
- Lotus Live Projects
... generate the necessary wave forms to control the frequency of the inverter through proper design of the switching pulse. Spwm or sinusoidal pulse width modulation is widely used in power electronics to digitize the power so that a sequence of voltage pulses can be generated by the on and off of the ...
... generate the necessary wave forms to control the frequency of the inverter through proper design of the switching pulse. Spwm or sinusoidal pulse width modulation is widely used in power electronics to digitize the power so that a sequence of voltage pulses can be generated by the on and off of the ...
DC-DC Converter for Charging Electric Vehicle
... ◦ Overcomes many issues faced by conventional converters ...
... ◦ Overcomes many issues faced by conventional converters ...
End-of-Life Notice Multilin LM10 Motor Protection System GE Digital Energy
... available alternative products for their particular applications (where available). ...
... available alternative products for their particular applications (where available). ...
instructions to tenderers
... of the phase voltage LIN(A, B, C) from the line-to line voltages; channel E switched into channel D for multiplexing. •Filter: Low pass active filter of the 2° order required for the recovery of the fundamental wave out of the PWM signals. Cut-off frequency: 1 kHz. Space vector indicator: •Voltage v ...
... of the phase voltage LIN(A, B, C) from the line-to line voltages; channel E switched into channel D for multiplexing. •Filter: Low pass active filter of the 2° order required for the recovery of the fundamental wave out of the PWM signals. Cut-off frequency: 1 kHz. Space vector indicator: •Voltage v ...
Lab 3: Motor-Pump System Measurements and LabView Interface
... Always remember that water and electricity do not mix. Use extreme caution when transferring the hose from one position to another. Transfer the hose with the system powered down. Use the rags to dry any water that might have splashed or that might be leaking from the pump seals or hose connecti ...
... Always remember that water and electricity do not mix. Use extreme caution when transferring the hose from one position to another. Transfer the hose with the system powered down. Use the rags to dry any water that might have splashed or that might be leaking from the pump seals or hose connecti ...
Auto Service Study Guide Name______________________
... 8. The _______________ system charges the battery & supplies current to all of the car’s electrical systems. 9. The _______________________ is the AC generator that uses engine rotary motion to produce electricity. 10. The _________________ regulator is an electronic device that controls the ch ...
... 8. The _______________ system charges the battery & supplies current to all of the car’s electrical systems. 9. The _______________________ is the AC generator that uses engine rotary motion to produce electricity. 10. The _________________ regulator is an electronic device that controls the ch ...
Introduction - The City University of New York
... friction torque stall torque velocity constant back EMF constant torque constant armature inductance ...
... friction torque stall torque velocity constant back EMF constant torque constant armature inductance ...
Motor Control Functions
... These criteria are used to define one of the following solutions - Direct on line starter - Progressive start-up with soft starters - Start-up at variable speed with variable speed drive (VSD) The step for selecting and dimensioning the power part of the starter will not be developed in this document ...
... These criteria are used to define one of the following solutions - Direct on line starter - Progressive start-up with soft starters - Start-up at variable speed with variable speed drive (VSD) The step for selecting and dimensioning the power part of the starter will not be developed in this document ...
Electrical System
... whose direction reverses cyclically, as opposed to direct current, whose direction remains constant. The usual waveform of an AC power circuit is a sine wave, as this results in the most efficient transmission of energy. However in certain applications different waveforms are used, such as triangula ...
... whose direction reverses cyclically, as opposed to direct current, whose direction remains constant. The usual waveform of an AC power circuit is a sine wave, as this results in the most efficient transmission of energy. However in certain applications different waveforms are used, such as triangula ...
WACKER - 0610065 Internal Vibrator, 5 m hose
... 3-phase high frequency squirrel cage induction motor for connection to e.g. WACKER frequency and voltage converters ...
... 3-phase high frequency squirrel cage induction motor for connection to e.g. WACKER frequency and voltage converters ...
Usual and unusual service (operating) conditions
... does not exceed 10% individually or sum of both when connected directly to utility power (see 12.44 for alternating current motors) 6) Unbalance of supply voltage does not exceed 1% (see 12.45 and 14.36) 7) Not operated in an inclined position. 8) Installation is on a massive ...
... does not exceed 10% individually or sum of both when connected directly to utility power (see 12.44 for alternating current motors) 6) Unbalance of supply voltage does not exceed 1% (see 12.45 and 14.36) 7) Not operated in an inclined position. 8) Installation is on a massive ...
X4 Drives Specification Sheet
... Robust and Reliable The same enclosures that can survive in the harsh industrial world makes them ideal when cleanliness is extremely important, such as the Food and Beverage industry where high pressure washings are needed on a regular basis. The X4 drives, through 100 HP, exceed the specifications ...
... Robust and Reliable The same enclosures that can survive in the harsh industrial world makes them ideal when cleanliness is extremely important, such as the Food and Beverage industry where high pressure washings are needed on a regular basis. The X4 drives, through 100 HP, exceed the specifications ...
Motor Classifications - FE-3000
... ner laminations and insulated them more effectively from each other ...
... ner laminations and insulated them more effectively from each other ...
GFC SERIES Low ProFileTM 400 Hz AND 28 VDC
... and development of reliable solid-state power systems. Through an innovative design, advanced self-diagnostic systems (BITE) and modular construction, Unitron products assure maximum power availability and minimal repair time. The Low ProFileTM Series includes 400 Hz and 28 VDC converters designed t ...
... and development of reliable solid-state power systems. Through an innovative design, advanced self-diagnostic systems (BITE) and modular construction, Unitron products assure maximum power availability and minimal repair time. The Low ProFileTM Series includes 400 Hz and 28 VDC converters designed t ...
78ET-1 - Marine Engineering Study Materials
... steady current it may carry in order to allow a safe margin of 100 per cent overload if it is known to lose heat at the rate of 0.004 cal/sec/sq cm of surface for each Centigrade degree above the ambient temperature of 17OC. The melting point of the wire material is 327OC and the specific resistance ...
... steady current it may carry in order to allow a safe margin of 100 per cent overload if it is known to lose heat at the rate of 0.004 cal/sec/sq cm of surface for each Centigrade degree above the ambient temperature of 17OC. The melting point of the wire material is 327OC and the specific resistance ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.