Download 4113 datasheet - Copley Controls

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Three-phase electric power wikipedia , lookup

Electrification wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Audio power wikipedia , lookup

Rectifier wikipedia , lookup

Voltage regulator wikipedia , lookup

Metadyne wikipedia , lookup

History of electric power transmission wikipedia , lookup

Power MOSFET wikipedia , lookup

Stray voltage wikipedia , lookup

Power engineering wikipedia , lookup

Power electronics wikipedia , lookup

Distributed generation wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Opto-isolator wikipedia , lookup

Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup

Distribution management system wikipedia , lookup

Buck converter wikipedia , lookup

AC adapter wikipedia , lookup

Surge protector wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Transcript
MODEL 125, 145
PWM REVERSE ENERGY DISSIPATOR
FEATURES
•
•
•
•
•
•
Energy dissipation ratings
1200 W·s @ 187Vdc
1600 W·s @ 375 Vdc
MODEL
PEAK CURRENT
125
145
30A @ 187 Vdc
20A @ 375 Vdc
Standard trip voltage
187VDC or 375VDC
UL 508C, Fully isolated, works
with off line power supplies
Custom configurations
available (contact factory)
Parallel operation
External resistor operation
optional for higher continuous
power
PRODUCT DESCRIPTION
The reverse energy dissipator
functions as a shunt regulator that
limits the rise in power supply
voltage, during regeneration. When
a motor is braking or a stage is
lowering, energy is transferred from
the motor to the supply capacitor
causing the voltage to increase.
In high power systems it may be
impractical to use capacitance to
absorb all the energy.The model
125 and 145 can be used to
dissipate the energy as the voltage
reaches a set limit.
Under normal forward running
conditions, the PWM dissipator is
inoperative. Only when braking
occurs, increasing the power supply
voltage does the PWM dissipator
start to dissipate energy. When the
trip point is reached the PWM duty
cycle starts to increase and energy
is dissipated over its resistive load.
As the voltage increases, the duty
cycle increases, linearly dissipating
more energy over its internally set
operating range
The range is directly proportional to
the trip voltage (4% of Trip point).
The green LED indicates power OK,
the yellow LED indicates dumping,
and the red LED indicates
overtemperature and shutdown.
For dissipating more energy
the Model 125 and 145 can be
connected in parallel for
simultaneous operation.
POWER OK
REGEN
FAULT
J1
+
-
FRAME
GROUND
DC
INPUT
EXTERNAL
REGEN
RESISTOR
STATUS
+
MOTOR
+
H
N
BUSS
-
1
2
3
4
5
6
7
+
BUSS R EXT STATUS
+
AC
J1
U
V
W
1
2
3
4
5
6
7
8
9
J3
J2
Model 125 or 145
Dissipator
Copley Controls Corp., 20 Dan Road, Canton, MA 02021
www.copleycontrols.com
Copley Amplifier
Tel: 781-828-8090
Fax: 781-828-1750
Page 1 of 2
MODEL 125, 145
PWM REVERSE ENERGY DISSIPATOR
SPECIFICATIONS
POWER CURVES FOR MODEL 145 (125)
MODEL
125
145
30A @ 200V
20A @ 400V
PEAK POWER
6k Watts * 200 ms
8k Watts * 200 ms
PEAK ENERGY
1200 W·s
1600 W·s
CONTINUOUS POWER
(See note 2)
120 Watts
160 Watts
V >= 390V (195V)
PEAK CURRENT
8k W (6k W)
Typical V < 390V (195V)
Watts
160 W (120 W)
0.2 s
20A (30A)
OPERATING VOLTAGE
Trip point
Range
Stability
>10 s
Time
187V
7.5V
0.2%
375V
15V
0.2%
< 30 mA
< 30 mA
Amps
0.4A (0.6A)
QUIESCENT CURRENT
375V (187V)
THERMAL REQUIREMENTS
operating temperature
Storage temperature
400V (200V)
Volts
0°C to 70° C
-30°C to 85°C
0°C to 70° C
-30°C to 85° C
OUTLINE DIMENSIONS
INDICATOR LED’s
Green
Yellow
Yellow & Red
Red
390V (195V)
7.5 (190.5)
7.0 (177.8)
Power OK
Dissipating Energy
Warning, 1° C from thermal shutdown
Thermal shutdown
0.93 (23.62)
4.85
3.0 (123.2)
(76.2)
STATUS
Opto-isolator is ON (4mA current) when dissipator is OK.
OFF (32VDC max) when shutdown.
APPLICATION INFORMATION
•
The operating range voltage is 4% of the trip voltage.
Where multiple dissipators are configured in parallel,
use cable with equal length to the amplifier.
STATUS
DC
INPUT
EXTERNAL
REGEN
RESISTOR
-
-
+
+
-
+
1
2
3
4
5
6
7
++
J1
•
Special configurations are available for
non-standard trip voltages.
POWER OK
REGEN
FAULT
•
FRAME
GROUND
7.0 (177.8)
1.46
(37.08)
2.72
(69.1)
BUSS R EXT STATUS
Dimensions in inches (mm)
WEIGHT
0.84 lbs. (0.38kg)
CONNECTORS
J1: 7-position barrier strip; #6-32 screws with wire protectors
ORDERING GUIDE
Model 125
Model 145
187V trip, 30A Peak PWM reverse energy dissipator
375V trip, 20A Peak PWM reverse energy dissipator
Note:
1. For special configurations, specify the trip voltage and verify that the range voltage is OK.
2. To increase continuous power dissipation, contact factory for external resistor option.
Corporate Office, USA
20 Dan Road
Canton, MA 02021
Tel: 781-828-8090
Fax: 781-828-1750
Rev D, 10/29/03