• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
High Voltage Direct Current Test Procedure
High Voltage Direct Current Test Procedure

... Slowly increase the voltage from 0 to 1500 volts, then to 3000 volts, and then to 4500 volts. At each step, hold for 1 minute and read the current. Record leakage current values and plot a "Leakage versus Step Voltage Curve" on a form similar to that shown in Figure 1. c) Slowly increase the voltage ...
Low Battery Indicator - Hobby Circuits and Projects
Low Battery Indicator - Hobby Circuits and Projects

... This is an ideal solution to protect rechargeable batteries from deep discharge. It gives an LED indication when the voltage level in the battery drops below5.1 volt CA 3140 Op Amp is used as a comparator with a zener to fix voltage in its non inverting input. Preset VR1 set the voltage level just b ...
Rapid Shutdown Power Supply Assemblies
Rapid Shutdown Power Supply Assemblies

... Rapid Shutdown Power Supply Assemblies SolarBOS Power Supply Assemblies are listed to UL-508A to provide power and control to combiner boxes used in PV systems. They can be configured for various input voltages and output loads, and include an external disconnect switch for remote control of contact ...
A Novel Control Strategy for Grid Connected Wind Turbines
A Novel Control Strategy for Grid Connected Wind Turbines

Maximum Power Transfer Theorem
Maximum Power Transfer Theorem

Household Appliance Monitoring System SDMay0204
Household Appliance Monitoring System SDMay0204

... User can operate a simple windows interface Computer has two available serial ports Local utility rates are known by user ...
UPS-901
UPS-901

... During normal operation, the UPS-901 shall receive a trickle charge from the associated TRX-401 unit through a balancing circuit to maintain an optimal float charge on the battery. A green LED shall indicate the presence of DC voltage in and a red LED shall indicate normal charging. In the event of ...
Manual for 3620.50/51 Power Supply
Manual for 3620.50/51 Power Supply

... This laboratory power supply can supply both direct and alternating current from 0 to 24 volts. The AC and DC sections are galvanically separated and can both be used at the same time. The supply adheres to CE-standards and is supplied with a safety transformer fulfilling EN 60742, and provided that ...
Document
Document

... replace pneumatic systems with electrical systems. Active power factor correction (PFC) rectifiers are used in MEAs to rectify the output voltage of the three-phase AC-DC boost converter, while maintaining a unity input power factor. Many existing control strategies implement PI compensators, with s ...
WEEK 1: OVERVIEW, DC CIRCUIT REVISION
WEEK 1: OVERVIEW, DC CIRCUIT REVISION

Zener diode voltage regulator File
Zener diode voltage regulator File

s - ijsetr.
s - ijsetr.

... works have dealt with a single phase PWM rectifier especially for electric traction. In [11], the authors have focused on single phase rectifier static switch failures in railway traction and in [12], the authors have investigated speed sensor FDI for induction motor drives used in electric traction ...
Basic Terms Note sheet
Basic Terms Note sheet

... • Voltage is the force that moves current, and that is the difference between the two concepts that are always confused. ...
BAT42, BAT43 Schottky Diodes FEATURES ♦
BAT42, BAT43 Schottky Diodes FEATURES ♦

... case with the type designations BAT42W to BAT43W and in the MiniMELF case with type designations LL42 to LL43. ...
.V)60 120(cos 170 )(
.V)60 120(cos 170 )(

... 9.14 A 400 Hz sinusoidal voltage with a maximum amplitude of 100 V at t = 0 is applied across the terminals of an inductor. The maximum amplitude of the steady-state current in the inductor is 25 A. a) What is the frequency of the inductor current? b) If the phase angle of the voltage is zero, what ...
Maximizing the Power Transferred to a Load Resistance in an
Maximizing the Power Transferred to a Load Resistance in an

... Because physical resistances are always positive, we conclude that we should choose the value of RL to be equal to the value of RS in order to achieve maximum power transfer to the load resistance. The plot below shows a plot of the power transferred to the load resistance as a function of the ratio ...
522 KB 1st Aug 2014 Adams Rite PS1 Power Supply
522 KB 1st Aug 2014 Adams Rite PS1 Power Supply

... devices. Output is selectable in the field for 12 or 24 VDC. Charging circuit is built in for battery backup power (batteries not included) with 12 or 24 VDC operation. LED on circuit board indicates positive power input. ...
ECGR 2255 Lab Write-Ups
ECGR 2255 Lab Write-Ups

... Obtain a 7404 TTL inverter and a CD4001 CMOS NOR gate. Select one of the inverters on the 7404 and verify that it functions properly by connecting its input to a switch and its output to an LED. Connect one of the NOR gates on the 4001 as an inverter (by grounding one of the inputs), and likewise ve ...
Design Note
Design Note

Product info PM400-800 LCD-P2
Product info PM400-800 LCD-P2

... - Compact line-interactive uninterrupted power supply with automatic voltage regulation - Protection against data losses and damage to the sensible PC equipment caused by blackouts, brownouts, peaks and surges - Built-in Smart RS-232 communication port - Controlled Shut-down function - 3 protected o ...
Aalborg Universitet
Aalborg Universitet

Sola Photovoltaics - IESL e
Sola Photovoltaics - IESL e

... This diffusion creates an electric field that leads to a drift current Ie while the movement of holes from p type and ...
7810-12
7810-12

... • Dynamic voltage scaling – since we are changing frequency, can also combine it with voltage scaling as each circuit has longer slack – has a more than quadratic effect on dynamic power, a linear effect on leakage power, and a more than linear effect on energy • Intel Xscale: roughly 50ms to scale ...
2006 VCAA Physics Exam 1 Solutions
2006 VCAA Physics Exam 1 Solutions

Inteli-PowerTM
Inteli-PowerTM

... We have selected this line of power supplies for its excellent performance, rugged durability, and near-perfect match to the requirements and demands of modern pipe organ use. ...
< 1 ... 1192 1193 1194 1195 1196 1197 1198 1199 1200 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.