
... voltage. The performance of the OpAmp is evaluated using Cadence and Matlab simulations and it satisfies the stringent requirements on the amplifier to be used in a 12-bit pipelined ADC. The open-loop DC-gain of the OpAmp is 72.35 dB with unity-frequency of 4.077 GHz. Phase-Margin (PM) of the amplif ...
MO-201 Electric Power Distribution Systems
... synchroscope, an instrument which indicates the difference in phase position and in frequency of two sources. Paralleling of generators is accomplished either manually or automatically with one incoming unit at a time. 1.2.5 DC Generation. The requirement for direct current power is limited largely ...
... synchroscope, an instrument which indicates the difference in phase position and in frequency of two sources. Paralleling of generators is accomplished either manually or automatically with one incoming unit at a time. 1.2.5 DC Generation. The requirement for direct current power is limited largely ...
62-0391 Class 3400 Meter Install Manual - E-Mon
... d. Connect the three AC main power wires (Phases A, B and C) to their respective positions as labeled on terminal block TB1 and tighten to 7 in-lb. After all conductors are connected to each of their respective terminal block positions and tightened down, verify that each terminal block screw is sec ...
... d. Connect the three AC main power wires (Phases A, B and C) to their respective positions as labeled on terminal block TB1 and tighten to 7 in-lb. After all conductors are connected to each of their respective terminal block positions and tightened down, verify that each terminal block screw is sec ...
wassenaar-arrangement-control-list-of-dual-use-goods-and
... greater than -3 dBfs (full scale). 4. 'Adjusted update rate' for DACs: a. For conventional (non-interpolating) DACs, the 'adjusted update rate' is the rate at which the digital signal is converted to an analogue signal and the output analogue values are changed by the DAC. For DACs where the interpo ...
... greater than -3 dBfs (full scale). 4. 'Adjusted update rate' for DACs: a. For conventional (non-interpolating) DACs, the 'adjusted update rate' is the rate at which the digital signal is converted to an analogue signal and the output analogue values are changed by the DAC. For DACs where the interpo ...
SKY77149 数据资料DataSheet下载
... matching circuits. The output match is realized off-chip within the module package to optimize efficiency and power performance into a 50-ohm load. This device is manufactured with Skyworks’ GaAs Heterojunction Bipolar Transistor (HBT) process that provides for all positive voltage DC supply operati ...
... matching circuits. The output match is realized off-chip within the module package to optimize efficiency and power performance into a 50-ohm load. This device is manufactured with Skyworks’ GaAs Heterojunction Bipolar Transistor (HBT) process that provides for all positive voltage DC supply operati ...
MAX14950A Single-Lane PCIe Equalizer/Redriver General Description Benefits and Features
... Soldering Temperature (reflow).......................................+260NC ...
... Soldering Temperature (reflow).......................................+260NC ...
DRTR5V0U4TS Features Mechanical Data
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
PowerCut 1300/1600
... This equipment will perform in conformity with the description thereof contained in this manual and accompanying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instructions provided. This equipment must be checked periodically. Malfunctioning or poorly ...
... This equipment will perform in conformity with the description thereof contained in this manual and accompanying labels and/or inserts when installed, operated, maintained and repaired in accordance with the instructions provided. This equipment must be checked periodically. Malfunctioning or poorly ...
part 1 general - Rockwell Automation
... The motor control center manufacturer shall check the user’s design to ensure that adequate power supplies have been specified to conform with DeviceNet requirements. b. The power supply shall provide 24Vdc for the DeviceNet system and shall be rated no less than eight amperes. c. The power supply f ...
... The motor control center manufacturer shall check the user’s design to ensure that adequate power supplies have been specified to conform with DeviceNet requirements. b. The power supply shall provide 24Vdc for the DeviceNet system and shall be rated no less than eight amperes. c. The power supply f ...
Manual - Crestron
... The following procedure will normally be performed by an authorized Crestron representative as part of the System Commissioning phase. For system wiring and basic testing as described on pages 5 and 10, it is not necessary to perform this step. Only perform this step if instructed by an authorized C ...
... The following procedure will normally be performed by an authorized Crestron representative as part of the System Commissioning phase. For system wiring and basic testing as described on pages 5 and 10, it is not necessary to perform this step. Only perform this step if instructed by an authorized C ...
SkyWalker1 and SkyWalker2 Hardware Manual
... • It is important to avoid inadvertently plugging 24v into a 12v SkyWalker2. Astrometric Instruments provides a power cable with the 24v SkyWalker2 that, it is expected, will be used with a 24v power supply. These 24v power cables, designed to accommodate a 2.1mm center pin, cannot be inadvertently ...
... • It is important to avoid inadvertently plugging 24v into a 12v SkyWalker2. Astrometric Instruments provides a power cable with the 24v SkyWalker2 that, it is expected, will be used with a 24v power supply. These 24v power cables, designed to accommodate a 2.1mm center pin, cannot be inadvertently ...
Stearns SINPAC Electronic Switches
... In Stearns SINPAC Electronic Switches, the voltage across a motor’s main winding and the voltage across its start winding are sampled and fed to a comparator. The logic circuitry is designed so that the electronic switch interrupts the start circuit current after the motor has accelerated to the spe ...
... In Stearns SINPAC Electronic Switches, the voltage across a motor’s main winding and the voltage across its start winding are sampled and fed to a comparator. The logic circuitry is designed so that the electronic switch interrupts the start circuit current after the motor has accelerated to the spe ...
Investigation and design of a wideband microwave VCO Naiyuan Zhang LiU-ITN-TEK-A--12/064--SE
... Microwave sources used to be bulky and expensive in the early era of the microwave industry. For example, vacuum tubes are in the 1940s and reflex klystrons are in the 1970s [1]. However, the evolution of microwave technology continuously demands high quality, low cost microwave oscillators. Taking ...
... Microwave sources used to be bulky and expensive in the early era of the microwave industry. For example, vacuum tubes are in the 1940s and reflex klystrons are in the 1970s [1]. However, the evolution of microwave technology continuously demands high quality, low cost microwave oscillators. Taking ...
PAM3131 Description Pin Assignments
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
MAX14508E–MAX14511E/MAX14509AE USB 2.0 Hi-Speed and Audio Switches with Negative Signal Capability General Description
... ♦ VBUS Detection for Automatic Switch Path Selection (MAX14510E/MAX14511E) ♦ Space-Saving Package: 10-Pin, 1.4mm x 1.8mm UTQFN ...
... ♦ VBUS Detection for Automatic Switch Path Selection (MAX14510E/MAX14511E) ♦ Space-Saving Package: 10-Pin, 1.4mm x 1.8mm UTQFN ...
Model 4300C - Valhalla Scientific
... Procedures involving the removal of covers or shields are for the use of service-trained personnel only. Under certain conditions, dangerous voltage may exist even with the equipment switched off. To avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal unless ...
... Procedures involving the removal of covers or shields are for the use of service-trained personnel only. Under certain conditions, dangerous voltage may exist even with the equipment switched off. To avoid dangerous electrical shock, DO NOT perform procedures involving cover or shield removal unless ...
NBC12429/D
... board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit values are applied individually under norm ...
... board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit values are applied individually under norm ...
Analogue Instruments - Crompton Instruments
... Standard dials are white matt with black printed scales and bar knife-edge pointers. Black dials with white or yellow scales and pointers are also available. Interchangeable slide-in dials are used on the E242, E243, E244 and E246 90° moving iron, moving coil and frequency meter models. General opti ...
... Standard dials are white matt with black printed scales and bar knife-edge pointers. Black dials with white or yellow scales and pointers are also available. Interchangeable slide-in dials are used on the E242, E243, E244 and E246 90° moving iron, moving coil and frequency meter models. General opti ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.