GSR - switching regulator modules High-efficiency step-down switching regulator modules
... GS-R12F and 500 kHz for GS-R12FP. The GSR modules include all the components required to drive the ST embedded regulator, providing a plug and play-like point of regulation. The main features common to the GSR family are: pulse-by-pulse and frequency foldback current protection, overvoltage protecti ...
... GS-R12F and 500 kHz for GS-R12FP. The GSR modules include all the components required to drive the ST embedded regulator, providing a plug and play-like point of regulation. The main features common to the GSR family are: pulse-by-pulse and frequency foldback current protection, overvoltage protecti ...
Micropower Circuit Monitors Positive Supply
... Abstract: The following application note shows a circuit that converts the load current of a positive power supply into a ground referenced signal voltage using the ICL7612 operational amplifier. The inexpensive circuit of Figure 1 converts the load current of a positive power supply to a groundrefe ...
... Abstract: The following application note shows a circuit that converts the load current of a positive power supply into a ground referenced signal voltage using the ICL7612 operational amplifier. The inexpensive circuit of Figure 1 converts the load current of a positive power supply to a groundrefe ...
Voltage drop in cables
... Voltage drop in cables In any cable that is carrying a current, it is inevitable that a certain amount of voltage drop occurs. This is due to the resistance of the cable itself and the current flowing in it. Voltage drop in cable (V) = Resistance of cable (R) X Current through cable ( I ) Whenever a ...
... Voltage drop in cables In any cable that is carrying a current, it is inevitable that a certain amount of voltage drop occurs. This is due to the resistance of the cable itself and the current flowing in it. Voltage drop in cable (V) = Resistance of cable (R) X Current through cable ( I ) Whenever a ...
Daily Constant PV Output Power Supplying AC Pumps
... with threatening climate change the use of these must arguably decrease. The power generation is globally the largest source of green-house gases and, preferably, the generation should be shifted to more renewable sources. Solar power is often regarded as one of the most promising energy sources for ...
... with threatening climate change the use of these must arguably decrease. The power generation is globally the largest source of green-house gases and, preferably, the generation should be shifted to more renewable sources. Solar power is often regarded as one of the most promising energy sources for ...
ABB Oy AC Drive efficiency and loss estimation Example, quadratic
... have always some tolerances which shall be recognized as well as the size of penalty. This guide helps you to report typical and worst case losses using DriveSize sales/engineering tool. Worst-case losses include reasonable tolerances, which are described in this guide. In projects where efficiency ...
... have always some tolerances which shall be recognized as well as the size of penalty. This guide helps you to report typical and worst case losses using DriveSize sales/engineering tool. Worst-case losses include reasonable tolerances, which are described in this guide. In projects where efficiency ...
Applications of Variable Speed Drives
... of variable speed control. The savings related to the use of variable speed control are dependent on the control system that is being replaced. In Fig. 7 the energy savings achieved by fitting a VSD to a rotary screw compressed air unit, compared to other methods of flow control at partial load, can ...
... of variable speed control. The savings related to the use of variable speed control are dependent on the control system that is being replaced. In Fig. 7 the energy savings achieved by fitting a VSD to a rotary screw compressed air unit, compared to other methods of flow control at partial load, can ...
energy discharge capacitors uctance sangamo electric - sonar-info
... and the dissipation factor of standord units ore measured on a Generai Radio 161 IA bridge or equivalent at a frequency of 60 cycles per second and referred to a temperature of 25°C. The voltage rating of each unit is the peak d-c voltage to which the capacitors ore to be chorged. The chorging ti me ...
... and the dissipation factor of standord units ore measured on a Generai Radio 161 IA bridge or equivalent at a frequency of 60 cycles per second and referred to a temperature of 25°C. The voltage rating of each unit is the peak d-c voltage to which the capacitors ore to be chorged. The chorging ti me ...
WLA- Load balancing unit - PT Sinar Elektrindo Perkasa
... proportional regulation of the nominal value for several generating sets in parallel can be effected. This balancer is often combined with the frequency control unit "FN 1" and the synchronizer unit "SY 1" for a fully automatic synchronization with load balancing. Output impulses for speed governor ...
... proportional regulation of the nominal value for several generating sets in parallel can be effected. This balancer is often combined with the frequency control unit "FN 1" and the synchronizer unit "SY 1" for a fully automatic synchronization with load balancing. Output impulses for speed governor ...
50W - 100W, Rugged, Ultra-compact, Industrial DC/DC Converter
... The MIM 105 Series rugged, industrial quality DC/DC converter uses a field proven design to generate up to 100W output power, depending on input/output configuration. It is a mature product with a track record in numerous applications. This converter is a complete turn-key unit with input filter, ho ...
... The MIM 105 Series rugged, industrial quality DC/DC converter uses a field proven design to generate up to 100W output power, depending on input/output configuration. It is a mature product with a track record in numerous applications. This converter is a complete turn-key unit with input filter, ho ...
150LECTURE20 POWER SUPPLIES Lecture Notes Page
... referred to as power supply. Of course, it does not really supply power, it just converts it, so "converter" is a more accurate term for such a device. A typical application of a DC power supply unit (PSU) is to convert AC voltage into regulated DC voltages required for electronic equipment. Origina ...
... referred to as power supply. Of course, it does not really supply power, it just converts it, so "converter" is a more accurate term for such a device. A typical application of a DC power supply unit (PSU) is to convert AC voltage into regulated DC voltages required for electronic equipment. Origina ...
No Slide Title
... • DC voltages are usually lower, and therefore safer (e.g., 24V). • DC inputs are very fast, AC inputs require a longer on-time. • DC voltages can be connected to more electrical systems. • AC signals are more immune to noise than DC. • AC power is easier and less expensive to supply to equipment. • ...
... • DC voltages are usually lower, and therefore safer (e.g., 24V). • DC inputs are very fast, AC inputs require a longer on-time. • DC voltages can be connected to more electrical systems. • AC signals are more immune to noise than DC. • AC power is easier and less expensive to supply to equipment. • ...
170M____
... is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bu ...
... is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bu ...
AMS4155 数据手册DataSheet 下载
... • Thermal Shutdown • Cycle-by-cycle + hiccup Over Current Protection • Under Voltage Lockout • Frequency Synchronization Input • Operating Temperature: -40°C to 125°C • Available in an 8-Pin SO Package ...
... • Thermal Shutdown • Cycle-by-cycle + hiccup Over Current Protection • Under Voltage Lockout • Frequency Synchronization Input • Operating Temperature: -40°C to 125°C • Available in an 8-Pin SO Package ...
Test Procedure for the LV5683PGEVB Evaluation Board SANYO Semiconductors
... Line regulation is defined as the maximum change in output voltage as the input voltage is varied through the specified range. It is measured by changing the input voltage and measuring the minimum/maximum voltage of the output. Line regulation is defined as the difference between maximum and minimu ...
... Line regulation is defined as the maximum change in output voltage as the input voltage is varied through the specified range. It is measured by changing the input voltage and measuring the minimum/maximum voltage of the output. Line regulation is defined as the difference between maximum and minimu ...
PDF Print Version - Glassman High Voltage
... The PG Series is available in two configurations ... as a standard PG Series supply or as an ultra-low ripple PG-LR Series for demanding applications, such as particle accelerators. Shown is the dual-stack PG-LR Series with remote control unit. One stack serves as a high voltage multiplier while the ...
... The PG Series is available in two configurations ... as a standard PG Series supply or as an ultra-low ripple PG-LR Series for demanding applications, such as particle accelerators. Shown is the dual-stack PG-LR Series with remote control unit. One stack serves as a high voltage multiplier while the ...
STK4050II AF Power Amplifier (Split Power Supply) (200W
... Anyone purchasing any products described or contained herein for an above-mentioned use shall: Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors and all their officers and employees, jointly and severally, against any and all ...
... Anyone purchasing any products described or contained herein for an above-mentioned use shall: Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors and all their officers and employees, jointly and severally, against any and all ...
NJM723
... error amplefier, power-series pass transistor and current-limit circuitry. Additional NPN or PNP pass elements may be used when output currents exceeding 150mA are required. In addition to the above, the device features low standby current drain, low temperature drift and high ripple rejection. The ...
... error amplefier, power-series pass transistor and current-limit circuitry. Additional NPN or PNP pass elements may be used when output currents exceeding 150mA are required. In addition to the above, the device features low standby current drain, low temperature drift and high ripple rejection. The ...
LED DimmingDriver - JLC-Tech
... Design to work with a standard 0-10V controller. A wall box controller will only go from 10V down to 0.7V – the light output will go from 100% to 8% and will not turn off completely unless AC power is disconnected, this is needed for energy saving. When using 0-10V controller, it should go from 10V ...
... Design to work with a standard 0-10V controller. A wall box controller will only go from 10V down to 0.7V – the light output will go from 100% to 8% and will not turn off completely unless AC power is disconnected, this is needed for energy saving. When using 0-10V controller, it should go from 10V ...
LK3420692075
... transformed into a reference frame in which the dynamic behave like DC quantities. The decoupling control between the flux and torque allows induction motor to achieve fast transient response. Therefore, it is preferred used in high performance motor applications. Nevertheless the performance of the ...
... transformed into a reference frame in which the dynamic behave like DC quantities. The decoupling control between the flux and torque allows induction motor to achieve fast transient response. Therefore, it is preferred used in high performance motor applications. Nevertheless the performance of the ...
Spindle Drive System Troubleshooting
... 17) Drive Bypass - You can bypass the drive and run the motor directly from a 230 VAC 3 phase supply. In bypassing the drive, this will help determine if the wiring and/or the motor are fine. Remove the spindle belt or disconnect the air supply and retract both idlers. Disconnect the motor wires (T1 ...
... 17) Drive Bypass - You can bypass the drive and run the motor directly from a 230 VAC 3 phase supply. In bypassing the drive, this will help determine if the wiring and/or the motor are fine. Remove the spindle belt or disconnect the air supply and retract both idlers. Disconnect the motor wires (T1 ...
Bipolar transistors II, Page 1 Bipolar Transistors II
... Bipolar transistors II, Page 3 Plot V vs. I for this supply by loading it. Choose several load resistors from 2kΩ to 100Ω. As the current increases do you note any change in the curve? If yes, comment on possible reasons. Note: The zener-regulated pass transistor developed in this lab is an accepta ...
... Bipolar transistors II, Page 3 Plot V vs. I for this supply by loading it. Choose several load resistors from 2kΩ to 100Ω. As the current increases do you note any change in the curve? If yes, comment on possible reasons. Note: The zener-regulated pass transistor developed in this lab is an accepta ...
Variable-frequency drive

A variable-frequency drive (VFD) (also termed adjustable-frequency drive, variable-speed drive, AC drive, micro drive or inverter drive) is a type of adjustable-speed drive used in electro-mechanical drive systems to control AC motor speed and torque by varying motor input frequency and voltage.VFDs are used in applications ranging from small appliances to the largest of mine mill drives and compressors. However, around 25% of the world's electrical energy is consumed by electric motors in industrial applications, which are especially conducive for energy savings using VFDs in centrifugal load service, and VFDs' global market penetration for all applications is still relatively small. That lack of penetration highlights significant energy efficiency improvement opportunities for retrofitted and new VFD installations.Over the last four decades, power electronics technology has reduced VFD cost and size and has improved performance through advances in semiconductor switching devices, drive topologies, simulation and control techniques, and control hardware and software.VFDs are available in a number of different low- and medium-voltage AC-AC and DC-AC topologies.