• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Capacitor Self
Capacitor Self

... 10) Assemble a non-inverting amplifier circuit as was done in the previous section. 11) From the power splitter on your project board, connect +vcc to +10 volts and -vcc to -10 volts. Note: since we are amplifying a DC voltage, we will not need more than a -2 to +10 volt power supply, however for si ...
Designing Non-Invert Buck-Boost (Zeta) Cnvrts
Designing Non-Invert Buck-Boost (Zeta) Cnvrts

... Figure 1. COT regulators do not require loop compensation and provide excellent transient performance with minimum design effort. Nonsynchronous operation results in reduced switching frequency at a very light load which delivers higher efficiency than a comparable fixed frequency converter. In many ...
Alternating Voltage and Current
Alternating Voltage and Current

... magnetic field to generate induced ac voltage across open terminals.  At the horizontal position, the loop does not induce a voltage because the conductors do not cut across the flux.  At the vertical position, conductors cut across the flux and produce maximum v.  Each of the longer conductors h ...
PIN and APD Photodiode characteristics
PIN and APD Photodiode characteristics

... source is provided for this purpose. The LED source is mains powered. The LED DC current can be set by a potentiometer on the front panel of the unit. A pair of terminals is also provided in the front panel of the LED source to measure the LED current. For this exercise these terminals can be shorte ...
Bates
Bates

Kang_vector_control_algorithm
Kang_vector_control_algorithm

MM74HCT273 Octal D-Type Flip-Flop with Clear MM74HCT273 Oct a
MM74HCT273 Octal D-Type Flip-Flop with Clear MM74HCT273 Oct a

... ■ Fanout of 10 LS-TTL loads ...
Example 2.7 for the circuit shown apply KVL to each designated
Example 2.7 for the circuit shown apply KVL to each designated

... • Math explanation: Node voltage analysis leads to ...
RT8300 - Richtek
RT8300 - Richtek

... the 4-CH and ICs respectively. The constant current output is adjustable from 5mA to 150mA via an external resistor (RISET). The LED brightness can also be adjusted via the PWMI pin with pulse width modulation from 0% to 100%. Thus allowing for wide VF variation. Moreover, the RT8300 provides Dynami ...
MAX9030/MAX9031/ MAX9032/MAX9034 Low-Cost, Ultra-Small, Single/Dual/Quad Single-Supply Comparators
MAX9030/MAX9031/ MAX9032/MAX9034 Low-Cost, Ultra-Small, Single/Dual/Quad Single-Supply Comparators

... rises above the trip point. VTL is the threshold voltage at which the comparator switches its output from low to high as VIN drops below the trip point. 2) The hysteresis band will be: VHYS = VTH - VTL = VDD(R2 / (R1 + R2)) 3) In this example, let VDD = +5V and VREF = +2.5V. VTH = 2.5V + 2.5(R2 / (R ...
MAX8556/MAX8557 4A Ultra-Low-Input-Voltage LDO Regulators General Description
MAX8556/MAX8557 4A Ultra-Low-Input-Voltage LDO Regulators General Description

... The MAX8556/MAX8557 low-dropout linear regulators operate from input voltages as low as 1.425V and are able to deliver up to 4A of continuous output current with a typical dropout voltage of only 100mV. The output voltage is adjustable from 0.5V to VIN - 0.2V. Designed with an internal p-channel MOS ...
Fixed capacitor bank 12kV spec
Fixed capacitor bank 12kV spec

... 4.1 Acceptable overcurrent and overvoltage CP 214 capacitor banks are designed for: - 1,10 x Un overvoltage - 12 hours per day, - 1,15 x Un power frequency overvoltage - 30 minutes per day, - Permanent overcurrent : 1,3 x In. 4.2 Design voltage, design power and marking According to IEC 60871 recomm ...
Opman SC5X v09.qxd - Fieldpiece Instruments
Opman SC5X v09.qxd - Fieldpiece Instruments

... For accuracies of ±1°, calibrate to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used. 1. Select 400°F/C range and connect thermocouple. 2. Remove back case (2 screws on back, one near clamp, other ne ...
SR103 Datasheet
SR103 Datasheet

... Dual-Channel Safety Monitoring Relay • Power requirements—the SR103AM will accept 24 VAC/DC or 115 VAC • Inputs—the SR103AM will accept single or dual N/C inputs or dual inputs from a light curtain (see SR102AM for application wiring for a light curtain) • Outputs—the SR103AM has 3 N/O outputs to ...
F. Radiometers
F. Radiometers

... subtracted. By far the biggest time-dependent signal (spanning a range of about 1 K) is caused by ground radiation entering the prime-focus feed via leakage through the reflector mesh and spillover. Fortunately, this unwanted ground signal varies smoothly with telescope elevation, so subtracting a s ...
3-channel mixer power amplifier A-901A
3-channel mixer power amplifier A-901A

... The TOA A-901A Mixer Power Amplifier controls and mixes up to three independent input signals. The A-901A delivers up to 10 watts of output power. Thirty five optional accessory modules are available to allow the A-901A amplifier to be configured for a variety of applications. Edge connectors on the ...
Transient DC Circuits - The University of Texas at Dallas
Transient DC Circuits - The University of Texas at Dallas

... circuit is often referred to as • As τ grows smaller, transient “th RL ti “the time constant.” t t” behavior disappears much faster, as in the RC case. ...
Using Op Amps as Comparators INTRODUCTION by James Bryant
Using Op Amps as Comparators INTRODUCTION by James Bryant

... time a signal takes from input to output) and often depends on the amount of overdrive. Because few op amps are characterized for their recovery times from differing levels of overdrive, it is necessary for the user to determine, by experiment, the delays likely to result from the levels of overdriv ...
SmartOnline 100kVA Modular 3-Phase UPS System, On
SmartOnline 100kVA Modular 3-Phase UPS System, On

... Scalable, modular N+1 configurations support hot-swap replacement of any of the six self-contained 20kVA power modules while connected equipment remains powered One open slot accommodates up to one additional 20kVA power module for increased capacity up to 120kVA Parallel applications enable the con ...
SNA-386 DC-3  GHz,  Cascadable GaAs  MMIC  Amplifier Product Description
SNA-386 DC-3 GHz, Cascadable GaAs MMIC Amplifier Product Description

... this information, and all such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. Sirenza Microdevices does not authorize ...
A Review on Performance Analysis of Matrix Converter
A Review on Performance Analysis of Matrix Converter

... Promising Characteristics of MC [7-13] makes it very popular among researchers and industrialist. The positive characteristics of MC are: 1) High power density 2) Bidirectional power flow 3) Sinusoidal input and output waveforms 4) Reduced volume and weight 5) Operation with unity power factor 6) Lo ...
quadrature clock converter
quadrature clock converter

... Input for external component connection. A resistor connected between this input and VSS adjusts the output clock pulse width (Tow). For proper operation, the output clock pulse width must be less than or equal to the A,B pulse separation (TOW≤TPS). ...
Lab 2: Circuit Simulation - Electrical and Computer Engineering
Lab 2: Circuit Simulation - Electrical and Computer Engineering

LM3916 Dot/Bar Display Driver
LM3916 Dot/Bar Display Driver

... require more accurate detection. In the precision half-wave rectifier of Figure 4 the effective diode offset is reduced by a factor equal to the open-loop gain of the op amp. Filter capacitor C2 charges through R3 and discharges through R2 and R3, so that appropriate selection of these values result ...
1-Bit, 10MHz, 2nd-Order, Isolated Delta
1-Bit, 10MHz, 2nd-Order, Isolated Delta

< 1 ... 338 339 340 341 342 343 344 345 346 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report