• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Experiment 9 – Transistor i-v Characteristic and Load
Experiment 9 – Transistor i-v Characteristic and Load

DSP-BASED INSTRUMENT FOR POWER QUALITY MONITORING ON SHIPS Janusz Mindykowski Tomasz Tarasiuk
DSP-BASED INSTRUMENT FOR POWER QUALITY MONITORING ON SHIPS Janusz Mindykowski Tomasz Tarasiuk

Voltage monitoring relays CM-ESS.2
Voltage monitoring relays CM-ESS.2

FinalPresentation
FinalPresentation

MAX1472 300MHz-to-450MHz Low-Power, Crystal-Based ASK Transmitter General Description
MAX1472 300MHz-to-450MHz Low-Power, Crystal-Based ASK Transmitter General Description

... In actuality, the oscillator pulls every crystal. The crystal’s natural frequency is really below its specified frequency, but when loaded with the specified load capacitance, the crystal is pulled and oscillates at its specified frequency. This pulling is already accounted for in the specification ...
NetSure® 801 Series - Power Product Services
NetSure® 801 Series - Power Product Services

... Emerson (NYSE: EMR), based in St. Louis, is a global leader in bringing technology and engineering together to provide innovative solutions to customers through its network power, process management, industrial automation, climate technologies, and appliance and tools businesses. For more informati ...
PSS15S92F6-AG
PSS15S92F6-AG

DELCON Solid state output relays for standard and inductive loads
DELCON Solid state output relays for standard and inductive loads

... Used for all nominal voltages from 0 to 240 VAC. Pulse transformer technology means that the triac receives a continuous control current throughout the AC cycle, so Delcon can use much stronger triacs. This means that the triac does not need to be protected from fast voltage transients with an RC ci ...
Purpose: I/O Connections
Purpose: I/O Connections

... Each digital output provides an open collector circuit capable of sinking 250 ma when all are active or 350 ma individually. Each output is also capable of producing a PWM (pulse width modulation) output having 8-bit resolution at 7.8kHz. If an external power supply is used it should be connected to ...
WHY TO NOT USE AN OHMMETER TO SELECT
WHY TO NOT USE AN OHMMETER TO SELECT

... point. In this condition silicon is able to accept atoms inside its crystal frame (by a substitutive or intrusive way). The mobility allowed by high temperature makes it possible for atoms to move ahead and behind semiconductor’s surface in a random way. The point is that in the most superficial lay ...
2STL1360
2STL1360

connected photovoltaic (pv) system - IJIERT
connected photovoltaic (pv) system - IJIERT

... there are mainly two type of inverter depending on the type of the supply source and the related type of the power circuit, are classified as voltage source inverters (VSIs) and current source inverters (CSIs). And depending on the supply we can say inverter is classify in the single-phase inverters ...
Information contained herein is proprietary information of the
Information contained herein is proprietary information of the

... working at its proper voltage. If the iine voltage increases, the reset current decreases, and likewise it the line voltage decreases the reset current increases. It must be emphasized at this point that current will flow through the reset windings in only one direction because of the diode in serie ...
in Word Doc Format
in Word Doc Format

... (B) lags behind the flux by 90 degree. (C) leads the flux by 90 degree. (D) is in phase opposition to that of flux. Ans: C Q.18 The relative speed between the magnetic fields of stator and rotor under steady state operation is zero for a (A) dc machine. (B) 3 phase induction machine. (C) synchronous ...
pdf manual - Control Voltage
pdf manual - Control Voltage

... audio and control voltages (CV) by incorporating a single control to blend two signals at a time also known as a cross-fader. Two manual cross-faders and a single voltage controlled master cross-fader are provided. Use BLENDER as a main mixer or as a dynamic control for creating complex control volt ...
Technical Reference
Technical Reference

... Two-, three-, or four-wire proximity sensors contain a transistor oscillator and a snap-action amplifier. This provides exceedingly high accuracy to a set switching point, even with very slowly approaching targets. Switching characteristics are unaffected by supply voltage fluctuations within the sp ...
Distributed Generation in Power System Network to Alleviate
Distributed Generation in Power System Network to Alleviate

Comparison of Simulation Results Three Level and Five Level H
Comparison of Simulation Results Three Level and Five Level H

... The conventional voltage source inverters produce an output voltage at the poles with levels +V dc/2 or –Vdc/2 , where Vdc is the DC link voltage are known as two level inverter. To obtain a quality output voltage or a current waveform with a minimum amount of ripple content, they require high switc ...
Voltage Transducer CV 3-1500 V = 1000 V
Voltage Transducer CV 3-1500 V = 1000 V

... Low thermal drift Low response time High bandwidth High immunity to external interference ●● Low disturbance in common mode. ...
Energy saving motors
Energy saving motors

... only for one rated voltage, for example 230 V, 400 V or 690 V. They are generally designed for direct starting by using the different poles. Other volt­ages and frequencies are available as option. The pole-changing is done by › two separate windings › one winding in Dahlander connection › two se ...
Chem 133 - Problem Set #1
Chem 133 - Problem Set #1

... No, if the noise is generated by the light source, then it will also be modulated. 18. What is shielding, and what type of noise does it help reduce? Basically, shielding is wrapping wires that carry an analog signal with a grounded conductor. This will help to reduce environmental noise originatin ...
Real Time Clock - e-Gizmo Mechatronix Central
Real Time Clock - e-Gizmo Mechatronix Central

III: The Franck-Hertz Experiment
III: The Franck-Hertz Experiment

... ramping of the voltage of the power supply and the taking of the data by the computer. (It is a good idea to put the reset/ramp switch to the reset position as soon as the data sampling is completed to insure a proper zero start for the next data sampling.) You cannot collect both the current from t ...
PRESS RELEASE
PRESS RELEASE

Time Varying Voltages
Time Varying Voltages

... We have talked about the electromotive force (e.m.f.) created by chemical means in batteries. Batteries produce an e.m.f. that does not change as time passes – at least it doesn’t change up until such time as the battery wears out. There are other sources of e.m.f. that do change their amplitude as ...
< 1 ... 841 842 843 844 845 846 847 848 849 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.