• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LAMPIRAN B DATASHEET Wirewound 3590 ................................................................................................................   B – 2
LAMPIRAN B DATASHEET Wirewound 3590 ................................................................................................................ B – 2

... With single supply operation, careful attention should be paid to input common-mode range, output voltage swing of both op amps, and the voltage applied to the IAREF terminal. VIN+ and VIN– must both be 1V above ground for linear operation. You cannot, for instance, connect the inverting input to gr ...
Appendix S1 Circuit with Improved Hill Function We present a
Appendix S1 Circuit with Improved Hill Function We present a

... 0.49 V across Rb1 which is small enough so that the transistor current is essentially zero. In the circuit, the maximal protein expression corresponds to Vi-1 = 0 which results in U2 output going negative with a limit at the lower saturation level V-sat = -3.5 V for the dual op-amp LF412 supplied by ...
DN451 - Current Sense Amp Inputs Work from –0.3V to 44V Independent of Supply
DN451 - Current Sense Amp Inputs Work from –0.3V to 44V Independent of Supply

... with the monitored conductor and determining the voltage across the sense resistor. To minimize power loss in the sense resistor it is kept as small as possible, resulting in a small differential voltage that must be monitored on top of what may be a fairly large varying common mode voltage. The LT® ...
m4.4 Signal Processing Circuits: (a) Design a two
m4.4 Signal Processing Circuits: (a) Design a two

Digital to Analog Converters (DAC)
Digital to Analog Converters (DAC)

Problem Set 5 SOLUTIONS
Problem Set 5 SOLUTIONS

Aalborg Universitet Thøgersen, Paul Bach
Aalborg Universitet Thøgersen, Paul Bach

Capacitor Transient Analysis
Capacitor Transient Analysis

...  100mA R 1000 ...
O A RIGINAL RTICLES
O A RIGINAL RTICLES

... regulation. Industrial power supplies are used for applications such as: aircraft power supplies, paper mill, laser power supplies, radar/sonar power supplies, battery charger, and marine propulsion systems (Basile, et al.,2000; Beiranvand et al., 2010; Badin and Barbi2010). In today's industry, it ...
High Efficient Bidirectional Battery Converter for Residential PV Systems Cam Pham Tamas Kerekes
High Efficient Bidirectional Battery Converter for Residential PV Systems Cam Pham Tamas Kerekes

AD8564 数据手册DataSheet 下载
AD8564 数据手册DataSheet 下载

... near the switching threshold. Figure 17 shows a method for configuring the AD8564 with hysteresis. COMPARATOR ...
OP97
OP97

... precision op amp, the OP07. The OP97 can be substituted directly into OP07, OP77, AD725, and PM1012 sockets with improved performance and/or less power dissipation and can be inserted into sockets conforming to the 741 pinout if nulling circuitry is not used. Generally, nulling circuitry used with e ...
LT1077 - Micropower, Single Supply, Precision Op Amp
LT1077 - Micropower, Single Supply, Precision Op Amp

... This results in low frequency (0.1Hz to 10Hz) noise performance which can only be found on devices with an order of magnitude higher supply current. The LT1077 is completely plug-in compatible (including nulling) with all industry standard precision op amps. Thus, it can replace these precision op a ...
LEP 4.1.03 Internal resistance and matching in voltage source
LEP 4.1.03 Internal resistance and matching in voltage source

Evaluates:  MAX1733/MAX1734 MAX1734 Evaluation Kit General Description Features
Evaluates: MAX1733/MAX1734 MAX1734 Evaluation Kit General Description Features

... Evaluating Other Output Voltages The output is set to +1.8V by shorting the feedback pin (FB/OUT) to VOUT. This is the default setting for the MAX1734 EV kit. To generate output voltages other than +1.8V (+1.25V to +2.0V), the MAX1734EUK18 must be replaced with a different output MAX1734 or the MAX1 ...
Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power
Delphi Series E48SH, 120W Eighth Brick Family DC/DC Power

... output at the point of load, please connect SENSE(+) to Vo(+) and SENSE(–) to Vo(–) at the module. The output voltage can be increased by both the remote sense and the trim; however, the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sen ...
Monobloc Power Amplifier Stealth Max Users' Manual
Monobloc Power Amplifier Stealth Max Users' Manual

... The bias adjustment potentiometer is located on the rear apron next to the green bias measurement jacks. When installing a new pair of output tubes, start with the potentiometer at the position it was for the previous tubes. A multimeter capable of reading at least 2 VDC is required, Connect the red ...
Experiment 4 - UniMAP Portal
Experiment 4 - UniMAP Portal

Series Circuits
Series Circuits

... that has extensive applications in the analysis of electronic circuits. For the above notational standards, the following relationship exists: ...
GZ3412811286
GZ3412811286

... To calculate the power losses in the various components of the converter, the currents in the components of the converter circuits were measured and the values of the parasitic components (see Table I) were estimated. The measured currents, voltages, and the estimated component values were used to c ...
click here
click here

... will not draw enough current to worry about connecting it directly to battery power. The accessory output should be connected to the REMOTE inputs of all amplifiers. Therefore, very little current will be drawn from the head unit’s remote line, thus protecting the head unit in cases where multiple a ...
FAN2512, FAN2513 150 mA CMOS LDO Regulators with Fast Start Enable Features
FAN2512, FAN2513 150 mA CMOS LDO Regulators with Fast Start Enable Features

... General PWB Layout Considerations To achieve the full performance of the device, careful circuit layout and grounding technique must be observed. Establishing a small local ground, to which the GND pin, the output and bypass capacitors are connected, is recommended, while the input capacitor should ...
voltage_regulator2
voltage_regulator2

... Transformers convert AC electricity from one voltage to another with little loss of power through inductively coupled electrical conductors. Transformers work only with AC voltage Step-up transformers increase voltage. Step-down transformers reduce voltage. ...
EE2003 Circuit Theory
EE2003 Circuit Theory

... • A loop(迴路) is any closed path in a circuit. • A network with b branches, n nodes, and l independent loops will satisfy the fundamental ...
C43030914
C43030914

... Solar PV systems are widely preferred and also area of research in recent times. Maximum performance is obtained from PV panel by using MPPT algorithms. Comparative surveys and evaluations are presented in [1] – [3]. Among the many MPPT algorithms the Perturbation and Observation (P&O) is the simple ...
< 1 ... 423 424 425 426 427 428 429 430 431 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report