NVT2001, NVT2002 - NXP Semiconductors
... transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or Bn port is LOW, the clamp is in the ON-state and a low resistance connection exists between the An and Bn ports. The low ON-state resistance (Ron) of the switch allows connections to ...
... transmission speeds < 33 MHz for an open-drain system with a 50 pF capacitance and a pull-up of 197 . When the An or Bn port is LOW, the clamp is in the ON-state and a low resistance connection exists between the An and Bn ports. The low ON-state resistance (Ron) of the switch allows connections to ...
ADG3247 数据手册DataSheet 下载
... sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Only one absolute maximum rating may be applied at any one time. ...
... sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Only one absolute maximum rating may be applied at any one time. ...
ScanTAP IsoPod User`s Manual
... (RMA) number on the shipping carton. Freight collect items will NOT be accepted. Customers or authorized sales representatives must first contact CORELIS with notice of request for return of merchandise. RMA's can only originate from CORELIS. If authorization is granted, an RMA number will be forwar ...
... (RMA) number on the shipping carton. Freight collect items will NOT be accepted. Customers or authorized sales representatives must first contact CORELIS with notice of request for return of merchandise. RMA's can only originate from CORELIS. If authorization is granted, an RMA number will be forwar ...
Characterisation and Generation of High Impulse Voltages and
... Test voltages actually appearing in a test circuit can contain oscillations at the peak as well as oscillations on the front. Reasons for such oscillations are the inductances and capacitances of the impulse voltage generator and those of the test and measuring circuits including the high voltage le ...
... Test voltages actually appearing in a test circuit can contain oscillations at the peak as well as oscillations on the front. Reasons for such oscillations are the inductances and capacitances of the impulse voltage generator and those of the test and measuring circuits including the high voltage le ...
1.02 ups system description
... Energy Saver: The UPS shall continuously monitor the voltage and frequency of the bypass source. When the source parameters are within acceptable limits, the UPS will utilize a minimal/optimal combination of its internal subsystems to ensure acceptable power is always delivered to the critical load, ...
... Energy Saver: The UPS shall continuously monitor the voltage and frequency of the bypass source. When the source parameters are within acceptable limits, the UPS will utilize a minimal/optimal combination of its internal subsystems to ensure acceptable power is always delivered to the critical load, ...
ELECTRONICS
... and consequently, ID and VGS. With voltage-divider bias, the dependency of ID on the range of Q-points is reduced (i.e. more stable) because the slope is less than for self-bias, although VGS varies quite a bit for both circuits. H. Chan; Mohawk College ...
... and consequently, ID and VGS. With voltage-divider bias, the dependency of ID on the range of Q-points is reduced (i.e. more stable) because the slope is less than for self-bias, although VGS varies quite a bit for both circuits. H. Chan; Mohawk College ...
RF5616 - Qorvo
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
... Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Abs ...
Navy Electricity and Electronics Training Series
... technicians in these ratings, this series provides beginners with fundamental electrical and electronic concepts through self-study. The presentation of this series is not oriented to any specific rating structure, but is divided into modules containing related information organized into traditional ...
... technicians in these ratings, this series provides beginners with fundamental electrical and electronic concepts through self-study. The presentation of this series is not oriented to any specific rating structure, but is divided into modules containing related information organized into traditional ...
User Manual - Sonel Analysis
... blue - current configuration is compatible with the analyzer, but differs from the one saved to the disk, yellow - the configuration is not compatible with the analyzer, but is compatible with the one saved to disk, red - the current configuration is not compatible with the analyzer and not co ...
... blue - current configuration is compatible with the analyzer, but differs from the one saved to the disk, yellow - the configuration is not compatible with the analyzer, but is compatible with the one saved to disk, red - the current configuration is not compatible with the analyzer and not co ...
LTM4601/LTM4601-1 - 12A DC/DC uModules with PLL, Output Tracking and Margining
... The LTM4601 is a standalone nonisolated switching mode DC/DC power supply. It can deliver up to 12A of DC output current with some external input and output capacitors. This module provides a precisely regulated output voltage programmable via one external resistor from 0.6VDC to 5.0VDC over a 4.5V ...
... The LTM4601 is a standalone nonisolated switching mode DC/DC power supply. It can deliver up to 12A of DC output current with some external input and output capacitors. This module provides a precisely regulated output voltage programmable via one external resistor from 0.6VDC to 5.0VDC over a 4.5V ...
TPS65982 USB Type-C and USB PD Controller, Power Switch and
... – Cable Orientation and Role Detection – Assign CC and VCONN Pins – Advertise Default, 1.5-A or 3-A Current for 5-V USB Type-C Power Port Power Switch – 5-V, 3-A Switch to VBUS for Type-C Power – 5-V to 20-V, 3-A Bidirectional Switch to or from VBUS for USB PD Power – 5-V, 600-mA Switches for VCONN ...
... – Cable Orientation and Role Detection – Assign CC and VCONN Pins – Advertise Default, 1.5-A or 3-A Current for 5-V USB Type-C Power Port Power Switch – 5-V, 3-A Switch to VBUS for Type-C Power – 5-V to 20-V, 3-A Bidirectional Switch to or from VBUS for USB PD Power – 5-V, 600-mA Switches for VCONN ...
TSB41LV06A 数据资料 dataSheet 下载
... transmitter and receiver circuitry presents a high impedance to the cable and does not load the TPBIAS voltage at the other end of the cable. When the TSB41LV06A is used with one or more of the ports not brought out to a connector, the twisted-pair terminals of the unused ports must be terminated fo ...
... transmitter and receiver circuitry presents a high impedance to the cable and does not load the TPBIAS voltage at the other end of the cable. When the TSB41LV06A is used with one or more of the ports not brought out to a connector, the twisted-pair terminals of the unused ports must be terminated fo ...
Axxium™ Pro UPS
... If one power module is removed or for some reason fails, each of the two remaining power modules would supply half of the load, or 2.25 kVA. (In other words, redundancy exists when the load can be supplied by less than all of the installed power modules.) The UPS can be programmed for any level of r ...
... If one power module is removed or for some reason fails, each of the two remaining power modules would supply half of the load, or 2.25 kVA. (In other words, redundancy exists when the load can be supplied by less than all of the installed power modules.) The UPS can be programmed for any level of r ...
nxexp300 expansion unit for feed water and draft control for fireye
... rated, digital inputs along with two line voltage, safety rated digital inputs. When configured via available option parameters, these inputs can be used to simply annunciate conditions, shut the boiler down in the event of a safety related issue, or, other user configurable options. The NXEXP300 in ...
... rated, digital inputs along with two line voltage, safety rated digital inputs. When configured via available option parameters, these inputs can be used to simply annunciate conditions, shut the boiler down in the event of a safety related issue, or, other user configurable options. The NXEXP300 in ...
DESIGN OF A HIGH-SPEED CMOS COMPARATOR Master Thesis in Electronics System at
... of 1 .6 V and the sa m plin g frequ ency of 25 0 M H z. T he com p arato r is d esigne d in a 0.3 5 9 m C M O S process w ith a sup ply voltage of 3.3 V . T he com parator is designed for tim e-in terleaved bandp ass sigm a-delta A D C . D u e to the nature of the target application, it shou ld b e ...
... of 1 .6 V and the sa m plin g frequ ency of 25 0 M H z. T he com p arato r is d esigne d in a 0.3 5 9 m C M O S process w ith a sup ply voltage of 3.3 V . T he com parator is designed for tim e-in terleaved bandp ass sigm a-delta A D C . D u e to the nature of the target application, it shou ld b e ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.