BD4157MUV
... These are the input terminals for each channel of a 3ch switch. V3_IN and V15_IN terminals have two pins each, which should be short-circuited on the pc board with a thick conductor. A large current runs through these three terminals : (V3_IN: 1.3A; V3AUX_IN: 0.275 A; and V15_IN: 0.65 A). In order t ...
... These are the input terminals for each channel of a 3ch switch. V3_IN and V15_IN terminals have two pins each, which should be short-circuited on the pc board with a thick conductor. A large current runs through these three terminals : (V3_IN: 1.3A; V3AUX_IN: 0.275 A; and V15_IN: 0.65 A). In order t ...
INVERTER HF-320 Series
... starting characteristic is different from those obtained from commercial power supply operation. Although the starting torque is smaller with an inverter than with the commercial power supply, a high starting torque can be produced at low speeds by adjusting the V/f pattern torque boost amount or by ...
... starting characteristic is different from those obtained from commercial power supply operation. Although the starting torque is smaller with an inverter than with the commercial power supply, a high starting torque can be produced at low speeds by adjusting the V/f pattern torque boost amount or by ...
P83862
... Typically used to trigger remote alerts or other reporting appliances. Form “C” contacts rated 28VDC at 1 AMP. Typically used to report AC or BAT Fail. An open circuit across this pair of terminals will cause IN1 and IN2 to simultaneously signal a trouble condition to the FACP. This output is capabl ...
... Typically used to trigger remote alerts or other reporting appliances. Form “C” contacts rated 28VDC at 1 AMP. Typically used to report AC or BAT Fail. An open circuit across this pair of terminals will cause IN1 and IN2 to simultaneously signal a trouble condition to the FACP. This output is capabl ...
MAX6715–MAX6729 Dual/Triple Ultra-Low-Voltage SOT23 µP Supervisory Circuits General Description
... system power-supply voltages. These devices assert a system reset if any monitored supply falls below its factorytrimmed or adjustable threshold and maintain reset for a minimum timeout period after all supplies rise above their thresholds. The integrated dual/triple supervisory circuits significant ...
... system power-supply voltages. These devices assert a system reset if any monitored supply falls below its factorytrimmed or adjustable threshold and maintain reset for a minimum timeout period after all supplies rise above their thresholds. The integrated dual/triple supervisory circuits significant ...
Components in Sensing Circuits Word Document
... If we were to connect the same bulb to a 12V battery, this resistance would only be sufficient to keep the current down to about 0.12A. This high current would probably burn out the filament, and the bulb would be destroyed. Extra resistance is required in the circuit to limit the current to 0.06A. ...
... If we were to connect the same bulb to a 12V battery, this resistance would only be sufficient to keep the current down to about 0.12A. This high current would probably burn out the filament, and the bulb would be destroyed. Extra resistance is required in the circuit to limit the current to 0.06A. ...
MC33814, Two cylinder small engine control IC - Data Sheet
... This pin provides the low-side drive for a tachometer gauge or alternatively as a SPI controlled low-side driver, or oscillator output. Output 5.0 V logic level ISO9141 data to the MCU from the ISO9141 IN/OUT pin ...
... This pin provides the low-side drive for a tachometer gauge or alternatively as a SPI controlled low-side driver, or oscillator output. Output 5.0 V logic level ISO9141 data to the MCU from the ISO9141 IN/OUT pin ...
HANDBOOK OF OPERATIONAL AMPLIFIER APPLICATIONS Application Report
... operational amplifier as a comparator – if the output stage is designed to be used that way as in a voltage limiting operational amplifier – or if clamping is added externally that prevents the output from saturating. These applications are shown. ...
... operational amplifier as a comparator – if the output stage is designed to be used that way as in a voltage limiting operational amplifier – or if clamping is added externally that prevents the output from saturating. These applications are shown. ...
Recloser Instruction Manual Multilin DGCR *1601-9207-B3*
... are trademarks or registered trademarks of GE Multilin Inc. The contents of this manual are the property of GE Multilin Inc. This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin Inc. This manual is for informational use only a ...
... are trademarks or registered trademarks of GE Multilin Inc. The contents of this manual are the property of GE Multilin Inc. This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin Inc. This manual is for informational use only a ...
FEATURES FUNCTIONAL BLOCK DIAGRAM
... Power Supply Connection for the GbE PLL. Ground Pins. The external paddle must be attached to GND. These pins are for bypassing each LDO to ground with a 220 nF capacitor. Power Supply Connection for the GbE VCO. Power Supply Connection for the 156M LVDS Output Buffer and Output Dividers. LVPECL/LVD ...
... Power Supply Connection for the GbE PLL. Ground Pins. The external paddle must be attached to GND. These pins are for bypassing each LDO to ground with a 220 nF capacitor. Power Supply Connection for the GbE VCO. Power Supply Connection for the 156M LVDS Output Buffer and Output Dividers. LVPECL/LVD ...
Design of Single-Switch Inverters for Variable Resistance
... switching for load variations of more than about a factor of two or three in resistance. In many applications – such as when the load resistance is well known, or the inverter is coupled to the load via an isolator – this load sensitivity is not problematic. In other applications, however, it would ...
... switching for load variations of more than about a factor of two or three in resistance. In many applications – such as when the load resistance is well known, or the inverter is coupled to the load via an isolator – this load sensitivity is not problematic. In other applications, however, it would ...
Using the Stellaris Microcontroller Analog-to
... Most analog-to-digital converter implementations in 8-,16-, and 32-bit microcontrollers require processor intervention to configure each conversion when the analog input/channel is changed. Luminary Micro's sequence-based architecture gives software the ability to enable up to four separate sample s ...
... Most analog-to-digital converter implementations in 8-,16-, and 32-bit microcontrollers require processor intervention to configure each conversion when the analog input/channel is changed. Luminary Micro's sequence-based architecture gives software the ability to enable up to four separate sample s ...
Radiation Noise Reduction Effect using Capacitor with
... Since the radiation noise from the electronic equipment is regulated in many countries, the effective techniques of radiated noise reduction is needed in the design and manufacturing fields of the equipment. It is well known that the radiated emission from the electronic equipment is often dominated ...
... Since the radiation noise from the electronic equipment is regulated in many countries, the effective techniques of radiated noise reduction is needed in the design and manufacturing fields of the equipment. It is well known that the radiated emission from the electronic equipment is often dominated ...
AVR1505
... the XMEGA A has a pipelined architecture. This means that a new analog voltage can be sampled each ADC clock cycle. Thus, a new ADC measurement can be started while other ADC measurements are ongoing. The result is that the conversion rate is much higher than the conversion time. ADC measurements ca ...
... the XMEGA A has a pipelined architecture. This means that a new analog voltage can be sampled each ADC clock cycle. Thus, a new ADC measurement can be started while other ADC measurements are ongoing. The result is that the conversion rate is much higher than the conversion time. ADC measurements ca ...
Comparison of the Josephson Voltage Standards of the NRC
... differences. Provision exists to remove data points from the statistical calculation and replace them with the next accepted data point if certain statistical limits are exceeded, but in practice this rarely happens if the step stability is adequate. During the direct comparison of the BIPM array w ...
... differences. Provision exists to remove data points from the statistical calculation and replace them with the next accepted data point if certain statistical limits are exceeded, but in practice this rarely happens if the step stability is adequate. During the direct comparison of the BIPM array w ...
UBA20261/2 600 V and 350 V power IC for step dimmable CFLs
... frequency fbridge(min) frequency. To avoid repeated ignition attempts and overheating of the application due to lamp damage, the IC only tries to ignite the lamp twice after power-up. The ignition attempt counter increments at the end of the ignition enabling time when the lamp ignition threshold vo ...
... frequency fbridge(min) frequency. To avoid repeated ignition attempts and overheating of the application due to lamp damage, the IC only tries to ignite the lamp twice after power-up. The ignition attempt counter increments at the end of the ignition enabling time when the lamp ignition threshold vo ...
TLC1514 数据资料 dataSheet 下载
... mode is slightly different, depending on how the converter performs the sampling and which host interface is used. The trigger for a conversion can be an active CSTART (extended sampling), CS (normal sampling, SPI interface), or FS (normal sampling, TMS320 DSP interface). When FS is used as the trig ...
... mode is slightly different, depending on how the converter performs the sampling and which host interface is used. The trigger for a conversion can be an active CSTART (extended sampling), CS (normal sampling, SPI interface), or FS (normal sampling, TMS320 DSP interface). When FS is used as the trig ...
Integrating ADC
An integrating ADC is a type of analog-to-digital converter that converts an unknown input voltage into a digital representation through the use of an integrator. In its most basic implementation, the unknown input voltage is applied to the input of the integrator and allowed to ramp for a fixed time period (the run-up period). Then a known reference voltage of opposite polarity is applied to the integrator and is allowed to ramp until the integrator output returns to zero (the run-down period). The input voltage is computed as a function of the reference voltage, the constant run-up time period, and the measured run-down time period. The run-down time measurement is usually made in units of the converter's clock, so longer integration times allow for higher resolutions. Likewise, the speed of the converter can be improved by sacrificing resolution.Converters of this type can achieve high resolution, but often do so at the expense of speed. For this reason, these converters are not found in audio or signal processing applications. Their use is typically limited to digital voltmeters and other instruments requiring highly accurate measurements.