• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Datasheet TOE 8951 to TOE 8952
Datasheet TOE 8951 to TOE 8952

... parameters and operating functions even after many years of use. Display The set and measured values for voltage, current and power as well as the menu control functions are output on a 2-row LCD with 20 characters/row. Highest degree of safety is guaranteed for your applications by comprehensive pr ...
Page 1 of 12
Page 1 of 12

Residual current devices in LV
Residual current devices in LV

... (diastole and systole). The flow of AC current through the body may be responsible for this due to the periodic excitation that it generates. The ultimate consequence is stoppage of blood flow. Direct contact: Contact of a person with the live parts of electrical devices (normally energised parts an ...
Torque Wrenches - Motorq
Torque Wrenches - Motorq

... Torque Wrenches - Handitorq ‘Handitorq’ Torque Wrench Range A new range of competitively priced Torque Wrenches, designed for the automotive market. Ideal for Tyre Shops and Fast-Fits, these Torque Wrenches are designed for that sector of the market where economy is important, but are still manufact ...
Motor Parameters Application Note
Motor Parameters Application Note

... Care must be taken when using equipment to measure motor voltage and/or current values. There are many different ways to report these values (for example, peak of sine or RMS of sine) and the results can be very confusing or misleading if the correct formulation is not known. The relationships deriv ...
HGTG30N60A4 600V SMPS IGBT Features
HGTG30N60A4 600V SMPS IGBT Features

... Deadtime (the denominator) has been arbitrarily held to 10% of the on-state time for a 50% duty factor. Other definitions are possible. td(OFF)I and td(ON)I are defined in Figure 21. Device turn-off delay can establish an additional frequency limiting condition for an application other than TJM. ...
Chapter 8
Chapter 8

... pastes on AlN, to avoid flaking off during the high temperature processing. BeO has even higher thermal conductivity than AlN. However, its use is limited by the fact that dust and vapour from BeO are very poisonous. High price is also connected to this fact. For high volume products with lower elec ...
Improved Deadbeat Current Controller with a Repetitive
Improved Deadbeat Current Controller with a Repetitive

... the output by delaying N sampling periods as shown in Fig.5. Therefore, repetitive control is often combined with deadbeat control or proportional-integral control to improve its dynamic performance when it is applied directive in the current loop controller. Even so, the dynamic performance is not ...
MAX5174/MAX5176 General Description Features
MAX5174/MAX5176 General Description Features

... typical supply current to 1µA. Enter shutdown by writing the appropriate input-control word as shown in Table 1 or by using the hardware shutdown. In shutdown mode, the reference input and amplifier output both become high impedance, and the serial interface remains active. Data in the input registe ...
Input and Output Capacitor Selection
Input and Output Capacitor Selection

Input and Output Capacitor Selection
Input and Output Capacitor Selection

AN#49
AN#49

... (EIS) measurements are more often performed under potentiostatic control than under galvanostatic control. In most cases, potentio and galvano modes are equivalent (PEIS or GEIS techniques, in EC-Lab® software) and result in the same impedance diagrams provided that a sine current amplitude is “equi ...
Power Factor Measurement
Power Factor Measurement

Mutual Inductance Self-Inductance Energy stored in a magnetic field
Mutual Inductance Self-Inductance Energy stored in a magnetic field

PSCAD/EMTDC Simulation of Powe
PSCAD/EMTDC Simulation of Powe

... represents a typical distribution network with several hundred nodes spread along the main feeder and lateral but only the node supplying the most critical customer need to be examined. The equivalent transmission system consists of three 150-kV lines and is relatively of large size(800-km total len ...
chapter 1 operational amplifier
chapter 1 operational amplifier

MAX5951 12V/5V Input Buck PWM Controller General Description Features
MAX5951 12V/5V Input Buck PWM Controller General Description Features

... step-down, DC-DC controller. The device operates over the input-voltage range of 8V to 16V or 5V ±10%, and provides an adjustable output from 0.8V to 5.5V. The device delivers up to 10A of load current with excellent load-and-line regulation. The MAX5951 PWM section utilizes a voltage-mode control s ...
Current transformers: how to specify them
Current transformers: how to specify them

... intended to monitor one or more parameters of the installation, for example: currents, voltage, temperature, frequency, etc. These values are permanently measured and compared with setpoints or thresholds beyond which the situation is defined as abnormal and dangerous. When a fault occurs, the prote ...
1SS361UDJ Features Mechanical Data
1SS361UDJ Features Mechanical Data

... written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instruct ...
MAX8844Z/MAX8844Y 28V Dual Input Linear Li+ Battery Chargers with General Description
MAX8844Z/MAX8844Y 28V Dual Input Linear Li+ Battery Chargers with General Description

... The MAX8844Z/MAX8844Y chargers use voltage, current, and thermal-control loops to charge a single Li+ cell and protect the battery (Figure 1). When a Li+ battery with a cell voltage below 2.5V is inserted, the MAX8844Z/MAX8844Y chargers enter a prequalification stage where they precharge that cell w ...
IRFIB6N60A,SiHFIB6N60A
IRFIB6N60A,SiHFIB6N60A

... statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and / or ...
MAX17502 60V, 1A, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description
MAX17502 60V, 1A, Ultra-Small, High-Efficiency, Synchronous Step-Down DC-DC Converter General Description

... value. RESET goes high 1024 clock cycles after FB rises above 95.5% of its set value. RESET is valid when the device is enabled and VIN is above 4.5V. ...
Electronics and Electrical instruments
Electronics and Electrical instruments

Tutorial - Virtual Physiology
Tutorial - Virtual Physiology

Current transformers: how to specify them
Current transformers: how to specify them

... intended to monitor one or more parameters of the installation, for example: currents, voltage, temperature, frequency, etc. These values are permanently measured and compared with setpoints or thresholds beyond which the situation is defined as abnormal and dangerous. When a fault occurs, the prote ...
< 1 ... 233 234 235 236 237 238 239 240 241 ... 1601 >

Ohm's law

  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report