MAX7060 280MHz to 450MHz Programmable ASK/FSK Transmitter EVALUATION KIT AVAILABLE
... coded for FSK can be maintained while still satisfying regulatory emission-bandwidth standards. The full set of configuration functions are handled by an on-chip serial peripheral interface (SPI). There is also a manual mode where a limited number of settings can be made directly through selected pi ...
... coded for FSK can be maintained while still satisfying regulatory emission-bandwidth standards. The full set of configuration functions are handled by an on-chip serial peripheral interface (SPI). There is also a manual mode where a limited number of settings can be made directly through selected pi ...
Model Number Structure - OMRON Industrial Automation
... When the power is turned ON and the set time has elapsed, an output is produced. (Power turns ON when power terminals 1 and 24 are shorted or when terminals 13 and 15 are shorted when using a 12/24 V DC-operated model with a 12 V DC power supply.) When connecting an external resistor to the Timer, c ...
... When the power is turned ON and the set time has elapsed, an output is produced. (Power turns ON when power terminals 1 and 24 are shorted or when terminals 13 and 15 are shorted when using a 12/24 V DC-operated model with a 12 V DC power supply.) When connecting an external resistor to the Timer, c ...
AS3729
... rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its General Terms of Trade. ams AG ...
... rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its General Terms of Trade. ams AG ...
da ta sheet f112 - flow ra te indic a tor / to talizer flow rate indicator
... and dust applications with an operational temperature range of -30°C to +70°C (-22°F to +158°F). Besides the I.S. power supply for the pulse output, it is allowed to connect up to three I.S. power supplies in IIB applications or one in IIC applications. Full functionality of the F112 remains availab ...
... and dust applications with an operational temperature range of -30°C to +70°C (-22°F to +158°F). Besides the I.S. power supply for the pulse output, it is allowed to connect up to three I.S. power supplies in IIB applications or one in IIC applications. Full functionality of the F112 remains availab ...
AD8381 数据手册DataSheet 下载
... in data projectors. It comprises six channels of precision 10-bit digital-to-analog converters loaded from a single, high speed, 10-bit-wide input. Precision current feedback amplifiers, providing well-damped pulse response and rapid voltage settling into large capacitive loads, buffer the six outpu ...
... in data projectors. It comprises six channels of precision 10-bit digital-to-analog converters loaded from a single, high speed, 10-bit-wide input. Precision current feedback amplifiers, providing well-damped pulse response and rapid voltage settling into large capacitive loads, buffer the six outpu ...
7.1. General Features - Page de test
... 5. AUDIO AMPLIFIER STAGE WITH TDA7299 The TDA7299 is an audio class-AB amplifier assembled in SO package specially designed for sound cards application. By utilizing two TDA7299, chassis operates as a stereo TV set. TDA7299 has standby feature for low stand-by power consumption by using pin #3. It c ...
... 5. AUDIO AMPLIFIER STAGE WITH TDA7299 The TDA7299 is an audio class-AB amplifier assembled in SO package specially designed for sound cards application. By utilizing two TDA7299, chassis operates as a stereo TV set. TDA7299 has standby feature for low stand-by power consumption by using pin #3. It c ...
D6000 MesCom Shortform Rev2
... Outputs are open collector outputs to ground with back EMF protection for use with small inductive loads (eg relays) with a maximum 100mA load. Internal monitoring of temperature, battery voltage, supply voltage, and radio module state is also performed. The board temperature sensor has an accuracy ...
... Outputs are open collector outputs to ground with back EMF protection for use with small inductive loads (eg relays) with a maximum 100mA load. Internal monitoring of temperature, battery voltage, supply voltage, and radio module state is also performed. The board temperature sensor has an accuracy ...
S4000
... input DC voltage to the strobe terminals. When it is desired to operate the strobe with all of the audible signals, only a set of jumpers shall be required. The notification appliance shall be a Wheelock Series AMT audible/visual appliance or equivalent. Notification appliance shall be electronic an ...
... input DC voltage to the strobe terminals. When it is desired to operate the strobe with all of the audible signals, only a set of jumpers shall be required. The notification appliance shall be a Wheelock Series AMT audible/visual appliance or equivalent. Notification appliance shall be electronic an ...
DS2731 Cache-Memory Battery-Backup Management IC General Description Features
... constant-current (CC) charge, and constant-voltage (CV) charge. Precondition mode charges at a reduced rate for a severely depleted cell. CC mode charge rate is user selectable from 0.5A to 1.5A. In CV mode, charge is terminated when the charging current falls below 5% of CC mode charge rate. The CV ...
... constant-current (CC) charge, and constant-voltage (CV) charge. Precondition mode charges at a reduced rate for a severely depleted cell. CC mode charge rate is user selectable from 0.5A to 1.5A. In CV mode, charge is terminated when the charging current falls below 5% of CC mode charge rate. The CV ...
4.5V to 18V Input Voltage, 3A/2A/2A Output Current Triple
... 3A/2A/2A output currents. A wide 4.5V to 18V input supply voltage range encompasses the most intermediate bus voltages operating off 5V, 9V, 12V or 15V power bus. The converter, with constant frequency peak current mode, is designed to simplify its application while giving designers options to optim ...
... 3A/2A/2A output currents. A wide 4.5V to 18V input supply voltage range encompasses the most intermediate bus voltages operating off 5V, 9V, 12V or 15V power bus. The converter, with constant frequency peak current mode, is designed to simplify its application while giving designers options to optim ...
CC2592 2.4-GHz Range Extender
... Driving the CC2592 device too far into saturation might result in spurious emissions and harmonics above regulatory limits. This caution should especially be considered for systems targeting a wide operating temperature range, where a combination of low temperature, low supply voltage, and a transce ...
... Driving the CC2592 device too far into saturation might result in spurious emissions and harmonics above regulatory limits. This caution should especially be considered for systems targeting a wide operating temperature range, where a combination of low temperature, low supply voltage, and a transce ...
HMMC-3122 DC-12 GHz Packaged High Efficiency Divide-by
... The device is designed to operate when driven with either a single-ended or differential sinusoidal input signal over a 200 MHz to 12 GHz bandwidth. Below 200 MHz the prescaler input is “slew-rate” limited, requiring fast rising and falling edge speeds to properly divide. The device will operate at ...
... The device is designed to operate when driven with either a single-ended or differential sinusoidal input signal over a 200 MHz to 12 GHz bandwidth. Below 200 MHz the prescaler input is “slew-rate” limited, requiring fast rising and falling edge speeds to properly divide. The device will operate at ...
TPS75601 数据资料 dataSheet 下载
... device will be in shutdown or sleep mode. When EN goes to a high voltage level (> 2 V), the device will be enabled. Feedback (FB) FB is an input terminal used for the adjustable-output option and must be connected to the output terminal either directly, in order to generate the minimum output voltag ...
... device will be in shutdown or sleep mode. When EN goes to a high voltage level (> 2 V), the device will be enabled. Feedback (FB) FB is an input terminal used for the adjustable-output option and must be connected to the output terminal either directly, in order to generate the minimum output voltag ...
Effectively Using Pressure, Load, and Torque Sensors with Today`s
... Pressure is the force per unit area exerted by a fluid or gas. The recognized International System of Units (SI) for pressure measurement is the Pascal (Pa); however, pounds per square inch (psi), inches of water (in-H2O), Newtons per millimeter squared (N/mm2) and Bar are also common. The most crit ...
... Pressure is the force per unit area exerted by a fluid or gas. The recognized International System of Units (SI) for pressure measurement is the Pascal (Pa); however, pounds per square inch (psi), inches of water (in-H2O), Newtons per millimeter squared (N/mm2) and Bar are also common. The most crit ...
Evaluates: MAX5138/MAX5139 MAX5138 Evaluation Kit General Description Features
... internal 2.440V reference. To use AVDD as the reference, place the shunt on jumper JU9 in the 2-3 position. For off-board external references, connect a user-supplied reference voltage to REFIN and remove the shunt on jumper JU9. Type in the reference voltage value in the Set Vref edit box and press ...
... internal 2.440V reference. To use AVDD as the reference, place the shunt on jumper JU9 in the 2-3 position. For off-board external references, connect a user-supplied reference voltage to REFIN and remove the shunt on jumper JU9. Type in the reference voltage value in the Set Vref edit box and press ...
KL3518001806
... multilevel inverters topologies, control techniques, and applications. However, there are few studies that actually discuss or evaluate the performance of induction motor drives associated with three-phase multilevel inverter. This paper presents a comparison study of symmetrical and asymmetrical fo ...
... multilevel inverters topologies, control techniques, and applications. However, there are few studies that actually discuss or evaluate the performance of induction motor drives associated with three-phase multilevel inverter. This paper presents a comparison study of symmetrical and asymmetrical fo ...
final_report - An-Najah National University
... In power engineering, the power flow study, also known as load-flow study, is an important tool involving numerical analysis applied to a power system. A power flow study usually uses simplified notation such as a one-line diagram and perunit system, and focuses on various forms of AC power (i.e.: v ...
... In power engineering, the power flow study, also known as load-flow study, is an important tool involving numerical analysis applied to a power system. A power flow study usually uses simplified notation such as a one-line diagram and perunit system, and focuses on various forms of AC power (i.e.: v ...
EVC4000 Instruction Manual - World Precision Instruments
... The purpose of the procedure below, in a real experiment, is to prevent varying transmural current (during voltage clamp) from causing an error in the measured transmural voltage. It allows the user to experimentally determine the resistance of bathing fluid normally between the voltage electrodes a ...
... The purpose of the procedure below, in a real experiment, is to prevent varying transmural current (during voltage clamp) from causing an error in the measured transmural voltage. It allows the user to experimentally determine the resistance of bathing fluid normally between the voltage electrodes a ...
AFR 10_Manual_English-5
... 2,5 mm2 cross-section. The connection wiring schema is shown below. Terminal b or n or dn of the load must be grounded preferably to the terminal of the transformer. Before commission make sure that this grounding is present and is not duplicate (at the transformer sec. output and at the protection ...
... 2,5 mm2 cross-section. The connection wiring schema is shown below. Terminal b or n or dn of the load must be grounded preferably to the terminal of the transformer. Before commission make sure that this grounding is present and is not duplicate (at the transformer sec. output and at the protection ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.