• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
EGH 681: Room transducer, relative humidity and temperature
EGH 681: Room transducer, relative humidity and temperature

... the higher the operating voltage, the greater the power loss. This power loss must be taken into account in the temperature measurement. At a fixed operating voltage (±0.2 V), this is normally done by adding or subtracting a constant offset value. The room transducers have a variable operating volta ...
High-Frequency Link: A Solution for Using Only One DC Source in
High-Frequency Link: A Solution for Using Only One DC Source in

... and the smaller or auxiliary (aux) H-bridges return power at some operation ranges (voltage amplitudes), even when the machine is motoring; therefore, auxiliary H-bridges must be bidirectional [12], [13]. Some solutions to overcome CHB and ACHB drawbacks have been proposed, such as the use of floati ...
Article
Article

... the MEG Experiment at PSI, Switzerland. This experiment searches for the lepton-flavor violating decay +  e+ with a sensitivity down to 10-13. After a first prototype (DRS1), the second prototype (DRS2) has been fabricated in a 0.25 m CMOS process and successfully been tested. It contains 10 cha ...
Common Power Supply Topologies
Common Power Supply Topologies

Chapter 2 Data Communication Concepts
Chapter 2 Data Communication Concepts

... – Clock circuitry – One to four synchronization characters (SYN) for each block of data at the beginning and end – More efficient – Mainframe computer ...
“1”. - Peter Eggington
“1”. - Peter Eggington

Test report of plants of over 16A and max 75 A
Test report of plants of over 16A and max 75 A

... Can the system start and produce continuously within the normal production area only limited by protection settings mentioned below in 2.7 ? ...
Panamax | #1 in power protection
Panamax | #1 in power protection

... Two switched, high current outlets controlled by the front panel Power Button or the DC Trigger input. Bank 3 has a 5 second turn on delay and turns off immediately. The High Current outlet provides power from a low impedance noise filtration circuit that does not limit the current to your equipment ...
Probably the Simplest GPS Disciplined Oscillator possible
Probably the Simplest GPS Disciplined Oscillator possible

... time. Initially I was sceptical thinking it probably only consisted of 10000 pulses per second - which could have been no better than the 1 PPS signal itself in the short term. However, after making extensive measurements, came to the conclusion it really was quite a respectable signal - in particul ...
VNI4140K
VNI4140K

... the device also integrates case temperature detection (TCSD) and protection, related to the whole device dissipation. This additional protection avoids PCB degradation in the case of a large number of channels in overload conditions, which would lead to a rapid increase in case temperature. ...
Saftronics Inc.
Saftronics Inc.

... *3 Voltages greater than the source voltage cannot be output. *4 Amperage values in parentheses ( ) are applicable to operation with 3 kHz or lower carrier frequencies (F26 = 3 or less). These values also apply when the ambient temperaute is below 40°C . *5 Tests at standard load conditions (85% loa ...
7B21 数据手册DataSheet 下载
7B21 数据手册DataSheet 下载

... The modules feature a maximum nonlinearity of +0.02% and are factory calibrated to guarantee a maximum accuracy specification of +0.1%. The 7B Series offers up to 1500 V rms continuous common mode voltage isolation and 120 V rms of field wiring input protection. The power supplies necessary to drive ...
CBM Modules
CBM Modules

... In the example above the CBM/1 and /8 modules would be suitable while the CBM/8/35mm would not be. DC Circuits When the control transformer provides power to an AC/DC power supply which then supplies DC power to protective devices the maximum fault current available from the power supply should be k ...
Read AD589 Datasheet
Read AD589 Datasheet

... the end user to keep power off when not needed and yet respond quickly when the power is turned on for operation. Figure 3 displays the turn-on characteristics of the AD589. This characteristic is generated from cold-start operation and represents the true turnon waveform after an extended period wi ...
PES Instruction Manual - CIS Elektrotechnik GmbH
PES Instruction Manual - CIS Elektrotechnik GmbH

... into a load-independent direct-current and direct-voltage signal. The calibrated double-outputs can be switched over between 0-20 mA / 0-10 V and 4-20 mA / 2-10 V. ...
14PE12 A Solar Power Generation System With a Seven
14PE12 A Solar Power Generation System With a Seven

Chapter 7 Phinney 3-13
Chapter 7 Phinney 3-13

... classical motor speed control systems (like old elevators), but power hungry. The required heater filaments need hundreds of watts of continuous power. This was no serious problem for systems intending to operate from utility lines, but for a battery powered system is was the kiss of death. Yes, thi ...
Multi-functional Packaged Antennas for Next
Multi-functional Packaged Antennas for Next

Product Datasheet
Product Datasheet

... NVE's family of high-speed digital isolators are CMOS devices created by integrating active circuitry and our GMR-based and patented* IsoLoop® technology. The IL715, IL716 and IL717 are four channel versions of the world's fastest digital isolator with a 110 Mbaud data rate. These devices provide th ...
1400-104 Relative Humidity/Air Temperature - LI
1400-104 Relative Humidity/Air Temperature - LI

... It is not necessary to send the 1400-104 sensor back to LI-COR for recalibration, as calibration of the RH sensor is done simply by replacing the sensor element. ...
pulse king - GreenerEnergy.ca
pulse king - GreenerEnergy.ca

... proportional to the number of delay elements comprising the ring. A ring oscillator that is based on single-ended signaling typically includes an odd number of delay elements greater than or equal to three. For many applications, such as data communications, ring oscillators with higher oscillation ...
X5000A3
X5000A3

DMR-203
DMR-203

Power Control Devices
Power Control Devices

Lecture 1
Lecture 1

< 1 ... 959 960 961 962 963 964 965 966 967 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report