• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Microwave Oven Technical File
Microwave Oven Technical File

Motor Single-Phasing Voltage Unbalance
Motor Single-Phasing Voltage Unbalance

... From the above data, it can be seen that 44% of motor failure problems are related to HEAT. Allowing a motor to reach and operate at a temperature 10°C above its maximum temperature rating will reduce the motor’s expected life by 50%. Operating at 10°C above this, the motor’s life will be reduced ag ...
Hex Level Shifter for TTL to CMOS or CMOS to CMOS
Hex Level Shifter for TTL to CMOS or CMOS to CMOS

MAX8804V/MAX8804W/MAX8804Y/MAX8804Z High-Voltage, Dual-Input, USB/AC Adapter Chargers in 2mm x 3mm TDFN General Description
MAX8804V/MAX8804W/MAX8804Y/MAX8804Z High-Voltage, Dual-Input, USB/AC Adapter Chargers in 2mm x 3mm TDFN General Description

... Note 1: Devices are 100% production tested at TA = +25°C. Limits over the operating temperature range are guaranteed by design and characterization. Note 2: VIN refers to the input for the IC. For the MAX8804V/MAX8804W/MAX8804Y/MAX8804Z, VIN is VDC with VUSB = 0V or VUSB with VDC = 0V. Note 3: Guara ...
©  U n
© U n

... To read the state of the cell, the bit lines BL and BL' are precharged typically to close to VDD, and the word line WL is activated. This turns on the access transistors, and according to the state stored in the cell, one of the bit lines will be discharged. The differential voltage or the differen ...
LT3032 Series - Dual 150mA Positive/Negative Low Noise Low
LT3032 Series - Dual 150mA Positive/Negative Low Noise Low

... of the LT3032E over the full –40°C to 125°C operating junction temperature range is assured by design, characterization, and correlation with statistical process controls. The LT3032I regulators are guaranteed over the full –40°C to 125°C operating junction temperature range. Note 3: Parasitic diode ...
FIBEROPTIC Receivers Operator`s Manual
FIBEROPTIC Receivers Operator`s Manual

... In the event that it is necessary to return any product against the above warranty, the following procedure shall be followed: a. Return authorization shall be received from the Ortel Sales Department prior to returning any device. Advise the Ortel Sales Department of the model, serial number, and t ...
FEATURES
FEATURES

... SW (Pin 3): This pin is the reference point for the floating topside gate drive circuitry. It is the common connection for the top and bottom side switches and the output inductor. This pin switches between ground and VCC with very high dv/dt rates. Care needs to be taken in the PC layout to keep th ...
TLV431 Description Pin Assignments
TLV431 Description Pin Assignments

... Figure 5 adds current limit to the series regulator in Figure 4 using a second TLV431. For currents below the limit, the circuit works normally supplying the required load current at the design voltage. However should attempts be made to exceed the design current set by the second TLV431, the device ...
Chapter 11 Shielded Metal Arc Welding Principles
Chapter 11 Shielded Metal Arc Welding Principles

... Multiple-Operator Systems • Can be installed away from work site and be connected to control panels close to welding operator • When using direct current, all welders must weld with same polarity • Most installations are d.c. • Power: 600-2,500 amperes • Cost less, saves space and cable, lowers ope ...
X WRITE REGULATED POWER SUPLY
X WRITE REGULATED POWER SUPLY

... Changes in magnetization resulting from current in this in the ZERO direction, it stores a ZERO, and yin the ONE range will result in output voltages in the sensing con state it stores a ONE. Assuming that the critical field necessary to reverse H ductor which in some cases are large enough to indic ...
rg500 series - Minarik Drives
rg500 series - Minarik Drives

... POWER APPLIED. Have a qualified electrical technician install, adjust and service this equipment. Follow the National Electrical Code and all other applicable electrical and safety codes, including the provisions of the Occupational Safety and Health Act (OSHA), when installing equipment. • Reduce ...
PAM2421/ PAM2422/ PAM2423 Description Pin Assignments
PAM2421/ PAM2422/ PAM2423 Description Pin Assignments

... Rectifier Selection For optimal performance, the rectifier should be a Schottky rectifier that is rated to handle both the output voltage as well as the peak switch current. ...
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application
Comanche Peak Nuclear Power Plant, Units 3 & 4 COL Application

... Johnson lines are in control house #1, and those for the Parker and the Whitney lines are in control house #2. The transmission lines that are associated with different control houses are designed such that, availability of the two lines associated with one control house is not lost by any single fa ...
jhjds2012s
jhjds2012s

Circuit-Test Test Equip Catalog
Circuit-Test Test Equip Catalog

... All product listings, specifications, availability and pricing are subject to change without notice. While we strive to have our catalog accurate and error-free, we can not be liable for typographical errors and omissions. Please see our website for most current product information. NOTE: Some of the ...
SiC-Diodes, SiC-MOSFETs and Gate Driver IC
SiC-Diodes, SiC-MOSFETs and Gate Driver IC

... temperature -40°C – +125°C and industries best common mode noise immunity of 100kV/us which makes them a perfect suitable to switch fast SiC devices. BM6105FW for example is pin-to-pin compatible to competitors solution. The drivers are originally designed for high side but since some customers are ...
BD00IA5MEFJ-LB
BD00IA5MEFJ-LB

... An excess in the absolute maximum ratings, such as supply voltage, temperature range of operating conditions, etc., can break down the devices, thus making impossible to identify breaking mode, such as a short circuit or an open circuit. If any over rated values will expect to exceed the absolute ma ...
Analsysis of CT and Clamp-on Response to Motor Starting Waveform
Analsysis of CT and Clamp-on Response to Motor Starting Waveform

CI23521526
CI23521526

... This paper presents novel concept of a multiple converter. It works in three modes- AC-AC converter voltage regulator, AC-AC converter frequency changer and AC-DC converter. All three modes work simultaneously. AC-AC converter mode of operation alters low input frequency to high output frequency acr ...
Design of a proper set-up for low current
Design of a proper set-up for low current

... Low-level measurements are an important part of electrical studies. Due to the small values of current and voltage used, the precision of the values becomes very important. For example, a change of 1 nA or 1 nV can make a huge difference. For that reason, measuring those values requires special stud ...
RRR040P03
RRR040P03

... Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fi ...
Switching Control Technique of Phase-Shift- Controlled Full
Switching Control Technique of Phase-Shift- Controlled Full

... 3) A small inductor and large capacitor are added to generate a constant voltage source on secondary side, as proposed in [10]. Although the circulating current is reduced and the zero-current switching (ZCS) is achieved by leading leg of full-bridge converter, this will prevent the leading leg from ...
fr-a802 (separated converter type) instruction manual (hardware)
fr-a802 (separated converter type) instruction manual (hardware)

Specification Guide
Specification Guide

... the ability to operate from –16L to +16R in less than 10 seconds. 2.2.3. An electrical feedback circuit shall be incorporated with the tap-changer motor circuit and control to ensure accurate indication of tap position and number of operations. Accuracy is to be maintained for all dielectric fluids ...
< 1 ... 106 107 108 109 110 111 112 113 114 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report