• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DC Motor Reversing
DC Motor Reversing

Lab #7: LVDT - Montana State University
Lab #7: LVDT - Montana State University

What Is Sumo Robot? Sumo robot is an electronic device which is
What Is Sumo Robot? Sumo robot is an electronic device which is

OSI
OSI

... Currents up to 5 Amperes and voltages up to 600Vac can be directly connected to the DW5. The DW5 can be used with OSI metering class current transformers for measurements up to 10 kiloamperes. Specific outputs can be selected to interface with any data acquisition system from a simple recorder to co ...
Presentación de PowerPoint - cei@upm
Presentación de PowerPoint - cei@upm

... account the power losses and size of semiconductors and magnetic components to find the optimal design. This method helps during the design when it is necessary to make a trade-off between the efficiency and power density. The proposed method has been validated and the implemented converter has effi ...
Example 5 Solution
Example 5 Solution

... A 2000-hp, 2300-V, unity power factor, Y-connected, 30pole, 60-Hz synchronous motor has a synchronous reactance of 1.95 W/phase. Neglect all losses. Compute the maximum power and torque which this motor can deliver if it is supplied with power directly from a 60-Hz, 2300-V supply. Assume field excit ...
Quasar Electronics – www.QuasarElectronics.com
Quasar Electronics – www.QuasarElectronics.com

... The Stepper Motor Chopper Driver can be used with a power supply up to 36V, however, if the power supply voltage is above 25V a second power supply less than 26V is required to produce 5V for the logic. Connect the motor power supply negative wire to a COM terminal and positive wire to the Vs termin ...
Basic Information and Definitions
Basic Information and Definitions

... ... of a proximity switch is the voltage to which the isolation tests and the creep distances are referenced. For proximity switches the highest rated operating voltage must be considered as the rated isolation voltage. ...
Paper Title (use style: paper title) - ePrints
Paper Title (use style: paper title) - ePrints

... device to provide lower losses at higher frequencies [37]. Although this being the case SiC poses some significant advantages over GaN (other than its commercial readiness) in power device application for a number of reasons. In particular, the cost of manufacturing GaN wafers is significantly highe ...
4113 datasheet - Copley Controls
4113 datasheet - Copley Controls

... Parallel operation External resistor operation optional for higher continuous power ...
wound rotor machine fed by a single-phase grid
wound rotor machine fed by a single-phase grid

... This paper proposes a novel energy conversion system for variable speed drives. It consists of a wound rotor machine and an inverter without any rectifier and input filter. ac–ac energy conversion systems with regenerative capability have been widely applied for adjustable speed operation of electri ...
Faults Simulation Trainer in Electrical Motors ESAM www.edibon.com
Faults Simulation Trainer in Electrical Motors ESAM www.edibon.com

... Technical Teaching Equipment ...
Wind energy powered Vehicle
Wind energy powered Vehicle

... force, which states that any current carrying conductor placed within an external magnetic field experiences a torque or force known as Lorentz force. Advantages of a brushed DC motor include low initial cost, high reliability, and simple control of motor speed. Disadvantages are high maintenance an ...
KBMD DC MOTOR SPEED CONTROL QUICK
KBMD DC MOTOR SPEED CONTROL QUICK

... result in a reduction of the available maximum speed. Also, if the motor is not an SCR rated type, the actual AC line current at full load and full speed should not exceed the motor’s DC nameplate current rating. ...
praktyczna diagnostyka maszyn indukcyjnych klatkowych
praktyczna diagnostyka maszyn indukcyjnych klatkowych

... investigated drive coal mills, air blasters, water-feed pumps and smoke exhausters. Diagnoses of the state of their cages are accounted for by scheduling reparations of these machines. Assessment of cage states was based on measurements of the magnitude of the (1±2s)f0 current components, where: s – ...
How to control multiple voltages with the Room Controller
How to control multiple voltages with the Room Controller

... The Room Controller is typically connected to a single feeding 20A circuit which powers the controller and the controlled loads. In the event that your application requires mixed voltages, an alternative voltage switchpack may be connected to the Room Controller. Any Greengate switchpack may be wire ...
G540 User Manual
G540 User Manual

... current set resistor may be a 1/4 Watt, 5% part. Finally have a STEP and DIRECTION pulse source available. STEP 1: CONNECT POWER Connect your power supply positive to TERMINAL 11 and negative to TERMINAL 12. The power supply voltage is determined by multiplying the square root of the motor’s inducta ...
Electric Motors
Electric Motors

Routout CNC Microstepping Bipolar Stepper Motor Driver (Opto
Routout CNC Microstepping Bipolar Stepper Motor Driver (Opto

... The Routout CNC stepper motor driver is a single axis, pulse width modulated (PWM), Microstepping Bipolar driver with Full / Half / Quarter / Eighth stepping capabilities and optocoupled step and direction inputs. ...
File
File

File
File

LAB 12 OVERVIEW: WORK DONE BY A MOTOR 6/97 An electric
LAB 12 OVERVIEW: WORK DONE BY A MOTOR 6/97 An electric

line
line

... require 5-10 mA while motors require 150 mA and above so Motor Driver is used . • For driving motor at different rpm by using PWM ...
DP31778783
DP31778783

... the effect of a continuously varying analog signal. This PWM conversion generally has very high electrical efficiency and can be used in controlling either a three-phase synchronous motor or a threephase induction motor .It is desirable to create three perfectly sinusoidal current waveforms in the m ...
Chapter 4
Chapter 4

< 1 ... 1275 1276 1277 1278 1279 1280 1281 1282 1283 ... 1315 >

Variable-frequency drive



A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report