• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Serial Communication
Serial Communication

... We could use a light source and transparent/opaque segments ...
CS5490 Two Channel Energy Measurement IC
CS5490 Two Channel Energy Measurement IC

... functions, such as energy pulse generation, voltage sag and swell, overcurrent and zero-crossing detection, and line frequency measurement. A separate analog-to-digital converter is used for on-chip temperature measurement. The CS5490 is optimized to interface to current transformers, shunt resistor ...
BD00IC0MEFJ-LB
BD00IC0MEFJ-LB

General Description Benefits and Features
General Description Benefits and Features

... The The MAX4230–MAX4234 single/dual/quad, highoutputdrive CMOS op amps feature 200mA of peak output current, rail-to-rail input, and output capability from a single 2.7V to 5.5V supply. These amplifiers exhibit a high slew rate of 10V/μs and a gain-bandwidth product (GBWP) of 10MHz. The MAX4230–MAX4 ...
Sepam Series 20
Sepam Series 20

... avoided, can result in minor or moderate injury. ...
WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER
WT300 Series THE 5TH GENERATION OF THE WORLD'S BEST SELLING POWER METER

... Conventionally, when power meters operate in an integration mode to measure power consumption and standby power, the measuring ranges need to be fixed. However, if the level of the input exceeds the maximum of the selected range, the results will be incorrect and the test will need to be repeated wi ...
wt300 series digital power meter
wt300 series digital power meter

TMS320C5515/05/VC05 DSP Successive Approx. Register (SAR
TMS320C5515/05/VC05 DSP Successive Approx. Register (SAR

63-1328—06 - Spyder® BACnet® Programmable
63-1328—06 - Spyder® BACnet® Programmable

... Each controller uses a BACnet MS/TP communications port. The controller’s data is presented to other controllers over a twisted-pair MS/TP network, which uses the EIA485 signaling standard capable of the following baud rates: 9.6, 19.2, 38.4, 76.8, or 115.2 kilobits per second (configured at global ...
Application Note DrBlade™ 2 Selection of Boot Capacitor Value
Application Note DrBlade™ 2 Selection of Boot Capacitor Value

... that the boot capacitor is properly recharged during each cycle. Other modes of operation – for example, discontinuous conduction mode (DCM), or a disengaged phase in dynamic phase-shedding operation in multiphase buck converters – can lead to extended periods of tri-state operation during which bot ...
AD7294 12-Bit Monitor and Control System with Multichannel
AD7294 12-Bit Monitor and Control System with Multichannel

... into a SAR analog-to-digital converter (ADC) with a 3 μs conversion time. A high accuracy internal reference is provided to drive both the digital-to-analog converter (DAC) and ADC. Four 12-bit DACs provide the outputs for voltage control. The AD7294 also includes limit registers for alarm functions ...
ICS674-01 - Integrated Device Technology
ICS674-01 - Integrated Device Technology

... termination resistor of 33Ω should be used in series with OUTA and OUTB pins. ...
HMC550 数据资料DataSheet下载
HMC550 数据资料DataSheet下载

... 1,000 pF Capacitor, 0402 Pkg. ...
Dual Precision Retriggerable/Resettable Monostable
Dual Precision Retriggerable/Resettable Monostable

GTL2002 1. General description 2-bit bidirectional low voltage translator
GTL2002 1. General description 2-bit bidirectional low voltage translator

... high-speed voltage translation with low ON-state resistance and minimal propagation delay. The GTL2002 provides 2 NMOS pass transistors (Sn and Dn) with a common gate (GREF) and a reference transistor (SREF and DREF). The device allows bidirectional voltage translations between 1.0 V and 5.0 V witho ...


... Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo ...
Three Intuitive, Easy-to-use Indicators Safety Light Curtain
Three Intuitive, Easy-to-use Indicators Safety Light Curtain

... Test input, reset input, external device monitoring input, and function selection input are all ON voltage: 11 to 24 V OFF voltage: 0 to 5 V, or open Operating range selection input ON voltage: 11 to 24 V OFF voltage: 0 to 5 V ...
Joslyn Hi-Voltage® Capacitor Switches
Joslyn Hi-Voltage® Capacitor Switches

... t Solenoid or motor operating mechanism with AC or DC control voltage Joslyn Hi-Voltage® Varmaster switching systems use VBM switches that are completely sealed, breaker-class devices using a vacuum as the interrupting dielectric. VBM switches offer high reliability with little or no maintenance and ...
Si photodiodes - Hamamatsu Photonics
Si photodiodes - Hamamatsu Photonics

Zener voltage
Zener voltage

Lecture 5b: Common-mode feedback
Lecture 5b: Common-mode feedback

Open drain microprocessor reset
Open drain microprocessor reset

... input current and leakage paths connected to the reset output line. A 10k pull-up is sufficient in most applications. The STM6315 asserts a reset signal to the MCU whenever VCC goes below the reset threshold (VRST), or when the manual reset input (MR) is taken low (see Figure 5 and Figure 6 on page ...
16-Bit, 500 kSPS PulSAR ADC in MSOP/QFN AD7686
16-Bit, 500 kSPS PulSAR ADC in MSOP/QFN AD7686

... ADA4941 ADA4841 ADA4941 ADA4841 ...
PAM8615 Description Pin Assignments
PAM8615 Description Pin Assignments

... The PAM8615 is a high-performance CMOS audio amplifier that requires adequate power supply decoupling to ensure the output total harmonic distortion (THD) as low as possible. Power supply decoupling also prevents oscillations caused by long lead between the amplifier and the speaker. The optimum dec ...
Automotive Stepper Driver A4992
Automotive Stepper Driver A4992

< 1 ... 40 41 42 43 44 45 46 47 48 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report