• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Constant Voltage Sinusoidal Transformers Operating and Service
Constant Voltage Sinusoidal Transformers Operating and Service

... It is desirable to have a switch in the input circuitry for turning off power to the unit when it is not in use. While all CVS transformers are designed for continuous duty, they draw appreciable current regardless of output loading. The outputs of all Sola/Hevi-Duty standard CVS transformers are is ...
What is LDO (Low-Dropout Voltage Regulator) 2006/6  John Wu 吳旻翰
What is LDO (Low-Dropout Voltage Regulator) 2006/6 John Wu 吳旻翰

... (A) “Classic” NPN-based regulators that require 2.5 to 3V of excess input voltage to function.7805,317,340 (B) “Low Dropout NPN” regulators, with a NPN output but a PNP base drive circuit. These devices reduce the dropout requirement to 1.2 to 1.5V. (C) True low dropout PNP-based regulators that nee ...
here - Transaction on electrical engineering
here - Transaction on electrical engineering

PHY 167 - Lehman College
PHY 167 - Lehman College

... measurement is, while an error is the discrepancy between the measured value of some quantity and its true value. Errors in measurements arise from different sources: a) A common type of error is a blunder due to carelessness in making a measurement, for example an incorrect reading of an instrument ...
MAX8814 28V Linear Li+ Battery Charger with Smart Autoboot Assistant General Description
MAX8814 28V Linear Li+ Battery Charger with Smart Autoboot Assistant General Description

... The MAX8814 contains an autobooting assistant circuit that generates an enable signal for system booting (ABO). The booting assistant functions as an internal “OR” gate (Figure 1). The first input is dependent on the input voltage (V IN), and the second input is an external signal applied to ABI. Th ...
NCP3065, NCV3065 Up to 1.5 A Constant Current Switching Regulator for LEDs
NCP3065, NCV3065 Up to 1.5 A Constant Current Switching Regulator for LEDs

... Vin − Nominal operating input voltage. Vout − Desired output voltage. Iout − Desired output current. DIL − Desired peak−to−peak inductor ripple current. For maximum output current it is suggested that DIL be chosen to be less than 10% of the average inductor current IL(avg). This will help prevent I ...
Beta Rollff & Avalanche Breakdown
Beta Rollff & Avalanche Breakdown

FST3345 — 8-Bit Bus Switch Features Description 
FST3345 — 8-Bit Bus Switch Features Description 

... Stresses exceeding the absolute maximum ratings may damage the device. The device may not function or be operable above the recommended operating conditions and stressing the parts to these levels is not recommended. In addition, extended exposure to stresses above the recommended operating conditi ...
Motor and Pump Protection
Motor and Pump Protection

... monitor or directly to a computer or PLC. The RM-2000/777 motor management system combines unsurpassed electronic motor protection and critical, user friendly motor monitoring. SymCom's Solutions Software (sold separately) can be used to monitor and control up to 99 Model 777s from a central compute ...
Design Calculation of Voltage Transformer 66kV Line In 230/66
Design Calculation of Voltage Transformer 66kV Line In 230/66

... measuring instruments, protective relays and control circuits. Instrument transformers are designed to transform voltage or current from the high values in the transmission and distribution systems to low values that can be utilized by low voltage metering devices. Instrument transformers are used; ...
DE31726728
DE31726728

... This paper presents another approach for PLL technique for synchronization of single-phase on-grid inverter with the public grid. Its PD block operation is based on sinus and cosines transformations of the voltage of the inverter and a reference voltage signal which is the grid voltage. This paper i ...
Lenz and Inductors
Lenz and Inductors

TR41.9.1-06-11-004- Proposed Revisions to TIA-968
TR41.9.1-06-11-004- Proposed Revisions to TIA-968

... signal level control shall provide not exceed the programmed levels given in Table 4.5 within +/1 dB. The voltages impressed on resistor Rp by the data equipment shall be such as not to cause power dissipation in Rp in excess of 50 milliwatts. The circuit shown below was used in calculating values o ...
Analog circuits using FinFETs
Analog circuits using FinFETs

... bandwidths. To reach a high gm /ID ratio VGS is typically set to values in the range of 50 mV–300 mV above VT leading to quite low current densities. Next the impact of SH on comparator circuits is shown. A simple comparator structure with differential input stage, MOS diode loads and common source ...
Complex Resistor Combinations
Complex Resistor Combinations

... circuit into groups of series and parallel resistors. This way, the methods presented in Sample Problems A and B can be used to calculate the equivalent resistance for each group. ...


... A passive component, depending on field, may be either a component that consumes (but does not produce) energy or a component that is incapable of power gain . The passive circuit elements resistance R, inductance L and capacitance C are defined by the manner in which voltage and current are related ...
AP6502A Description Pin Assignments
AP6502A Description Pin Assignments

... When the HS MOSFET is on, inductor current starts to increase. The current sense amplifier senses and amplifies the inductor current. Since the current mode control is subject to sub-harmonic oscillations that peak at half the switching frequency, ramp slope compensation is utilized. This will help ...
Chapter 21: Electric Charge and Electric Field
Chapter 21: Electric Charge and Electric Field

Aalborg Universitet Wind Power Conversion System
Aalborg Universitet Wind Power Conversion System

... Since the inverter operates as a voltage source, its interconnection to the grid is performed by means of an LCLfilter, which was designed based on [10]. The main aim of the filter is to mitigate the harmonic content [11], especially in the high frequency (HF) range of the spectrum, and also to prov ...
typical performance curves (cont)
typical performance curves (cont)

... Difet fabrication of the OPA627/637 provides very low input bias current. Since the gate current of a FET doubles approximately every 10°C, to achieve lowest input bias current, the die temperature should be kept as low as possible. The high speed and therefore higher quiescent current of the OPA627 ...
09-WATTMETER
09-WATTMETER

... This coil has a highvalue resistor connected in series with it to reduce the current that flows through it and make the voltage-coil circuit of the meter as purely resistive as possible. As a result, current in the voltage circuit is practically in phase with line voltage. ...
STL24NM60N
STL24NM60N

... The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. ...
led built-in modules
led built-in modules

E044043336
E044043336

... the output of the IGBT to obtain the load voltage THD within the limits. A notch filter to remove the harmonics and a low pass filter for the fundamental component are used as shown in Fig. 1. Capacitor Cr1 in combination with source inductance and leakage inductance form the low pass filter. The no ...
File - Teacher Plant
File - Teacher Plant

... conductor can be shown by sprinkling iron filings or arranging magnetic compasses around the conductor  The compasses line up with the magnetic field (a pattern of ...
< 1 ... 726 727 728 729 730 731 732 733 734 ... 1601 >

Ohm's law

  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report