• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
The black start procedures should contain the following
The black start procedures should contain the following

... should be started up and islands formed around these generating stations by connecting essential loads. These islands are then interconnected at predefined locations where synchronizing facilities are available. The speed of restoration enhances with increase in number of black start facilities and ...
Voltage Sag Mitigation in Distribution Line using DSTATCOM
Voltage Sag Mitigation in Distribution Line using DSTATCOM

Voltage Sag Ride Through Mitigation
Voltage Sag Ride Through Mitigation

... boost transformers in combination with parametric filters to provide regulated sinusoidal output even with nonlinear loads typical of computer systems. The cost for 15kVA to 125kVA ranges between $20k and $50k. These are custom designs for each installation. Typical tap changing voltage regulators d ...
DESIGN OF CONTROL CIRCUIT FOR AN INVERTER
DESIGN OF CONTROL CIRCUIT FOR AN INVERTER

Welcome to this module on regulated power supplies. This
Welcome to this module on regulated power supplies. This

... The Boost converter is used in DC-to-DC step-up voltage control applications where an output voltage greater than the input voltage is required. The initial boost converter state has the input voltage (Vin) applied with the switch OPEN and a load connected, the diode (D1) is forward biased causing l ...
MAX1582/MAX1582Y High-Efficiency Step-Up Converters for White LED Main and Subdisplay Backlighting General Description
MAX1582/MAX1582Y High-Efficiency Step-Up Converters for White LED Main and Subdisplay Backlighting General Description

... OVLO occurs when VOUT1 rises above 27V (18V for the MAX1582Y). The protection circuitry stops the internal MOSFET from switching and causes VCOMP to decay to GND. The device comes out of OVLO and into soft-start when VOUT1 falls below 25V (16.7V for the MAX1582Y). ...
ZXMN10A08DN8 100V N-CHANNEL ENHANCEMENT MODE MOSFET SUMMARY V
ZXMN10A08DN8 100V N-CHANNEL ENHANCEMENT MODE MOSFET SUMMARY V

... V DD =30V, I D =1.2A R G ≅6.0⍀, V GS =10V V DS =50V,V GS =5V, I D =1.2A V DS =50V,V GS =10V, I D =1.2A ...
Design of Operational Amplifier in 45nm Technology
Design of Operational Amplifier in 45nm Technology

... The simulation result of the OTA shows that the open loop gain of 66.5 dB is achieved using 45nm technology. This design gives the 74db value of CMRR and GBW of about 22 MHz. Table given below shows the various result of this OTA design. This design worked on the supply voltage of ±1 V.When we compa ...
Explain the two methods off speed control for a DC motor
Explain the two methods off speed control for a DC motor

... supply as well as load side. Power factor control is also a problem in these drives as these suffer from poor power factor. Supply voltage goes to zero in every half cycle; hence, line commutation is used. As a result, control circuit design becomes simple. Thyrsiors were the devices used earlier bu ...
AP1501
AP1501

... for the approximate junction temperature for various conditions, but be aware that there are many factors that can affect the junction temperature. When load currents higher than 2A are used, double sided or multilayer PC boards with large copper areas and/or airflow might be needed, especially for ...
4 Parallel Operation of Synchronous Generators
4 Parallel Operation of Synchronous Generators

... control is based on space phasor theory, where the electrical quantities of the machines (such as current, voltage, and flux linkage) are treated as rotating vectors. Those vectors are based on some coordinate system. The coordinate system may be firm, fixed to the stator or it may rotate within the ...
Comprehensive Design of a Three-Phase Three-Switch
Comprehensive Design of a Three-Phase Three-Switch

... However, in none of these publications a complete system design has been performed discussing current and voltage stresses and selection criterias for the passive and active components of the rectifier. Therefore, in this paper the design of the three-phase threeswitch buck-type rectifier system is ...
How to do an optimum setup for the MCA527 24.9.2013 Jörg Brutscher
How to do an optimum setup for the MCA527 24.9.2013 Jörg Brutscher

UniStar V Single Phase
UniStar V Single Phase

... The UPS units can be connected in parallel and shall share the current and load between them. In a system with several UPS units connected in parallel, there is a single MASTER unit and the remaining units are SLAVE units. The UPS units must be the same rating and the MASTER is chosen on start-up. T ...
AB22167171
AB22167171

... converter steps up the varying souce voltage to a certain constant voltage level (80–100 Vdc) and supplies the input terminals of the isolated dc/dc converter. In that case, the primary inverter within the dc/dc converter operates with a near-constant duty cycle, thus ensuring better utilization of ...
BB4103331337
BB4103331337

... [4], [5]. Such configuration allows the device to absorb or generate controllable active and reactive power. The D-STATCOM has been utilized mainly for regulation of voltage, correction of power factor and elimination of current harmonics. Such a device is employed to provide continuous voltage regu ...
BDTIC C C M - P F C
BDTIC C C M - P F C

... The ICE2PCS06/G is a 8 pin control IC for power factor correction converters. It comes in both DIP and DSO packages and is suitable for wide range line input applications from 85 to 265 VAC. The IC supports converters in boost topology and it operates in continuous conduction mode (CCM) with average ...
Journal
Journal

... Fig. 1 consists of two full-bridge circuits connected through an isolation transformer and a coupling inductor L, which may be provided partly or entirely by the transformer leakage inductance. The full bridge on the left hand side of Fig. 1 is connected to the HV dc bus and the full bridge on the r ...
Electrical noise and transients
Electrical noise and transients

... energy transients will accomplish the same thing. For example, transients which exceed the PIV (peak inverse voltage) rating of diodes are a common cause of diode failure. • Their high-frequency component (fast rise times) cause them to be capacitively coupled into adjoining conductors. If those con ...
Diodes
Diodes

... percentage change in reverse current. There is a big effect because the minority carriers that transport the reverse current are thermally generated. Now bias the diode in a forward direction to get a forward current of about 0.2 mA. Repeat the heat treatment and observe the change in current. V-I c ...
UNIT-IV-LIC
UNIT-IV-LIC

Power Factor Correction Most domestic loads (such
Power Factor Correction Most domestic loads (such

Document on creating a seismograph.
Document on creating a seismograph.

... By making the arm not move, but measure the pressure using a Piezo element, we can measure the forces involved. Since it is more or less solid state, piezo may be suitable for other mechanical construction as well, particularly a vertical mounted arm. Or a series in 2 or 3 dimensions on the same arm ...
Step 5: Solve the circuit with ATP
Step 5: Solve the circuit with ATP

... Step 3: Avoid ATP numerical instability problems ATP may have numerical instability problems if a voltage source is switched directly onto an ideal capacitor. A similar problem occurs if a current source is switched on through an ideal inductor. For these reasons, it is advisable to place a small re ...
Decoupled control of Modular Multilevel Converters using Voltage
Decoupled control of Modular Multilevel Converters using Voltage

< 1 ... 924 925 926 927 928 929 930 931 932 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025