• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Slide 1
Slide 1

... development of a PLC (Power Line Carrier) was achieved, using only basic components, as passive elements and logical ports. Communication is established by modulation, transmission and demodulation of the concerning data. ...
Supplement to EMC Filter Built-in Type 0.1kW to 4
Supplement to EMC Filter Built-in Type 0.1kW to 4

... 6. To comply with CSA for 200 VAC input models, transient surge suppression shall be installed on the line side of this equipment and shall be rated 240 V (phase to ground), 240 V (phase to phase), suitable for overvoltage category 3, and shall provide protection for a rated impulse withstand voltag ...
Circuit component
Circuit component

Lab 8: Series RC Circuit
Lab 8: Series RC Circuit

DC-Leistungsnetzgeräte mit Energie-Rückspeisung
DC-Leistungsnetzgeräte mit Energie-Rückspeisung

... high-voltage DC power units able to serve as either sources or loads for use in the area of battery substitution. In the automotive and automotive-supply industries these power supply units are now increasingly found in the testbeds of hybrid drives and electric vehicles. These devices can also be u ...
Voltage-controlled Oscillators (VCO), Phase Locked Loop, and
Voltage-controlled Oscillators (VCO), Phase Locked Loop, and

EK307 Lab: Introduction to Operational Amplifiers
EK307 Lab: Introduction to Operational Amplifiers

... d) Construct the potentiometer Voltage divider circuit shown in figures 1 and 2 on your breadboard. It will be used as the input for the non-inverting amplifier. A potentiometer is a variable resistance Voltage divider device. It is useful for making Voltage adjustments when you don‟t have enough a ...
Full Spec Sheet BCE Series
Full Spec Sheet BCE Series

... Advanced Conversion Products creates high performance, robust AC and DC power systems for mission critical applications in telecommunications, industrial, rapid transit, airborne, ground mobile and shipboard environments. Uninterruptible back-up power and critical system control are "the sine of per ...
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org

... voltage and status of switches/transformer taps etc. in line with interface requirements and other guideline made available by RLDC. The associated communication system to facilitate data flow up to appropriate data collection point on CTUs system, shall also be established by the concern user or ST ...
ChargeMaster 24/12-3
ChargeMaster 24/12-3

... Mastervolt's ChargeMaster guarantees fast and complete charging of your batteries no matter where you are. The ChargeMaster can charge multiple battery banks simultaneously thanks to its combined functionality. Moreover, all ChargeMasters can be easily connected to a MasterBus network with only one ...
FILTER CIRCUITS
FILTER CIRCUITS

... given frequency can be controlled by adding reactive elements - capacitors and inductors. Such circuits are usually called filters because they “filter” out frequencies except those lying in a selected range. The response of any electronic circuit depends to some degree on the frequency of operation ...
A low-voltage three-phase AC generator built from
A low-voltage three-phase AC generator built from

... phase shift since transistors are connected as emitter (or source) followers. Therefore, there is no phase shift between the input voltages of the op amp, as that expected for amplifiers with negative feedback. In this fashion, provided that an ideal op amp has an infinite differential gain, the con ...
UPS914/915
UPS914/915

... The UPS-914 and UPS-915 are high-performance UPS designed for use with WAVES® IBS, providing back-up power in the event of a loss of the normal utility power source. The UPS-914 is used for 120V systems, and the UPS-915 is used for 230V systems. In the event of a main utility power failure, the UPS ...
Design and Implementation of Energy Stored Quasi ZSI System for
Design and Implementation of Energy Stored Quasi ZSI System for

... PWM controller of each converter. The control and power management strategy followed in this research work is focused on a FPGA controller. PV and Wind energy sources are connected in parallel and controlled by a common energy management FPGA controller through their individual dc/dc converters. The ...
Electric Current
Electric Current

Dr. K.P Ray SAMEEER, Mumbai
Dr. K.P Ray SAMEEER, Mumbai

... Reactance provided by the tube capacitance Xc = j Zo tan (2/) L The length 'L' of the tuned co-axial line is given by: L = /2 tan-1 Xc / Zo Where  = wavelength in cm Xc = reactance due to the inter-electrode capacitance Zo = characteristic impedance of the line (ohm) The 50 ohm matching point t ...
Ch 3 - MyWeb at WIT
Ch 3 - MyWeb at WIT

... A dirty secret about motors When starting a motor, if the torque is not enough to start the motor, it will burn out. This low torque problem is caused by low voltages.  This problem is solved using a specially designed Buck-Boost transformer that adds or subtracts ≈ 10% to the line voltage (aka ut ...
Control for Grid Connected Small Wind Turbine System
Control for Grid Connected Small Wind Turbine System

... oscillations in the dq reference frame (Fig. 9) which are particularly high in the cases of high currents and consequently powers. It can be seen that the dq reference frame is perfectly aligned with the grid voltage vector, because all voltage appears in the d-axis. This applies only at stable volt ...
Electronics Engineering - Dronacharya College of Engineering
Electronics Engineering - Dronacharya College of Engineering

... A cycle consists of two voltage polarity reversals, current reversals, or electromagnetic field oscillations. Frequency is measured in cycles per second (cps). The unit of frequency is the hertz (Hz). ...
User Manual User Manual Hypex UcD S Hypex UcD S Hypex UcD
User Manual User Manual Hypex UcD S Hypex UcD S Hypex UcD

... The main input voltages from the transformer are wired to Faston connectors J7/J8/J9 (J22). If desired, auxiliary supply can be connected to J12/J13/J14. This low voltage, low power connection can be used for pre-amplifier use. Maximum current: 100 mA. A LED may be connected as POWER-ON indicator. T ...
Paladin Advantage Universal Programmable Transducer
Paladin Advantage Universal Programmable Transducer

Indirect Current Control Algorithm for Utility Interactive Inverters in
Indirect Current Control Algorithm for Utility Interactive Inverters in

... voltage of the DG system may become unstable because of transient phenomena. The voltage stability will be worsen when the main grid is tripped by abrupt faults such as voltage sags/swells or black out. When islanding detection is delayed by such factors as non-detection zone (NDZ), communications b ...
Switching Regulators
Switching Regulators

... unregulated input voltage, vin, through the high current switch and the filter inductor L. Therefore, if we use a transistor switch with low “ON” voltage drop in addition to a low-loss inductor, conversion efficiency of this regulator can be high (greater than 90%). The significant savings in this r ...
Home Electric Wiring
Home Electric Wiring

... The circuit breaker will cut off power to avoid the chance of a fire. ...
High Voltage Direct Current Test Procedure
High Voltage Direct Current Test Procedure

... Slowly increase the voltage from 0 to 1500 volts, then to 3000 volts, and then to 4500 volts. At each step, hold for 1 minute and read the current. Record leakage current values and plot a "Leakage versus Step Voltage Curve" on a form similar to that shown in Figure 1. c) Slowly increase the voltage ...
< 1 ... 1191 1192 1193 1194 1195 1196 1197 1198 1199 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report