• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
RPM971-H14
RPM971-H14

... product described in this document are for reference only. Upon actual use, therefore, please request that specifications to be separately delivered. Application circuit diagrams and circuit constants contained herein are shown as examples of standard use and operation. Please pay careful attention ...
Photologic® Slotted Optical Switch
Photologic® Slotted Optical Switch

MAX9210/MAX9214/MAX9220/MAX9222 Programmable DC-Balance 21-Bit Deserializers General Description
MAX9210/MAX9214/MAX9220/MAX9222 Programmable DC-Balance 21-Bit Deserializers General Description

... 2.4V, allowing approximately ±1V common-mode difference between the driver and receiver on a DC-coupled link (2.4V - 1.425V = 0.975V and 1.075V - 0V = 1.075V). Common-mode voltage differences may be due to ground potential variation or common-mode noise. If there is more than ±1V of difference, the ...
Chapter17
Chapter17

Application Note AN4146 Design Guidelines for Quasi-Resonant Converters )
Application Note AN4146 Design Guidelines for Quasi-Resonant Converters )

... normal operation (∆B) as well as the maximum flux density in transient (Bmax). The the maximum flux density swing in normal operation is related to the hysteresis loss in the core while the maximum flux density in transient is related to the core saturation. With the chosen core, the minimum number ...
Chapter 1 Introduction to Electronics
Chapter 1 Introduction to Electronics

... • An electronic circuit generally contains both the passive and active components. Therefore a dc power supply is essential for the operation of its active components. An electronic processing or amplifier devices also need different power source than its DC operating power source called input signa ...
TPS60500 数据资料 dataSheet 下载
TPS60500 数据资料 dataSheet 下载

... voltage of 1.8 V to 6.5 V. The devices use switched capacitor fractional conversion to achieve high efficiency over the entire input and output voltage range. Regulation is achieved by sensing the output voltage and enabling the internal switches as needed to maintain the selected output voltage. Th ...
Electronic Voltmeters and Ammeters
Electronic Voltmeters and Ammeters

... Alessandro Ferrero was born in Milano (Milan), Italy, in 1954. He received his M.S. degree in Electrical Engineering from the Politecnico di Milano in 1978. In 1983 he joined the Dipartimento di Elettrotecnica of the Politecnico di Milano as an Assistant Professor on Electrical Measurements. From 19 ...
Chapter 10: Operational Amplifiers
Chapter 10: Operational Amplifiers

Model 2026 Spectroscopy Amplifier Data Sheet
Model 2026 Spectroscopy Amplifier Data Sheet

... Gain (SFG) control. The SFG provides gain resolution better than 1 in 16 000 (0.00625%), allowing greater precision for more accurate peak location in less time. This feature is now a requirement, instead of a luxury, for most spectroscopy systems. This is especially true in applications using detec ...
MAX1280/MAX1281 400ksps/300ksps, Single-Supply, Low-Power, 8-Channel, Serial 12-Bit ADCs with Internal Reference General Description
MAX1280/MAX1281 400ksps/300ksps, Single-Supply, Low-Power, 8-Channel, Serial 12-Bit ADCs with Internal Reference General Description

... Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain error and offset error have been nulled. Note 3: Offset nulled. Note 4: Ground “on” channel; sine wave applied to all “off” channels. Note 5: Conversion time is defined as the number ...
LMX2335/LMX2336/LMX2337 PLLatinum Dual Frequency Synthesizer for RF Personal Communications
LMX2335/LMX2336/LMX2337 PLLatinum Dual Frequency Synthesizer for RF Personal Communications

... Each N counter consists of the 7-bit swallow counter (A counter) and the 11-bit programmable counter (B counter). If the Control Bits are 10 or 11 (10 for RF2 counter and 11 for RF1 counter) data is transferred from the 20-bit shift register into a 7-bit latch (which sets the Swallow (A) Counter) an ...
LT1054 数据资料 dataSheet 下载
LT1054 数据资料 dataSheet 下载

... CAP+ is the positive side of input capacitor CIN and is driven alternately between VCC and ground. When driven to VCC, CAP+ sources current from VCC. When driven to ground, CAP+ sinks current to ground. CAP− is the negative side of the input capacitor and is driven alternately between ground and VOU ...
Basic Techniques for Accurate Resistance Measurement
Basic Techniques for Accurate Resistance Measurement

... recommend?” our Application Specialists help them narrow it down by asking, “What’s the resistance range you’re trying to measure? Milliohm, kilohm?” Before starting your particular application, it’s important to consider that each of these ranges require the use of different measurement techniques ...
Enhancement of Power Quality in Renewable Energy System by
Enhancement of Power Quality in Renewable Energy System by

... very hard under the light load. If the five-level output voltage is expected, extra two diodes and four power electronic switches are required. Fig. 1(b) shows the circuit configuration of a basic flying capacitor multilevel inverter. As can be seen, it is configured by three dc capacitors and four ...
basics of electronics lab manual i, ii semester
basics of electronics lab manual i, ii semester

Full-power converter based test bench for low voltage
Full-power converter based test bench for low voltage

... According to [2] there are generally four different types of voltage dip generators: 1) rotating generator based, 2) shunt (or switched) impedance based, 3) transformer based and 4) full-power converter based. An overview on each of them is shown in Fig. 1. Shunt impedance based solutions are most o ...
LT6600-10
LT6600-10

... Interfacing to the LT6600-10 Note: The referenced pin numbers correspond to the S8 package. See the Pin Functions section for the equivalent DFN-12 package pin numbers. The LT6600-10 requires 2 equal external resistors, RIN, to set the differential gain to 402Ω/RIN. The inputs to the filter are the v ...
FAN2315 TinyBuck™ 15 A Integrated Synchronous Buck Regulator FAN2315 — TinyBuck™
FAN2315 TinyBuck™ 15 A Integrated Synchronous Buck Regulator FAN2315 — TinyBuck™

... To reduce VOUT ripple and achieve a smoother ramp of the output voltage, tON is modulated during soft-start. tON starts at 50% of the steady-state on-time (PWM Mode) and ramps up to 100% gradually. During normal operation, the SS voltage is clamped to 400 mV above the FB voltage. The clamp voltage d ...
a Precision Instrumentation Amplifier AD624
a Precision Instrumentation Amplifier AD624

... Specifications shown in boldface are tested on all production unit at final electrical test. Results from those tests are used to calculate outgoing quality levels. All min and max specifications are guaranteed, although only those shown in boldface are tested on all production units. ...
MAX1516A/MAX1517A/MAX1518A TFT-LCD DC-DC Converters with Operational Amplifiers General Description
MAX1516A/MAX1517A/MAX1518A TFT-LCD DC-DC Converters with Operational Amplifiers General Description

... The MAX1516A/MAX1517A/MAX1518A include a highperformance step-up regulator, two linear-regulator controllers, and high-current operational amplifiers for active-matrix thin-film transistor (TFT) liquid-crystal displays (LCDs). Also included is a logic-controlled, highvoltage switch with adjustable d ...
THE DC OPERATING POINT
THE DC OPERATING POINT

Datasheet
Datasheet

... the specifications of RS-232 and V.28 serial protocols. The devices are pin-to-pin compatible with popular industry standard pinouts. The SP233A / SP310A / SP312A offer 120kbps data rate under load, small ceramic type 0.1μF charge pump capacitors and overall ruggedness for comercial applications. Fe ...
2350 POWER SERIES Selector Guide
2350 POWER SERIES Selector Guide

... Fixed 4 position selectable internally Out of range indication: Flashing display. Except model 2358. Conversion: Integration: 250 milliseconds nominal, sample rate: 2.5 times/sec. Conversion type: Dual slope integration with auto zero. Polarity: Automatic " + " or " - " sign displayed or no polarity ...
Zener diodes as voltage regulators
Zener diodes as voltage regulators

< 1 ... 268 269 270 271 272 273 274 275 276 ... 661 >

Integrating ADC



An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report