• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
B-138 Series, Rated up to 60 Amps, 115/200 VAC, 400... HARTMAN Power Switching AC Contactors Product Facts
B-138 Series, Rated up to 60 Amps, 115/200 VAC, 400... HARTMAN Power Switching AC Contactors Product Facts

... All Circuits to Ground — 1,500 Vrms Circuit to Circuit — 1,500 Vrms Coil to Ground and Aux. Contacts — ...
Solving high-voltage off-line HB-LED constant-current control
Solving high-voltage off-line HB-LED constant-current control

... Table 2: Experimental results with 12 HB-LEDS (two LUXEON flood 25-0032 boards) @ 350. mA Figures 2 and 3 indicate slightly worse ripple for higher input voltages as theory predicts, owing to the correspondingly small duty cycle. This suggests better performance in low mains-voltage regions such as ...
ILSCOPedia \ Electrical Industry Terminology
ILSCOPedia \ Electrical Industry Terminology

... rod with the copper metallurgically bonded to an aluminum core. The copper forms a minimum of 10 percent of the cross-sectional area of a solid conductor or each strand of a stranded conductor. CORONA - Phenomenon associated with all transmission lines. Under certain conditions, the localized electr ...
DSL  Primary Switched Battery Charging and Power Supply Unit GL0524
DSL Primary Switched Battery Charging and Power Supply Unit GL0524

600 V, 1.0 A Power Rectifier
600 V, 1.0 A Power Rectifier

... high-quality high-reliability products and recommends adopting safety measures when designing equipment to avoid accidents or malfunctions. Such measures include but are not limited to protective circuits and error prevention circuits for safe design, redundant design, and structural design. "Typica ...


... 1) Calculate the two break frequencies using the given values. Measure the two break frequencies by finding the points where v0 / vi  0.7 . Section 5.6 of GIL provides further instructions if needed. Although any amplitude input signal can be used a good recommended signal is 10 V (p-p). The measur ...
Hazards in the home from mains electricity Hazards can include: 1
Hazards in the home from mains electricity Hazards can include: 1

... metal case, then because the case is earthed, a big current flows in through the live, through the case and out down the earth wire. This surge in current blows the fuse (or trips the circuit breaker), which cuts off the live supply. This isolates the whole appliance making it impossible to get an e ...
to notes
to notes

... and protection devices are used on the low side, but substations supplying large amounts of load may have protection devices on both sides of the transformer. Special substation designs to achieve high reliability may utilize multiple circuit breakers, as shown in Fig. 1. Less expensive designs may ...
How to Efficiently Boost Power in High Voltage Automotive
How to Efficiently Boost Power in High Voltage Automotive

LA4500
LA4500

... semiconductor products fail with some probability. It is possible that these probabilistic failures could give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire, or that could cause damage to other property. When designing equipment, adopt safety meas ...
Current Model Buck Converter Example LM3495 LM5576
Current Model Buck Converter Example LM3495 LM5576

Sampling And Averaging Considerations For Measuring Input Power
Sampling And Averaging Considerations For Measuring Input Power

2011 Power Factor Calculation by the Finite Element Method CN62
2011 Power Factor Calculation by the Finite Element Method CN62

... Power Factor Calculation by The Finite Element Method. (continued) Motor designers sometimes use the direct model to estimate the power factor. In this model the time of passage by zero is taken directly from curves obtained in simulations. This model should not be used when waveforms are charged of ...
Linear Integrated Circuits
Linear Integrated Circuits

II. MOS-NDR Device and Inverter DESIGN
II. MOS-NDR Device and Inverter DESIGN

... advantages, and they may have high potential as functional devices due to their unique folding I-V characteristics. However these RTD devices are fabricated by the compound semiconductor and process. Therefore this kind of NDR device is difficult to combine with other devices and circuits to achieve ...
dc/dc converter
dc/dc converter

Stereo Phono/Line Preamplifier Ultra 4B SE Special Edition User’s Manual
Stereo Phono/Line Preamplifier Ultra 4B SE Special Edition User’s Manual

... amplifier configuration giving a gain of around 22 dB. This stage is biased by a lightemitting diode (LED) which provides the required dc bias voltage while presenting a low resistance to signals. This eliminates the necessity of an electrolytic cathode resistor bypass capacitor. The output of this ...
NCP1090GEVB, NCP1094GEVB Power-over-Ethernet PD Interface Evaluation Board
NCP1090GEVB, NCP1094GEVB Power-over-Ethernet PD Interface Evaluation Board

... The evaluation boards consist of different sections that will be described in detail in the next paragraphs. First, we will discuss the input section, including selection of the correct connectors, magnetics and the termination for a Power-over-Ethernet enabled connection. In the next section we wil ...
Glossary for Wind Farm Power Station Grid Code Provisions
Glossary for Wind Farm Power Station Grid Code Provisions

... A device that collects, codes and transmits data. An RTU collects information from a master device and implements processes that are directed by that master. RTUs are equipped with input channels for sensing or Metering, output channels for control, indication or alarms and a communications port. ...
GLC75, GLM75 - SL Power Electronics
GLC75, GLM75 - SL Power Electronics

... Internal ac fuse provided. Designed to blow only if a catastrophic failure occurs in the unit—fuse does not blow on overload or short circuit. ...
open circuit test
open circuit test

CH 21 - AC Circuits and Electromagnetic Waves
CH 21 - AC Circuits and Electromagnetic Waves

... A transformer consists of two coils which are closely coupled so that the flux generated by one coil (the primary) passes mostly through the other coil (the secondary). The flux coupling can be made nearly complete if the coils are wound around an easily magnetizable core such as iron. ...
FM radio circuit
FM radio circuit

... The IC has an FLL (Frequency-Locked-Loop) system with an intermediate frequency of 70 kHz. The i.f. selectivity is obtained by active RC filters. The only function which needs alignment is the resonant circuit for the oscillator, thus selecting the reception frequency. Spurious reception is avoided ...
Glossary of Terms - Advanced Protection Technologies
Glossary of Terms - Advanced Protection Technologies

... Open-circuit voltage (OCV) - The voltage available from the test set up (surge generator, coupling circuit, back filter, connecting leads) at the terminals where the surge protective device (SPD) under test will be connected. (SC definition) Oscillatory transient - A power quality term that describe ...
Optically addressable field effect nano- environments for chemical imaging
Optically addressable field effect nano- environments for chemical imaging

... figure, also indicating the approximate size of the illuminating beam. Contrast in Fig. 2a is determined by differences of amplitude in the u(V) characteristic, which correspond to optical modulations of the photocurrent generation when the beam is masked thought the Al grid and the Pd films. A larg ...
< 1 ... 1058 1059 1060 1061 1062 1063 1064 1065 1066 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report