2SP0325T Preliminary Description & Application Manual
... Before starting up the system, it is recommended that each IGBT module be checked separately under powercycling conditions. It is usually sufficient to apply the single or double-pulse technique. CONCEPT specially recommends users to check that the IGBT modules switch inside the SOA in the worst cas ...
... Before starting up the system, it is recommended that each IGBT module be checked separately under powercycling conditions. It is usually sufficient to apply the single or double-pulse technique. CONCEPT specially recommends users to check that the IGBT modules switch inside the SOA in the worst cas ...
Shaft Generator Systems
... Shaft generators onboard ships are driven by the main engine to supply power to the mains. The mains have to be supplied with constant voltage and frequency by the shaft generator even at changing speeds of the main engine, i.e. when the vessel travels at different speed ranges or if the propeller s ...
... Shaft generators onboard ships are driven by the main engine to supply power to the mains. The mains have to be supplied with constant voltage and frequency by the shaft generator even at changing speeds of the main engine, i.e. when the vessel travels at different speed ranges or if the propeller s ...
MAX3243-EP - Texas Instruments
... (HBM) protection pin to pin (serial-port connection pins, including GND). The device meets the requirements of TIA/EIA-232-F and provides the electrical interface between an asynchronous communication controller and the serial-port connector. This combination of drivers and receivers matches that ne ...
... (HBM) protection pin to pin (serial-port connection pins, including GND). The device meets the requirements of TIA/EIA-232-F and provides the electrical interface between an asynchronous communication controller and the serial-port connector. This combination of drivers and receivers matches that ne ...
Frequency Preference Response to Oscillatory Inputs in Two
... These mechanisms can be addressed from two different, but complementary perspectives: biophysical and dynamic. The former focuses on the role of the ionic currents and their biophysical properties in shaping the neuron’s voltage response, and it has been discussed in terms of the so-called resonant ...
... These mechanisms can be addressed from two different, but complementary perspectives: biophysical and dynamic. The former focuses on the role of the ionic currents and their biophysical properties in shaping the neuron’s voltage response, and it has been discussed in terms of the so-called resonant ...
MAX5888 3.3V, 16-Bit, 500Msps High Dynamic Performance DAC with Differential LVDS Inputs
... AVDD, DVDD, VCLK to AGND................................-0.3V to +3.9V AVDD, DVDD, VCLK to DGND ...............................-0.3V to +3.9V AVDD, DVDD, VCLK to CLKGND ...........................-0.3V to +3.9V AGND, CLKGND to DGND....................................-0.3V to +0.3V DACREF, REFIO, FSA ...
... AVDD, DVDD, VCLK to AGND................................-0.3V to +3.9V AVDD, DVDD, VCLK to DGND ...............................-0.3V to +3.9V AVDD, DVDD, VCLK to CLKGND ...........................-0.3V to +3.9V AGND, CLKGND to DGND....................................-0.3V to +0.3V DACREF, REFIO, FSA ...
A simple maximum power point tracker for thermoelectric generators
... where ITEG (A) is the TEG output current. Thus, by measuring and comparing the values on the two sides of (2), the TEG operating point is progressively moved to the MPP. A voltage-trend detection circuit has been designed in [12], where the gradient of a Boost-converter output power is detected by m ...
... where ITEG (A) is the TEG output current. Thus, by measuring and comparing the values on the two sides of (2), the TEG operating point is progressively moved to the MPP. A voltage-trend detection circuit has been designed in [12], where the gradient of a Boost-converter output power is detected by m ...
electromagnetic theory - Faculty of Engineering
... INTRODUCTION: At radio frequencies (RF) and microwave frequencies, signals must be viewed as waves instead of currents and voltages. One of the reasons is the wavelength becomes very short that the current at one point of a long conductor is not the same as that at another point. As a result, the or ...
... INTRODUCTION: At radio frequencies (RF) and microwave frequencies, signals must be viewed as waves instead of currents and voltages. One of the reasons is the wavelength becomes very short that the current at one point of a long conductor is not the same as that at another point. As a result, the or ...
Manual PL512 - W-IE-NE
... transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means with the express written permission of W-Ie-Ne-R. ...
... transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means with the express written permission of W-Ie-Ne-R. ...
Solar circuit protection application guide no. 10191
... PV Strings are next connected in parallel (often by a combiner box) to increase amperage. The resulting DC power is sent to an inverter to be converted from DC to AC and then supplied to the electric grid and consumed. ...
... PV Strings are next connected in parallel (often by a combiner box) to increase amperage. The resulting DC power is sent to an inverter to be converted from DC to AC and then supplied to the electric grid and consumed. ...
MAX1280/MAX1281 400ksps/300ksps, Single-Supply, Low-Power, 8-Channel, Serial 12-Bit ADCs with Internal Reference General Description
... Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain error and offset error have been nulled. Note 3: Offset nulled. Note 4: Ground “on” channel; sine wave applied to all “off” channels. Note 5: Conversion time is defined as the number ...
... Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain error and offset error have been nulled. Note 3: Offset nulled. Note 4: Ground “on” channel; sine wave applied to all “off” channels. Note 5: Conversion time is defined as the number ...
External Reactive Power Compensation of Permanent Magnet
... power plant wind turbines. Difficult access locations and high maintenance costs require an extremely reliable operation. This could lead to encourage other generator types particularly high gearless permanent magnet synchronous generators because of their almost maintenance free and the improvement ...
... power plant wind turbines. Difficult access locations and high maintenance costs require an extremely reliable operation. This could lead to encourage other generator types particularly high gearless permanent magnet synchronous generators because of their almost maintenance free and the improvement ...
efficiency – sunlight concentration ratio
... substitutions JS1 ≡ J01(Jg/Jg1) and JSn ≡ J0n(Jg/Jgn). At the condition of generation current matching in a MJ SC, when, for example, two of ideal current sources are equivalent Jg1 = Jg2, and the potentials in sites g1 and f2 (Fig. 4) are equal to each other, the corresponding current J2 does not f ...
... substitutions JS1 ≡ J01(Jg/Jg1) and JSn ≡ J0n(Jg/Jgn). At the condition of generation current matching in a MJ SC, when, for example, two of ideal current sources are equivalent Jg1 = Jg2, and the potentials in sites g1 and f2 (Fig. 4) are equal to each other, the corresponding current J2 does not f ...
MAX1901/MAX1902/MAX1904 500kHz Multi-Output, Low-Noise Power-Supply Controllers for Notebook Computers General Description
... The MAX1901/MAX1902/MAX1904 are buck-topology, step-down, switch-mode, power-supply controllers that generate logic-supply voltages in battery-powered systems. These high-performance, dual/triple-output devices include on-board power-up sequencing, power-good signaling with delay, digital soft-start ...
... The MAX1901/MAX1902/MAX1904 are buck-topology, step-down, switch-mode, power-supply controllers that generate logic-supply voltages in battery-powered systems. These high-performance, dual/triple-output devices include on-board power-up sequencing, power-good signaling with delay, digital soft-start ...
Hammond Manufacturing Line Transformers
... quantity depends on power capacity of unit (see table below). • Rugged two piece ventilated steel enclosure. • Finished in a grey/beige color, textured powder paint with rubber feet installed. • NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have r ...
... quantity depends on power capacity of unit (see table below). • Rugged two piece ventilated steel enclosure. • Finished in a grey/beige color, textured powder paint with rubber feet installed. • NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have r ...
Application Note AN-1162 Compensator Design Procedure for Buck Converter with Voltage-Mode Error-Amplifier
... Synchronous buck converters have received great attention in low voltage DC/DC converter applications because they can offer high efficiency; provide more precise output voltage and also meet the size requirement constraints. International Rectifier Inc. has developed a series of integrated buck reg ...
... Synchronous buck converters have received great attention in low voltage DC/DC converter applications because they can offer high efficiency; provide more precise output voltage and also meet the size requirement constraints. International Rectifier Inc. has developed a series of integrated buck reg ...
PassPoint PTDCM Door Control Module
... outputs of the PassPoint PTDPSU power supply only. (Do not enable AC or Low Battery monitoring without first wiring the power supply.) DCM Relay Outputs In addition to card reader inputs, each DCM has two Form C, voltage-supervised output relays. These relays are used to operate electromagnetic door ...
... outputs of the PassPoint PTDPSU power supply only. (Do not enable AC or Low Battery monitoring without first wiring the power supply.) DCM Relay Outputs In addition to card reader inputs, each DCM has two Form C, voltage-supervised output relays. These relays are used to operate electromagnetic door ...
Introductory Circuit Analysis, Tenth Edition
... plates and the plates are 2 mm apart. 6. Repeat Problem 5 if the plates are separated by 4 mils. 7. A 4-mF parallel plate capacitor has 160 mC of charge on its plates. If the plates are 5 mm apart, find the electric field strength between the plates. 8. Find the capacitance of a parallel plate capac ...
... plates and the plates are 2 mm apart. 6. Repeat Problem 5 if the plates are separated by 4 mils. 7. A 4-mF parallel plate capacitor has 160 mC of charge on its plates. If the plates are 5 mm apart, find the electric field strength between the plates. 8. Find the capacitance of a parallel plate capac ...
Circuit Component SLAC for AXE 10
... DMG in LPA10302 enables the test program designer to define different time patterns with a high degree of flexibility. The digital real time testing is divided into test cycles. Up to 16 different cycle types can be defined simultaneously, and also mixed optionally in one and the same stream of test ...
... DMG in LPA10302 enables the test program designer to define different time patterns with a high degree of flexibility. The digital real time testing is divided into test cycles. Up to 16 different cycle types can be defined simultaneously, and also mixed optionally in one and the same stream of test ...