ADP3303 - Analog Devices
... The ADP3303 is a member of the ADP330x family of precision low dropout anyCAP 1 voltage regulators. The ADP3303 stands out from the conventional LDOs with a different architecture, an enhanced process, and a different package. Its patented design requires only a 0.47 µF output capacitor for stabilit ...
... The ADP3303 is a member of the ADP330x family of precision low dropout anyCAP 1 voltage regulators. The ADP3303 stands out from the conventional LDOs with a different architecture, an enhanced process, and a different package. Its patented design requires only a 0.47 µF output capacitor for stabilit ...
SDA-5000 数据资料DataSheet下载
... cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. RoHS status based on EUDirective2 ...
... cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Specified typical performance or functional operation of the device under Absolute Maximum Rating conditions is not implied. RoHS status based on EUDirective2 ...
The PLH Amplifier By Nelson Pass Introduction
... purely single-ended Class A circuit. An 80% clockwise rotation of P2 gives about a 1:1 ratio between the devices (as the pot rotates through about 10 hours of a clock, with full clockwise as 11 PM, you would set the pot to 9 PM). Linsley-Hood spent some time experimenting with his circuit using mism ...
... purely single-ended Class A circuit. An 80% clockwise rotation of P2 gives about a 1:1 ratio between the devices (as the pot rotates through about 10 hours of a clock, with full clockwise as 11 PM, you would set the pot to 9 PM). Linsley-Hood spent some time experimenting with his circuit using mism ...
Easy Calculation Yields Load Transient Response
... converter. If the loop crossover is not known, then a typical estimate would be to use one-fifth of the switching frequency. Find the intersection between the required closedloop impedance and the loop-gain crossover frequency to find the output capacitance needed to meet the voltage transient requi ...
... converter. If the loop crossover is not known, then a typical estimate would be to use one-fifth of the switching frequency. Find the intersection between the required closedloop impedance and the loop-gain crossover frequency to find the output capacitance needed to meet the voltage transient requi ...
Instructions
... The Lithium battery pack installed in the WMX101 serves as backup in the event of a power failure, when it will keep the meter operating without interruption for the duration of the outage. When battery power in is use, the WMX101 display continues to read out the rate and total, but the “P” indicat ...
... The Lithium battery pack installed in the WMX101 serves as backup in the event of a power failure, when it will keep the meter operating without interruption for the duration of the outage. When battery power in is use, the WMX101 display continues to read out the rate and total, but the “P” indicat ...
ad515a data sheet
... current-to-voltage converting amplifier. This possibility necessitates some form of input protection. Many electrometer type devices, especially CMOS designs, can require elaborate Zener protection schemes that often compromise overall performance. The AD515A requires input protection only if the so ...
... current-to-voltage converting amplifier. This possibility necessitates some form of input protection. Many electrometer type devices, especially CMOS designs, can require elaborate Zener protection schemes that often compromise overall performance. The AD515A requires input protection only if the so ...
L045076774
... As a result, the maximum power capacity and efficiency of the energy delivery are achieved, minimum perturbation to other appliances is ensured, and safe operation is warranted. However, with a fast increasing number of applications of industry electronics connected to the distribution systems today ...
... As a result, the maximum power capacity and efficiency of the energy delivery are achieved, minimum perturbation to other appliances is ensured, and safe operation is warranted. However, with a fast increasing number of applications of industry electronics connected to the distribution systems today ...
Board-Level Considerations
... with external Schmitt triggers. A Schmitt trigger is a buffer used to convert a slow or noisy signal into a clean one before passing it to the FPGA fabric. This is a simple, low-cost solution for a user working with low-slew-rate signals. In the case of output slew rate, a high number of application ...
... with external Schmitt triggers. A Schmitt trigger is a buffer used to convert a slow or noisy signal into a clean one before passing it to the FPGA fabric. This is a simple, low-cost solution for a user working with low-slew-rate signals. In the case of output slew rate, a high number of application ...
Thermal Mass Flow Controllers
... Flow in the FMA 3200/3400 Series is controlled by a proportional solenoid valve with active servo electronics. The flow measurement signal is analyzed by micro-processor controlled electronics and compared to a setpoint. Adjustments are then made to the valve in order to achieve the required flow ra ...
... Flow in the FMA 3200/3400 Series is controlled by a proportional solenoid valve with active servo electronics. The flow measurement signal is analyzed by micro-processor controlled electronics and compared to a setpoint. Adjustments are then made to the valve in order to achieve the required flow ra ...
High Performance Charge Pump Converter with Integrated CMOS
... higher output capacitance. The result means that the output of the charge pump depends more on the pump capacitance and corresponds to the equation (3). The output voltage of the charge pump regulator, which has the feedback control circuit, is studied with the variation of the number of pump stages ...
... higher output capacitance. The result means that the output of the charge pump depends more on the pump capacitance and corresponds to the equation (3). The output voltage of the charge pump regulator, which has the feedback control circuit, is studied with the variation of the number of pump stages ...
Exp. No #1 Date: DIODE CLIPPERS AND CLAMPERS OBJECTIVE The purpose
... EEE392 Measurements and Analog Circuits Lab ...
... EEE392 Measurements and Analog Circuits Lab ...
Evaluates: MAX5943A/B/C/D/E MAX5943A Evaluation Kit General Description Features
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. ...
... Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim reserves the right to change the circuitry and specifications without notice at any time. ...
User`s Manual Model 701920 Differential Probe for DL Series
... Make sure to comply with the safety precautions mentioned hereafter when handling the probe. YOKOGAWA ELECTRIC Co. assumes no responsibility for any consequences resulting from failure to comply with these safety precautions. Also, read the User's Manual of the measuring instrument thoroughly so tha ...
... Make sure to comply with the safety precautions mentioned hereafter when handling the probe. YOKOGAWA ELECTRIC Co. assumes no responsibility for any consequences resulting from failure to comply with these safety precautions. Also, read the User's Manual of the measuring instrument thoroughly so tha ...
FDS4685 40V P-Channel PowerTrench MOSFET
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
VME600(8) -1- (5,50)(-5,6)(12,12)(-12,2)(3.3,26) (
... P/N 94028-3 Behlman’s VME600 COTS power supply is a dual redundant rugged, low cost, highly reliable, switch mode unit built for high-end industrial and military applications to power work stations and VME card racks. The VME600 can accept a wide range of AC inputs and can supply a variety of DC out ...
... P/N 94028-3 Behlman’s VME600 COTS power supply is a dual redundant rugged, low cost, highly reliable, switch mode unit built for high-end industrial and military applications to power work stations and VME card racks. The VME600 can accept a wide range of AC inputs and can supply a variety of DC out ...
Project Three – BJT Amplifier
... In Figure 1.1, we can see that there are two junctions in the BJT. On a diode, the p-type substrate is connected to the anode (+) and the n-type is connected to the cathode (-). When there is a positive voltage across the diode (the voltage on the anode is greater than the voltage on the cathode) th ...
... In Figure 1.1, we can see that there are two junctions in the BJT. On a diode, the p-type substrate is connected to the anode (+) and the n-type is connected to the cathode (-). When there is a positive voltage across the diode (the voltage on the anode is greater than the voltage on the cathode) th ...
The Zen Variations - Part 5
... and vice versa. While this still constitutes one gain stage, the two devices give more gain and ...
... and vice versa. While this still constitutes one gain stage, the two devices give more gain and ...
An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery
... measurement test on a vehicle battery. However, spectrums are very depending to the values of components used in the modelization of the Randles circuit. Measurements were carried out at different nominal voltages (12.7V, 10V, 8V and 5V) with two imposed currents (0.6 A and 4A). The choice ...
... measurement test on a vehicle battery. However, spectrums are very depending to the values of components used in the modelization of the Randles circuit. Measurements were carried out at different nominal voltages (12.7V, 10V, 8V and 5V) with two imposed currents (0.6 A and 4A). The choice ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.