Download SR103 Datasheet

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Integrating ADC wikipedia , lookup

Amplifier wikipedia , lookup

Wien bridge oscillator wikipedia , lookup

Regenerative circuit wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Audio power wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

CMOS wikipedia , lookup

Surge protector wikipedia , lookup

Current mirror wikipedia , lookup

Radio transmitter design wikipedia , lookup

Operational amplifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Valve RF amplifier wikipedia , lookup

Transistor–transistor logic wikipedia , lookup

Power electronics wikipedia , lookup

Valve audio amplifier technical specification wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Rectiverter wikipedia , lookup

Transcript
Safety Monitoring Relays
SR103AM
SR103AM
Dual-Channel Safety Monitoring Relay
• Power requirements—the SR103AM will accept 24 VAC/DC or 115 VAC
• Inputs—the SR103AM will accept single or dual N/C inputs or dual inputs from
a light curtain (see SR102AM for application wiring for a light curtain)
• Outputs—the SR103AM has 3 N/O outputs to route power to the coils of power
contactors, plus 1 N/C auxiliary output for signaling purposes
• External Device Monitoring (EDM) is provided with a N/C loop between S11/S12
and S21 on the SR103AM
• Monitored manual or automatic/manual reset modes are available on the
SR103AM. Monitored manual reset requires closure of the reset circuit followed
by opening of the circuit. Reset occurs when circuit is opened. Auto reset
requires only closure of the reset circuit as reset occurs when circuit is closed.
r
C
Specifications
I
Electrical
Power Supply:
Power Consumption:
Safety Inputs:
Max Input Resistance:
Outputs:
Output Rating AC:
Output Rating DC:
Min Switched Current/Voltage:
Impulse Withstand Voltage:
Max Drop-Out Time:
Max Output Fuse:
Reset Mode:
Contactor Monitoring:
Mechanical
Mounting:
Case Material:
Max Wire Size:
Weight:
Color:
External Switches:
Indication:
Mechanical Life:
Environmental
Enclosure Protection:
Operating Temperature:
All Models
SR103AM01
SR103AM02
±10%, 50-60 Hz
24 VAC/DC
115 VAC
Approx. 1 VA
1 N/C or 2 N/C or 2 solid state (light curtain)
800 Ohms per channel
3 N/O + 1 N/C auxiliary
Inductive AC-15, 3 A/230 VAC
Inductive DC-13, 2 A/24 V
10 mA/10 V
2500 V
12 ms (75 ms by removing supply voltage)
6 A quick-acting or 4 A slow-acting
Monitored manual (S11-S21) or automatic/manual (S12-S21)
N/C loop S11/S12-S21
35 mm (1.38 in.) DIN rail
Fiber-filled Polyamide PA6.6
1 x 2.5 mm 2 (14 AWG) stranded
230 g (8.1 oz.)
Red
None
Green = K1 Closed, Green = K2 Closed
1 x 10 7 operations
IP20 terminals, IP40 (NEMA 1) housing
24 VAC/DC: -15 to 40°C (5 to 104°F)
115 VAC: -15 to 40°C (5 to 104°F)
93% RH at 104°C (219°F)
Humidity:
Compliance
Standards:
EN 60204-1, EN 954-1, VDE 0113-1
Approvals/Listings:
CE marked for all applicable directives, UL and C-UL, TÜV Rheinland
Safety Category:
Cat. 4 per EN954-1 (SR103 internal operation)
Specifications are subject to change without notice.
Note:
The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e., with the guard closed,
actuator in place, and the machine able to be started.
I50
US
Conforms to EN60204-1, EN954-1,
VDE 0113-1
UL and C-UL listed
TÜV Rheinland approved
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com
SR103AM
Safety Monitoring Relays
Application
24VAC/DC, 110VAC
K1 (AUX)
START
MOMENTARY
PUSH
BUTTON
EB SERIES
LATCHING
E-STOP
BUTTON
GUARD
CLOSED
A1
11
12
21
22
S11
S14
13
RESET
23
33
MOMENTARY
PUSH
BUTTON
41
K1
Relay control and
fault monitoring
Power supply
(S11 = 24 V)
33
STOP
MOMENTARY
PUSH
BUTTON
S12
S21
L1 L2 L3
K2 (AUX)
+
K2
K2
34
CONTACT
PROTECTION
E.G. THERMAL
CUT OUT
+
K1
T5009
INTERLOCK
SWITCH
SR103AM
A2
S10
S13
14
24
34
M
42
FUSE
FUSE
K1
K2
I
a full explanation of the circuit operating principle and fault detection,
✎ For
see “Common Circuit Examples” in The Safety Library Section of this catalog on page A62
Output Contact Arrangements
Terminal Pin Assignments
14
S12
A1
13
24
S13
S11
23
34
S10
S14
33
42
A2
S21
41
SR103AM
Terminal Connections
13
A1
SUPPLY
23
S13
SAFETY
OUTPUT 1
N/O
A2
INPUT #1
N/C
SAFETY
OUTPUT 2
N/O
S10
14
33
S11
INPUT #2
N/C
SAFETY
OUTPUT 3
N/O
S12
24
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
41
S21
EDM AND
RESET
AUXILIARY
SIGNALING
N/C
S12
34
For the Latest Information
On the Internet: www.sti.com
42
I51
SR103AM
Safety Monitoring Relays
Block Diagram
A1
S11
S21
A2
A2
L1
S10
33
41
14
24
34
42
K1
+
DC +U B 0V
AC
23
+
Pin assignment
A1
13
Relay control and
fault monitoring
Power supply
(S11=24V)
UB
S14
S12
K2
N
S13
Dimensions
(mm/in.)
SR103AM
114
4.5
22.5
0.885
I
99
3.9
35
DIN RAIL MOUNTING
1.38
Ordering
Model
Supply
Inputs
Outputs
Auxiliary
Part No.
SR103AM01
24 VAC/DC
2 N/C
3 N/O
1 N/C
44510-1031
SR103AM02
115 VAC
2 N/C
3 N/O
1 N/C
44510-1032
I52
= Highlighted Rapid Delivery products are available for shipment today or within FIVE days.
Omron Scientific Technologies, Inc.
USA Tel. 1/888/510-4357 Canada Tel. 1/866/986-6766
For the Latest Information
On the Internet: www.sti.com