• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ELECTRICAL CIRCUITS
ELECTRICAL CIRCUITS

... When the switch is closed, the lamp lights up. This is because there is a continuous path of metal for the electric current to flow around. ...
An Operational Transconductance Amplifier (OTA) Sample-and-Hold Phys 3610/6610 Lab 22 Student: TA:
An Operational Transconductance Amplifier (OTA) Sample-and-Hold Phys 3610/6610 Lab 22 Student: TA:

... signal. The signal to be sampled will be a 60 Hz triangular wave of 1 V peak-to-peak amplitude. You can use the signal generators in the lab to make this signal, or generate it yourself from the 60 Hz square wave and either an op-amp integrator (with no DC response) or a long RC time constant circui ...
MT3 Interfacing light-emitting diodes (LEDs) and push buttons to the
MT3 Interfacing light-emitting diodes (LEDs) and push buttons to the

... When the switch is closed or opened, the switch contacts bounces against each other before settling. Sometimes the microcontroller picks this up as bouncing noise. This could lead to undesirable conditions. For example the microcontroller may receive multiple triggers even when the button is pressed ...
DC Current Transducer DK-B020 I = 50 .. 200 A
DC Current Transducer DK-B020 I = 50 .. 200 A

Zen Variations 8
Zen Variations 8

... designers linearize the tube circuit by operating the voltage/current load line so as to get some cancellation between competing voltage and current distortion. This can be done with either single-ended or push-pull circuits. The guys with pentode type devices, which includes solid state as well as ...
MTR_Pedro_WP2 - Indico
MTR_Pedro_WP2 - Indico

...  Avoids a large waist of silicon area since only one counter is used. Disadvantages  fabrication’s process dependent, because gate delays are PVT sensitive.  Large measurement uncertainty Solution  Replace all the delays by a single delay in each path, the circuit will be almost independent of t ...
Photovoltaic Solar System Components
Photovoltaic Solar System Components

... Other Mounting Systems? • If it is impossible or you don’t want to put a PV system on your existing roof, it is possible to pole mount the arrays somewhere near the house as long as the solar exposure is good. • Pole mounted solar arrays also have the potential to rotate to follow the sun over the ...
PDF Print Version - Glassman High Voltage
PDF Print Version - Glassman High Voltage

... from short circuit to rated voltage at any load condition. Voltage Monitor: 0 to +10 V equivalent to 0 to rated voltage. Accuracy: 0.5% of reading + 0.2% of rated. Impedance is 10 KΩ. Current Monitor: 0 to +10 V equivalent to 0 to rated current. Accuracy: 1% of reading + 0.1% of rated. Impedance is ...
2SD2671
2SD2671

... No technical content pages of this document may be reproduced in any form or transmitted by any means without prior permission of ROHM CO.,LTD. The contents described herein are subject to change without notice. The specifications for the product described in this document are for reference only. Up ...
photovoltaic solar cell - e
photovoltaic solar cell - e

Lab 4 - ece.unm.edu
Lab 4 - ece.unm.edu

DC current transducer DK-B420 B IPN = 150 .. 400 A
DC current transducer DK-B420 B IPN = 150 .. 400 A

... In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly! Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the tec ...
Physics 196 Lab 15: AM Radio Receiver Equipment: Layouts:
Physics 196 Lab 15: AM Radio Receiver Equipment: Layouts:

... to a 1 kHz, 1V peak square wave, and observe the voltage across the capacitor with the oscilloscope. You should be able to see voltage oscillations on the oscilloscope when the function generator switches. For instance, in the oscilloscope trace below the horizontal scale is 500 ns per division, and ...
Single Electron Devices
Single Electron Devices

BA4101300306
BA4101300306

Datasheet - Littelfuse
Datasheet - Littelfuse

... protected. In this situation, there is a time delay associated with the capacitance of the device and an overshoot condition associated with the inductance of the device and the inductance of the connection method. The capacitive effect is of minor importance in the parallel protection scheme becaus ...
Wires and Cables document
Wires and Cables document

LOW VOLTAGE MAIN AND SUBMAIN ELECTRICAL DISTRIBUTION
LOW VOLTAGE MAIN AND SUBMAIN ELECTRICAL DISTRIBUTION

... LOW VOLTAGE MAIN AND SUBMAIN ELECTRICAL DISTRIBUTION ...
Power quality monitoring and analysis with
Power quality monitoring and analysis with

... >>Flicker measurement and trending (CM4000T): measures, trends voltage flicker according to IEC 61000-4-15 standard >>Interharmonics measurement (CM4250): measures interharmonics that can adversely affect equipment >>Waveshape alarm: detects and captures sub-cycle events that do not exceed the thres ...
Electrical Systems and Construction Student`s Book
Electrical Systems and Construction Student`s Book

... such as hospitals. Multiple lines between points on the network are provided so that power can be routed from any power plant to any load centre, through a variety of routes, based on the economics of the transmission path and the cost of power. Much analysis is done to determine the maximum reliabl ...
E a
E a

... variable resistance in series with the armature Potential divider control : If the speed control from zero to the rated speed is required , by rheostatic method then the voltage across the armature can be varied by connecting rheostat in a potential divider arrangement . ...
Electric Snowmobile - University of New Hampshire
Electric Snowmobile - University of New Hampshire

Krell Audio Components KCT
Krell Audio Components KCT

PM100 and PM150 Family Propulsion Inverters
PM100 and PM150 Family Propulsion Inverters

... IEC61000 / FCC Part 15 Class B, pending ...
Common-mode transient immunity for isolated
Common-mode transient immunity for isolated

... operate at 50 kHz to 200 kHz. Some advantages for using a higher switching frequency are smaller filter size, fast control and lower distortion. However, these advantages come with an increased power loss during transition. Common-mode transient immunity (CMTI) is an important parameter of a gate dr ...
< 1 ... 1056 1057 1058 1059 1060 1061 1062 1063 1064 ... 1265 >

Islanding

Islanding refers to the condition in which a distributed generator (DG) continues to power a location even though electrical grid power from the electric utility is no longer present. Islanding can be dangerous to utility workers, who may not realize that a circuit is still powered, and it may prevent automatic re-connection of devices. For that reason, distributed generators must detect islanding and immediately stop producing power; this is referred to as anti-islanding.The common example of islanding is a grid supply line that has solar panels attached to it. In the case of a blackout, the solar panels will continue to deliver power as long as irradiance is sufficient. In this case, the supply line becomes an ""island"" with power surrounded by a ""sea"" of unpowered lines. For this reason, solar inverters that are designed to supply power to the grid are generally required to have some sort of automatic anti-islanding circuitry in them.In intentional islanding, the generator disconnects from the grid, and forces the distributed generator to power the local circuit. This is often used as a power backup system for buildings that normally sell their excess power to the grid.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report