• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
View Uploaded Details
View Uploaded Details

... c) Wet flash-over and one-minute rain test  The insulator is sprayed with water at an angle of 45 degrees  The temp. of the water is within 10°C of the ambient temperature in the neighborhood  The insulator must withstand the test-voltage specified for one minute ...
BU21023GUL
BU21023GUL

... Please pull up the ECL, EDA, and INT pins using 10k ohm resistors as shown in the application diagram at the end of this document. ECL and EDA pins may be directly connected to GND if an external EEPROM is not being used. Please connect a 0.1µF capacitor between T4 and GND. T1, T2 & T3 pins should b ...
Rev. A - Texas Instruments
Rev. A - Texas Instruments

... timer protect the load and supply during fault conditions such as a hot - short. The fast shutdown threshold and response time can be tuned to ensure a fast response to real faults, while avoiding nuisance trips. Programmable SOA (Safe Operating Area) protection and the inrush timer keep the MOSFET ...
NCP4326 - Switchmode Power Supply Controller
NCP4326 - Switchmode Power Supply Controller

... NCP4326 provides superior performance in cross−regulation by individually regulating outputs. Powered from a main winding, the device actuates two independent switches that precisely adjust the considered outputs to resistor−selectable voltages. This controller also integrates a precision reference ...
FAN6920MR ™ Technology Integrated Critical-Mode PFC mWSaver and Quasi-Resonant Current-Mode PWM Controller
FAN6920MR ™ Technology Integrated Critical-Mode PFC mWSaver and Quasi-Resonant Current-Mode PWM Controller

... The highly integrated FAN6920MR combines Power Factor Correction (PFC) controller and quasi-resonant PWM controller. Integration provides cost-effective design and reduces external components. For PFC, FAN6920MR uses a controlled on-time technique to provide a regulated DC output voltage and to perf ...
AP7173  1.5A LOW DROPOUT LINEAR REGULATOR WITH PROGRAMMABLE SOFT-START
AP7173 1.5A LOW DROPOUT LINEAR REGULATOR WITH PROGRAMMABLE SOFT-START

... Power-Good pin, open-drain output. When the VOUT is below the PG threshold the PG pin is driven low; when the VOUT exceeds the threshold, the PG pin goes into a high-impedance state. To use the PG pin, use a 10kΩ to 1MΩ pull-up resistor to pull it up to a supply of up to 5.5V, which can be higher t ...
Loadbreaking and the Bazooms Curve
Loadbreaking and the Bazooms Curve

μ  PD166021T1F Data Sheet
μ PD166021T1F Data Sheet

... The dynamic clamp circuit works only when the inductive load is switched off. When the inductive load is switched off, the voltage of OUT falls below 0 V. The gate voltage of SW1 is then nearly equal to GND because the IS terminal is connected to GND via an external resister. Next, the voltage at th ...
Chapter 9 – DC Motors and Generators
Chapter 9 – DC Motors and Generators

... So, the result is that a differentially compounded motor is unstable and tends to run away. This instability is much worse than that of a shunt motor with armature reaction. Starting procedure must be taken care due to large armature current. So, it is almost never intentionally used for application ...
Chapter 2 - Dr. Feda A. AlShahwan
Chapter 2 - Dr. Feda A. AlShahwan

... A+ Guide to Hardware modified by Dr. Feda AlShahwan ...
Aalborg Universitet Network
Aalborg Universitet Network

HMC574MS8 数据资料DataSheet下载
HMC574MS8 数据资料DataSheet下载

... Included in the HMC-DK005 Designer’s Kit ...
Ω MAX4741/MAX4742/MAX4743 0.8 , Low-Voltage, Single-Supply Dual SPST
Ω MAX4741/MAX4742/MAX4743 0.8 , Low-Voltage, Single-Supply Dual SPST

... Note 2: The algebraic convention, where the most negative value is a minimum and the most positive value is a maximum, is used in this data sheet. Note 3: µDFN and SOT23 packaged parts are 100% tested at +25°C. Limits across the full temperature range are guaranteed by design and correlation. µMAX p ...
PS225001EN
PS225001EN

... type, wherein windings occupy each of the two limbs in order to provide balanced windings, reduce leakage current, and minimize no-load losses. 3.5. Internal secondary wiring shall be color coded and labeled for easy identification. 3.6. All regulators shall be provided with an under-oil, metal oxid ...
AP2161/ AP2171 Description Pin Assignments
AP2161/ AP2171 Description Pin Assignments

... Three possible overload conditions can occur. In the first condition, the output has been shorted to GND before the device is enabled or before VIN has been applied. The AP2161/AP2171 senses the short circuit and immediately clamps output current to a certain safe level namely ILIMIT. In the second ...
Reduced Voltage Starters Type S
Reduced Voltage Starters Type S

... values. After a set time delay the motor leads are switched to the delta connection for normal run operation. When using a wye delta starter, full voltage is applied to the motor terminals, but the effects of reduced voltage starting are the result of the way the windings are connected. Wye delta st ...
capacitor voltage transformer
capacitor voltage transformer

Bronco VFD Series Adjustable Frequency Drives
Bronco VFD Series Adjustable Frequency Drives

... or 230 VAC, 50/60 Hz, single-phase input, and is factory calibrated for an output of 0 to 60 Hz. They will operate any 1.5 HP or smaller, 208/230-volt three-phase-ACinduction, single-phase permanent split capacitor motor (see page v) and can be user calibrated for 0 through 120 Hz output. Although B ...
LT3956 - 80VIN, 80VOUT Constant-Current, Constant
LT3956 - 80VIN, 80VOUT Constant-Current, Constant

... feedback resistor. Input bias current for this pin depends on CTRL pin voltage, as shown in the Typical Performance Characteristics. ISP is an input to the short-circuit protection feature when ISN is less than 3V. VC: Transconductance Error Amplifier Output Pin. This pin is used to stabilize the vo ...
Power Distribution Systems
Power Distribution Systems

MAX14531E–MAX14534E USB 2.0 Hi-Speed and Audio Switches with General Description
MAX14531E–MAX14534E USB 2.0 Hi-Speed and Audio Switches with General Description

... signals, low/full-speed USB signals, and analog signals such as AC-coupled audio or video through any of three channels. These devices combine the low oncapacitance (CON) and low on-resistance (RON) necessary for high-performance switching applications in portable electronics, and include an interna ...
Word
Word

... type, wherein windings occupy each of the two limbs in order to provide balanced windings, reduce leakage current, and minimize no-load losses. 3.5. Internal secondary wiring shall be color coded and labeled for easy identification. 3.6. All regulators shall be provided with an under-oil, metal oxid ...
Low Voltage Performance of Multilayer Ceramic Capacitors
Low Voltage Performance of Multilayer Ceramic Capacitors

... low-impedance circuits such as for decoupling. Since these applications are at low voltages, some users have attempted to examine all low-voltage applications in terms of the high-impedance performance. The mechanism postulated for failures in low-voltage, high-impedance applications is low insulati ...
PAM2841 Description Pin Assignments
PAM2841 Description Pin Assignments

... Inductor values can have ±20% tolerance with no cur rent bias . When the inductor current approaches saturation level, its inductance can decrease 20% to 35% from the 0A value depending on how the inductor vendor defines saturation current. Using an inductor with a smaller inductance value causes di ...
1 - SEW Eurodrive
1 - SEW Eurodrive

... You can always use the MOVIDRIVE® range of units with "internal synchronous operation" whenever a group of motors has to be operated at a synchronous angle in relation to one another or with an adjustable proportional ratio (electronic gear). A user-friendly editor guides you through the startup pro ...
< 1 ... 161 162 163 164 165 166 167 168 169 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report