provides wide-range dimming control. This feature provides extremely fast PWM current switching to the LEDs with no transient overvoltage or undervoltage conditions. In addition to PWM dimming, the ICs provide analog dimming using a DC input at ICTRL. The ICs sense the ...
X26c TASER® Specs Sheet - Stun Gun Defense Products
X26c TASER® Specs Sheet - Stun Gun Defense Products

... 1. Output characteristics8: Wave form: Complex shaped pulse Pulse rate: 17 pulses per second (PPS) for 2 seconds, 10 PPS thereafter for up to 30 seconds total Pulse duration: 100 microseconds The trigger activates a 10-second cycle. Second and third pull increments the cycle 10 seconds each up to 30 ...
docx
docx

Respiration Rate Measurement Using
Respiration Rate Measurement Using

... obtained with full wave rectification. For phase shifts greater than 135°, there is a likelihood of capturing the zero crossing of the signal when the block is removed. Therefore, it is better to not block the signal. It is also important to realize that with a 180° phase shift, the signal and demod ...
Multicell Converters Hybrid Sliding Mode Control
Multicell Converters Hybrid Sliding Mode Control

... Besides, modeling is a very important step for control laws and observers synthesis. As modeling accuracy depends on the required goals, one can find several model kinds for the same process and the choice among those will depend on its use and on the control objective. For the control or the observ ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE)

... (DBR) followed by a high value of the DC link capacitor feeding a voltage source inverter (VSI) based BLDC motor, draws peaky current from supply and injects a high amount of harmonics in the supply system .Therefore, power factor correction (PFC) converters are used for improving the power quality ...
the complete Kit Notes - Mini-Kits
the complete Kit Notes - Mini-Kits

... Optionally the software menu can be changed, & a 3.2MHz crystal used for 100KHz steps. 3.2MHz crystals are not a standard low cost computer type crystal so have not been used in this kit due to cost. The SP5055 is controlled & sends status information back to the 16F628 through its I2C bus connectio ...
W. Rieutort-Louis, J. Sanz Robinson, Y. Hu, L. Huang, J.C. Sturm, N. Verma, S. Wagner, "Readout from Amorphous Silicon Thin-film Transistor-based Strain Sensing Sheets over Non-contact Interfaces using a TFT Gilbert-Type Modulator", Int'l Conf. on Amorphous and Nano-crystalline Semiconductors (ICANS) (AUG 2013).
W. Rieutort-Louis, J. Sanz Robinson, Y. Hu, L. Huang, J.C. Sturm, N. Verma, S. Wagner, "Readout from Amorphous Silicon Thin-film Transistor-based Strain Sensing Sheets over Non-contact Interfaces using a TFT Gilbert-Type Modulator", Int'l Conf. on Amorphous and Nano-crystalline Semiconductors (ICANS) (AUG 2013).

Evaluates:  MAX4993 MAX4993 Evaluation Kit General Description Features
Evaluates: MAX4993 MAX4993 Evaluation Kit General Description Features

... MAX4993 DPDT analog switch in a 1.4mm x 1.8mm 10pin ultra-thin QFN package specified for operating over the -40°C to +85°C extended temperature range. The IC’s slow turn-on time provides click-and-pop reduction without additional parts in portable audio applications. The IC features low 0.3Ω RON res ...
BD9B300MUV
BD9B300MUV

... Datasheet ...
LL4148 Small Signal Diode LL4 148
LL4148 Small Signal Diode LL4 148

... cause the failure of the life support device or system, or to affect its accordance with instructions for use provided in the labeling, can be safety or effectiveness. reasonably expected to result in a significant injury of the user. ANTI-COUNTERFEITING POLICY Fairchild Semiconductor Corporation's ...
Courseware Sample Electric Power / Controls 25986-F0
Courseware Sample Electric Power / Controls 25986-F0

... the current through the resistor increases. This is also true in an AC circuit with a resistance load. If a sinusoidal voltage e is applied across a resistor R, the instantaneous variations of current i through R follow exactly the instantaneous changes in voltage e. Thus, at the instant e is going ...
How to Prevent Power Surges:  Moxa White Paper
How to Prevent Power Surges: Moxa White Paper

... Jasmine Lin Product Manager, Moxa Inc Voltage spikes are brief events that rarely last more than a few microseconds, but all it takes is one snowball to set off an avalanche. In complex systems, even seemingly small events can have serious consequences. This is definitely true of industrial automati ...
VDD! VDD! GND! GND! - University of California, Berkeley
VDD! VDD! GND! GND! - University of California, Berkeley

< 1 ... 343 344 345 346 347 348 349 350 351 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.