INA131 数据资料 dataSheet 下载
... The input impedance of the INA131 is extremely high— approximately 1010Ω. However, a path must be provided for the input bias current of both inputs. This input bias current is typically less than ±1nA (it can be either polarity due to cancellation circuitry). High input impedance means that this in ...
... The input impedance of the INA131 is extremely high— approximately 1010Ω. However, a path must be provided for the input bias current of both inputs. This input bias current is typically less than ±1nA (it can be either polarity due to cancellation circuitry). High input impedance means that this in ...
Practical Problems
... secondary winding. The mean length of the magnetic path in the core is 150 cm and the joints are equivalent to an air-gap of 0.1 mm. When a potential difference of 3000 V is applied to the primary, maximum flux density is 1.2 T. Calculate : ...
... secondary winding. The mean length of the magnetic path in the core is 150 cm and the joints are equivalent to an air-gap of 0.1 mm. When a potential difference of 3000 V is applied to the primary, maximum flux density is 1.2 T. Calculate : ...
103_unit_5
... The oscilloscope is used to measure the amplitude of a voltage, displayed on the vertical axis, against time, which is displayed on the horizontal axis. The vertical and horizontal axis have marked graduated scales, in each direction, calibrated into major and minor divisions. A range switch, in con ...
... The oscilloscope is used to measure the amplitude of a voltage, displayed on the vertical axis, against time, which is displayed on the horizontal axis. The vertical and horizontal axis have marked graduated scales, in each direction, calibrated into major and minor divisions. A range switch, in con ...
Compliance Voltage
... voltage needed to perform an experiment in this cell with this electrolyte. The experiment was repeated, but this time using the isolated counter-electrode kit shown in Figure 3. The data are presented in Figure 4, and also shown as the red curves in Figure 2. From Figure 2, we see that the familiar ...
... voltage needed to perform an experiment in this cell with this electrolyte. The experiment was repeated, but this time using the isolated counter-electrode kit shown in Figure 3. The data are presented in Figure 4, and also shown as the red curves in Figure 2. From Figure 2, we see that the familiar ...
BFP405F
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
... Due to technical requirements, components may contain dangerous substances. For information on the types in question, please contact the nearest Infineon Technologies Office. Infineon Technologies components may be used in life-support devices or systems only with the express written approval of Inf ...
Discrete Input Source and Isolated Modules
... The source module provides a source voltage for dry relay contacts or for an open-collector solid-state switch. The isolated module accepts an external voltage from a powered two-state device while maintaining electrical isolation from the ROC power supplies. ...
... The source module provides a source voltage for dry relay contacts or for an open-collector solid-state switch. The isolated module accepts an external voltage from a powered two-state device while maintaining electrical isolation from the ROC power supplies. ...
Information for Product: #ACL 385
... This product has been produced using 1% meta film resistors, and high speed OP-AMP Integrated circuits. The calibration procedure is based upon the product being of linear technology. The changeover points are determined on resistance and are ??decade on a logarithmic scale i.e. (3.16 x 10n). The li ...
... This product has been produced using 1% meta film resistors, and high speed OP-AMP Integrated circuits. The calibration procedure is based upon the product being of linear technology. The changeover points are determined on resistance and are ??decade on a logarithmic scale i.e. (3.16 x 10n). The li ...
Qucs - A Tutorial
... and VBE . Although these factors are useful, comparing bias circuits and biasresistor values requires tedious calculations. A visual presentation that compares the stability of the various circuits is more useful. Looking at the equation for IC in Figure 1b, note that much of the change in IC is due ...
... and VBE . Although these factors are useful, comparing bias circuits and biasresistor values requires tedious calculations. A visual presentation that compares the stability of the various circuits is more useful. Looking at the equation for IC in Figure 1b, note that much of the change in IC is due ...
Lecture 1 - Ilam university
... attempt to amplify the small output signal of the microphone. Unfortunately, there is no DC bias current running through the transistor to set the transconductance. ...
... attempt to amplify the small output signal of the microphone. Unfortunately, there is no DC bias current running through the transistor to set the transconductance. ...
84st_q
... heard. When the loudspeaker L2 is temporarily disconnected, a student finds that the intensity of the sound heard at Z increases. He finds this difficult to understand, as disconnecting L2 presumably means that the total output energy from the loudspeakers decreases. Write a short note explaining th ...
... heard. When the loudspeaker L2 is temporarily disconnected, a student finds that the intensity of the sound heard at Z increases. He finds this difficult to understand, as disconnecting L2 presumably means that the total output energy from the loudspeakers decreases. Write a short note explaining th ...
High Voltage Current Shunt Monitor AD8212
... The base of the external PNP, Q2, is connected to ALPHA (Pin 6) of the AD8212. The current flowing in this path is mirrored inside the current compensation circuit. This current then flows in Resistor R2, which is the same value as Resistor R1. The voltage created by this current across Resistor R2, ...
... The base of the external PNP, Q2, is connected to ALPHA (Pin 6) of the AD8212. The current flowing in this path is mirrored inside the current compensation circuit. This current then flows in Resistor R2, which is the same value as Resistor R1. The voltage created by this current across Resistor R2, ...
Using Forward Voltage to Measure Semiconductor Junction
... make high brightness LED’s possible, are all susceptible to early failure due to increased heat. This becomes an even larger issue when feature size shrinks and current requirements increase. Even normal operation can cause heat build up, raising the junction temperature. These elevated temperatures ...
... make high brightness LED’s possible, are all susceptible to early failure due to increased heat. This becomes an even larger issue when feature size shrinks and current requirements increase. Even normal operation can cause heat build up, raising the junction temperature. These elevated temperatures ...
Introduction - facstaff.bucknell.edu
... usually represented by some particular nonzero (typically positive) voltage value. Input voltage v0 represents the least significant bit (LSB), v1 the second bit, and v2 the most significant bit (MSB). The input resistors R0 through R2 must be chosen so that a change in state in the bit applied to a ...
... usually represented by some particular nonzero (typically positive) voltage value. Input voltage v0 represents the least significant bit (LSB), v1 the second bit, and v2 the most significant bit (MSB). The input resistors R0 through R2 must be chosen so that a change in state in the bit applied to a ...
Engineering Science EAB_S_127_Ch4
... time, until after a long time, the capacitor will have the same voltage as the supply,V ...
... time, until after a long time, the capacitor will have the same voltage as the supply,V ...
linear detection wire
... mechanically resistant and reliable detection system that detects heat anywhere along its length. Due to its ease of installation, space saving design and low cost the Dafo Detection Wire is an excellent choice in Buses, Construction Machinery, Off-Road Vehicles, Conveyors & Cable Trays. The wire co ...
... mechanically resistant and reliable detection system that detects heat anywhere along its length. Due to its ease of installation, space saving design and low cost the Dafo Detection Wire is an excellent choice in Buses, Construction Machinery, Off-Road Vehicles, Conveyors & Cable Trays. The wire co ...
Return voltage measurements Diagnostic interpretations based on
... In dependence on the actual structure of the distribution network, various lengths of cable segments are to be measured and hence the capacitance Cp and the resistance Rp of the measured cable sections are different. In principle, the return voltage curve does not depend on the length of a measured ...
... In dependence on the actual structure of the distribution network, various lengths of cable segments are to be measured and hence the capacitance Cp and the resistance Rp of the measured cable sections are different. In principle, the return voltage curve does not depend on the length of a measured ...
Lecture notes-in-progress for the "Electromechanical grid"
... the frequency of the sinusoidal current and lf t is the series inductance of the line. We will neglect the shunt charging elements jB/2 in the π model. r and x can be combined to form a complex√impedance zf t = rf t + jxf t , in which (by electrical engineering notational tradition) j = −1. The inve ...
... the frequency of the sinusoidal current and lf t is the series inductance of the line. We will neglect the shunt charging elements jB/2 in the π model. r and x can be combined to form a complex√impedance zf t = rf t + jxf t , in which (by electrical engineering notational tradition) j = −1. The inve ...
Tube Town – Bias Setup
... What is bias adjustement? Tubes are components which are subject to a certain amount of wear and tear. They don't work forever at full power and 100% reliability; rather, they deteriorate with time. Because of the way they are constructed, they can fail completely; for example, due to a broken fila ...
... What is bias adjustement? Tubes are components which are subject to a certain amount of wear and tear. They don't work forever at full power and 100% reliability; rather, they deteriorate with time. Because of the way they are constructed, they can fail completely; for example, due to a broken fila ...