• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Unit 7. Digital-to-Analog Conversion
Unit 7. Digital-to-Analog Conversion

DC – DC CONVERTER 1000W 100 - 400VDC Input / 12VDC Output
DC – DC CONVERTER 1000W 100 - 400VDC Input / 12VDC Output

... converter by switching OFF and ON the ENABLE signal). If an output short-circuit happens, the converter turns itself off for 1 min and than it tries to restart again until the ENABLE signal is ON. During the 1 min off-time is it possible to reset the converter by taking off the high voltage input. * ...
ATA1226_light loads power_FINAL
ATA1226_light loads power_FINAL

Project 2: Regulated Power Supply
Project 2: Regulated Power Supply

... The LTspice circuit diagram for this project is presented in figure 5-4 on the right. It is a voltage follower circuit whose output current is amplified by the transistor, Q1. A Linear Technology LT1004-1.2 is used for the voltage reference in the simulation. This is a precision voltage reference th ...
E3YF400VFAL02 Technical data
E3YF400VFAL02 Technical data

... on-position after the set interval of the tripping delay (ON-Delay) has expired and if the measured voltage is within the fixed adjusted window. When the measured voltage leaves the window between the fixed adjusted range, the output relay R switches into off-position If the voltage reenter the adju ...
CD54HC21/3A CD54HCT21/3A Dual 4-Input AND Gate Functional Diagram
CD54HC21/3A CD54HCT21/3A Dual 4-Input AND Gate Functional Diagram

... TA = -55oC to +100oC (Package F) . . . . . . . . . . . . . . . . . . 500mW TA = +100oC to +125oC (Package F) . . . . . . . . Derate Linearly at 8mW/ oC to 300mW Operating Temperature Range, TA Package Type F . . . . . . . . . . . . . . . . . . . . . . . . . . -55oC to +125oC Storage Temperature, TST ...
Evaluates:  MAX1744/MAX1745 MAX1744 Evaluation Kit General Description Features
Evaluates: MAX1744/MAX1745 MAX1744 Evaluation Kit General Description Features

... output), and select the external voltage-divider resistors, R2 and R3. The MAX1745 allows the output voltage to be set from 1.25V to 18V. The only other modification required is to remove the shunt from JU2. For output voltages greater than 5V, replace output capacitor C3 with a higher voltage ratin ...
Hi Friends 1. Of the following bridges the one which can be used for
Hi Friends 1. Of the following bridges the one which can be used for

ECG-Amplifier
ECG-Amplifier

Transtector Power Conditioning with Voltage Regulation
Transtector Power Conditioning with Voltage Regulation

2A Sink/Source Bus Termination EUP7171 DESCRIPTION
2A Sink/Source Bus Termination EUP7171 DESCRIPTION

... control circuitry. The limitation on input voltage selection is that VIN must be equal to or lower than VCNTL. For DDR I application, a separation connection of VIN and VCNTL to 2.5V and 3.3V respectively can achieve better output drive capability. ...
Analog to Floating Point Output
Analog to Floating Point Output

Ohms - HCC Learning Web
Ohms - HCC Learning Web

Q.1 What is the lowest positive integer whose Least significant digit
Q.1 What is the lowest positive integer whose Least significant digit

... Q.6 Combinational ckt to output 2’s complement of continuous input stream. Q.7 To find maximum clock periods of four circuit of two cascaded D-f/fs having different directions of clock and different position of buffers for delay. Also to find out which circuit won’t work reliably as shift register. ...
2033D Facility Planning Data Sheet
2033D Facility Planning Data Sheet

... CFM ...
V in - WSU EECS - Washington State University
V in - WSU EECS - Washington State University

ICM408 3-Phase Line Monitor
ICM408 3-Phase Line Monitor

SOLATRON™ Plus Three Phase Power Conditioners Catalog Pages
SOLATRON™ Plus Three Phase Power Conditioners Catalog Pages

... Contact Technical Services at (800) 377-4384 with any questions. Visit our website at www.solahd.com. ...
p130_holman_poster
p130_holman_poster

CIRCUIT FUNCTION AND BENEFITS
CIRCUIT FUNCTION AND BENEFITS

... input voltage. For the AD7625, the common-mode voltage is one-half the internal reference voltage, REF/2, where REF = 4.096 V. ...
LAB 8 RC Circuits τ
LAB 8 RC Circuits τ

... Part 1: Using a Stop Watch to Measure the Time Constant a. Construct an RC circuit consisting of a 1000 µF low-leakage capacitor in series with a 22 kΩ resistor, and a power supply set to 10V. Make sure that the capacitor is attached to the ground and use a DMM to measure this voltage VC. b. Predict ...
Series 1654 - Wilmore Electronics
Series 1654 - Wilmore Electronics

Testing, Measurement, and Troubleshooting
Testing, Measurement, and Troubleshooting

Testing, Measurement, and Troubleshooting
Testing, Measurement, and Troubleshooting

AD8210 AD8274 AD780
AD8210 AD8274 AD780

... the "Circuits from the Lab". Information furnished by Analog Devices is believed to be accurate and reliable. However, "Circuits from the Lab" are supplied "as is" and without warranties of any kind, express, implied, or statutory including, but not limited to, any implied warranty of merchantabilit ...
< 1 ... 606 607 608 609 610 611 612 613 614 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report