• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
6 Lead, Single Voltage, Wye Start / Delta Run
6 Lead, Single Voltage, Wye Start / Delta Run

... connected in wye, then reconnected in delta for running condition." This is accomplished by a special Wye-Delta starter configuration using six leads from the motor and is intended to limit the inrush current required to start the motor. Motors designed by US Motors for Wye start, Delta Run may also ...
HO Alternator Specifications—GM CS144 Series
HO Alternator Specifications—GM CS144 Series

AC Induction Motor Slip – What It Is And How To
AC Induction Motor Slip – What It Is And How To

... applications. A number of drive applications still exist, including printing machines, extruders, paper machines, cranes and elevators, in which high static speed accuracy, dynamic speed accuracy or both are required. ...
Homework 5
Homework 5

... is 100W, which consists of 75W dynamic power and 25W static power. Assume that the delay of a gate in the technology is proportional to VDD/(VDD – Vt), where threshold voltage Vt = 0.5V. A low energy mode uses a lower supply voltage and a reduced frequency clock. Determine the voltage and clock freq ...
Budgeting - Learning While Doing
Budgeting - Learning While Doing

... • The stator is the stationary part of the motor’s electromagnetic circuit. The stator core is made up of many thin metal sheets, called laminations. Laminations are used to reduce energy loses that would result if a ...
Universal motor operated drives UM
Universal motor operated drives UM

... Part nr. 776 01001 Weight approx. 0,55kg ...
Iole o Manoa
Iole o Manoa

A-10 - IndiaStudyChannel.com
A-10 - IndiaStudyChannel.com

... load at the terminal voltage of 220V. If the same machine is run as a motor it takes a line current of 20A from 220V supply. The speed of the machine as a motor will be ...
How Electric Motors are made Three phase AC induction motor
How Electric Motors are made Three phase AC induction motor

... The induction motor is probably the most common of all motors. Like the de machine, an induction motor consists of a stator and a rotor, the latter mounted on bearings and separated from the stator by an airgap. The stator core, made up of punchings (or laminations), carries slot-embedded conductor ...
Product Life Cycle Report:
Product Life Cycle Report:

... from the zero-detection circuitry. The DSP uses these signals to adjust the voltage phase such that the signal from the inverter can be synchronized with the voltage signals on the AMPS. Once synchronized, the phase angle is adjusted to control the power flow from the fuel cell to the AMPS, completi ...
Technical Information CR EB4 N Motor Controller
Technical Information CR EB4 N Motor Controller

... software package the Horiso Smart Motor Control that provides safety soft limits (prevents damage if motor limits fail). Precise facade element/s adjustment in angle degree or mm for facade uniformity, preset stops, programmable parameters and basic scheduling. In addition to controlling 4 motors, e ...
the manual - OpenBuilds Part Store
the manual - OpenBuilds Part Store



... loaded, it creates a higher harmonic content than at full load. A swing choke increases its inductance when the current passing through it is lower, usually due to partial loading. This increased inductance reduces the harmonics as a percent of load current. ...
Experimental Results of Variable Frequency Drive for Three Phase
Experimental Results of Variable Frequency Drive for Three Phase

TRANSIENT RESPONSE OF A WIND ENERGY CONVERSION
TRANSIENT RESPONSE OF A WIND ENERGY CONVERSION

Abstract - Logic Mind Technologies
Abstract - Logic Mind Technologies

... Performance Evaluation of a Low Power Solar-PV Energy System with SEPIC Converter. Abstract This paper presents the design and performance of a low power stand-alone solar photovoltaic (PV) energy generating system. The system is designed considering solar-PV panels of 750W to feed an average load d ...
There are inherent problems in single-supply op
There are inherent problems in single-supply op

A New Induction Motor V/F Control Method using Dspic30f5011
A New Induction Motor V/F Control Method using Dspic30f5011

... of this work is to first convert the line voltage AC into DC. DC is again converted to single/three phase AC as per load requirements. The output voltage, frequency or both of inverter can be controlled by the application of power electronics and digital signal controller. The output voltage wavefor ...
Sample Specification PowerFlex 70 Enhanced Control GENERAL
Sample Specification PowerFlex 70 Enhanced Control GENERAL

... The monitoring mode provides the following information on the display all at the same time (doesn’t require jumping between screens) 1. A status line indicating direction, status, fault / alarm conditions and Auto / Manual mode. 2. Three additional lines that may be programmed for at least 20 diffe ...
Document
Document

...  DDRX ----> Sets whether a pin is Input or Output of PORTX.  PORTX ---> Sets the Output Value of PORTX.  PINX -----> Reads the Value of PORTX. ...
Electric Drives
Electric Drives

... Regenerative braking is not possible since the field current needs to be maintained but it collapses when the rotor current passes through zero and reverses. ...
Best insulation material for VFD cab n material for VFD cables
Best insulation material for VFD cab n material for VFD cables

... Many electrical contractors use PVC/Nylon (THHN) wiring in conduit or THHN power tray cables to connectt Pulse Width Modulation (PWM) d drives to the motor. However, PVC is not a good insulator for this application. The dielectric strength, the capacitance and ...
Speed Control With Low Armature Loss for Very Small Sensorless
Speed Control With Low Armature Loss for Very Small Sensorless

Franklin Pumptec Brochure
Franklin Pumptec Brochure

GLG-60 series
GLG-60 series

... 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Constant current operation region is within announced range. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements ...
< 1 ... 1290 1291 1292 1293 1294 1295 1296 1297 1298 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.