* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 4113 datasheet - Copley Controls
Three-phase electric power wikipedia , lookup
Electrification wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Audio power wikipedia , lookup
Voltage regulator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power MOSFET wikipedia , lookup
Stray voltage wikipedia , lookup
Power engineering wikipedia , lookup
Power electronics wikipedia , lookup
Distributed generation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Opto-isolator wikipedia , lookup
Life-cycle greenhouse-gas emissions of energy sources wikipedia , lookup
Distribution management system wikipedia , lookup
Buck converter wikipedia , lookup
Surge protector wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
MODEL 125, 145 PWM REVERSE ENERGY DISSIPATOR FEATURES • • • • • • Energy dissipation ratings 1200 W·s @ 187Vdc 1600 W·s @ 375 Vdc MODEL PEAK CURRENT 125 145 30A @ 187 Vdc 20A @ 375 Vdc Standard trip voltage 187VDC or 375VDC UL 508C, Fully isolated, works with off line power supplies Custom configurations available (contact factory) Parallel operation External resistor operation optional for higher continuous power PRODUCT DESCRIPTION The reverse energy dissipator functions as a shunt regulator that limits the rise in power supply voltage, during regeneration. When a motor is braking or a stage is lowering, energy is transferred from the motor to the supply capacitor causing the voltage to increase. In high power systems it may be impractical to use capacitance to absorb all the energy.The model 125 and 145 can be used to dissipate the energy as the voltage reaches a set limit. Under normal forward running conditions, the PWM dissipator is inoperative. Only when braking occurs, increasing the power supply voltage does the PWM dissipator start to dissipate energy. When the trip point is reached the PWM duty cycle starts to increase and energy is dissipated over its resistive load. As the voltage increases, the duty cycle increases, linearly dissipating more energy over its internally set operating range The range is directly proportional to the trip voltage (4% of Trip point). The green LED indicates power OK, the yellow LED indicates dumping, and the red LED indicates overtemperature and shutdown. For dissipating more energy the Model 125 and 145 can be connected in parallel for simultaneous operation. POWER OK REGEN FAULT J1 + - FRAME GROUND DC INPUT EXTERNAL REGEN RESISTOR STATUS + MOTOR + H N BUSS - 1 2 3 4 5 6 7 + BUSS R EXT STATUS + AC J1 U V W 1 2 3 4 5 6 7 8 9 J3 J2 Model 125 or 145 Dissipator Copley Controls Corp., 20 Dan Road, Canton, MA 02021 www.copleycontrols.com Copley Amplifier Tel: 781-828-8090 Fax: 781-828-1750 Page 1 of 2 MODEL 125, 145 PWM REVERSE ENERGY DISSIPATOR SPECIFICATIONS POWER CURVES FOR MODEL 145 (125) MODEL 125 145 30A @ 200V 20A @ 400V PEAK POWER 6k Watts * 200 ms 8k Watts * 200 ms PEAK ENERGY 1200 W·s 1600 W·s CONTINUOUS POWER (See note 2) 120 Watts 160 Watts V >= 390V (195V) PEAK CURRENT 8k W (6k W) Typical V < 390V (195V) Watts 160 W (120 W) 0.2 s 20A (30A) OPERATING VOLTAGE Trip point Range Stability >10 s Time 187V 7.5V 0.2% 375V 15V 0.2% < 30 mA < 30 mA Amps 0.4A (0.6A) QUIESCENT CURRENT 375V (187V) THERMAL REQUIREMENTS operating temperature Storage temperature 400V (200V) Volts 0°C to 70° C -30°C to 85°C 0°C to 70° C -30°C to 85° C OUTLINE DIMENSIONS INDICATOR LED’s Green Yellow Yellow & Red Red 390V (195V) 7.5 (190.5) 7.0 (177.8) Power OK Dissipating Energy Warning, 1° C from thermal shutdown Thermal shutdown 0.93 (23.62) 4.85 3.0 (123.2) (76.2) STATUS Opto-isolator is ON (4mA current) when dissipator is OK. OFF (32VDC max) when shutdown. APPLICATION INFORMATION • The operating range voltage is 4% of the trip voltage. Where multiple dissipators are configured in parallel, use cable with equal length to the amplifier. STATUS DC INPUT EXTERNAL REGEN RESISTOR - - + + - + 1 2 3 4 5 6 7 ++ J1 • Special configurations are available for non-standard trip voltages. POWER OK REGEN FAULT • FRAME GROUND 7.0 (177.8) 1.46 (37.08) 2.72 (69.1) BUSS R EXT STATUS Dimensions in inches (mm) WEIGHT 0.84 lbs. (0.38kg) CONNECTORS J1: 7-position barrier strip; #6-32 screws with wire protectors ORDERING GUIDE Model 125 Model 145 187V trip, 30A Peak PWM reverse energy dissipator 375V trip, 20A Peak PWM reverse energy dissipator Note: 1. For special configurations, specify the trip voltage and verify that the range voltage is OK. 2. To increase continuous power dissipation, contact factory for external resistor option. Corporate Office, USA 20 Dan Road Canton, MA 02021 Tel: 781-828-8090 Fax: 781-828-1750 Rev D, 10/29/03 Page 2 of 2