LF to 2.5 GHz TruPwr™ Detector AD8361 Data Sheet
... 2.5 GHz. It is very easy to apply. It requires a single supply only between 2.7 V and 5.5 V, a power supply decoupling capacitor, and an input coupling capacitor in most applications. The output is a linear-responding dc voltage with a conversion gain of 7.5 V/V rms. An external filter capacitor can ...
... 2.5 GHz. It is very easy to apply. It requires a single supply only between 2.7 V and 5.5 V, a power supply decoupling capacitor, and an input coupling capacitor in most applications. The output is a linear-responding dc voltage with a conversion gain of 7.5 V/V rms. An external filter capacitor can ...
CAT4016 - LED Driver, 16-Channel, Constant Current
... ON Semiconductor owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of ON Semiconductor’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. ON Semiconductor reserves the right to make changes ...
... ON Semiconductor owns the rights to a number of patents, trademarks, copyrights, trade secrets, and other intellectual property. A listing of ON Semiconductor’s product/patent coverage may be accessed at www.onsemi.com/site/pdf/Patent−Marking.pdf. ON Semiconductor reserves the right to make changes ...
Technical Data
... is the most up to date and respected line of surge protection devices in the industry due to its exceptional technology and performance. With over two decades of experience in the surge suppression industry and extensive R & D initiatives, CutlerHammer is considered a world leader in surge protectiv ...
... is the most up to date and respected line of surge protection devices in the industry due to its exceptional technology and performance. With over two decades of experience in the surge suppression industry and extensive R & D initiatives, CutlerHammer is considered a world leader in surge protectiv ...
Universal Audio UA 6176
... style) output stage. (Later versions replaced the Class A output stage with a push-pull Class-AB output stage, and eventually replaced the transformer input with a differential op-amp circuit.) The limiting / compression section in the 6176 captures that highly recognizable blackface 1176LN sound. M ...
... style) output stage. (Later versions replaced the Class A output stage with a push-pull Class-AB output stage, and eventually replaced the transformer input with a differential op-amp circuit.) The limiting / compression section in the 6176 captures that highly recognizable blackface 1176LN sound. M ...
DIGIPLAN 1054 STEPPER MOTOR DRIVE INSTRUCTION
... At this point it is appropriate to define some of the terms used in connection with stepper motors and their operation. Some of the terms have been used already and others will be introduced in the next section. The list has been confined to those terms which are necessary for a basic understanding ...
... At this point it is appropriate to define some of the terms used in connection with stepper motors and their operation. Some of the terms have been used already and others will be introduced in the next section. The list has been confined to those terms which are necessary for a basic understanding ...
TS14002 - Semtech
... BSC: Basic Dimension. Theoretically exact values shown without tolerances. REF: Reference Dimension, usually without tolerance, for information only. ...
... BSC: Basic Dimension. Theoretically exact values shown without tolerances. REF: Reference Dimension, usually without tolerance, for information only. ...
Low power variable gain amplifier
... signals and the current provided by the current steering stage 106. The current steering stage, for example, implements gain control by directing part of the input current Iin, to the output and the remaining part of the current, indicated as If, to the feedback circuit 104. The current steering sta ...
... signals and the current provided by the current steering stage 106. The current steering stage, for example, implements gain control by directing part of the input current Iin, to the output and the remaining part of the current, indicated as If, to the feedback circuit 104. The current steering sta ...
Model 6176 Channel Strip
... style) output stage. (Later versions replaced the Class A output stage with a push-pull Class-AB output stage, and eventually replaced the transformer input with a differential op-amp circuit.) The limiting / compression section in the 6176 captures that highly recognizable blackface 1176LN sound. M ...
... style) output stage. (Later versions replaced the Class A output stage with a push-pull Class-AB output stage, and eventually replaced the transformer input with a differential op-amp circuit.) The limiting / compression section in the 6176 captures that highly recognizable blackface 1176LN sound. M ...
Advantages of IC-Based Hot-Swap Circuit
... smaller and less expensive circuit connectors, and generally smaller components in the power path. The simplest current-limiting component is the fuse, which can be used by itself or in combination with other protection elements. Because fuses are effective against overcurrent, they are either requi ...
... smaller and less expensive circuit connectors, and generally smaller components in the power path. The simplest current-limiting component is the fuse, which can be used by itself or in combination with other protection elements. Because fuses are effective against overcurrent, they are either requi ...
Evaluation Board User Guide UG-136
... circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentati ...
... circuitry, damage may occur on devices subjected to high energy ESD. Therefore, proper ESD precautions should be taken to avoid performance degradation or loss of functionality. Legal Terms and Conditions By using the evaluation board discussed herein (together with any tools, components documentati ...
G49045358
... common neutral conductor. Fig. 6 shows the stardelta transformer connection for compensating the neutral current. It consists of a star-delta transformer, a diode rectifier, and a half-bridge PWM inverter. The active power filter generates compensating currents that result in effective cancellation ...
... common neutral conductor. Fig. 6 shows the stardelta transformer connection for compensating the neutral current. It consists of a star-delta transformer, a diode rectifier, and a half-bridge PWM inverter. The active power filter generates compensating currents that result in effective cancellation ...
MAX17020 Dual Quick-PWM Step-Down Controller with Low-Power LDO, RTC Regulator General Description
... forces the controller to maintain switching frequencies greater than 20kHz at light loads. An internal 100mA linear regulator can be used to either generate the 5V bias needed for power-up or other lower power “always-on” suspend supplies. An independent bypass input allows automatic bypassing of th ...
... forces the controller to maintain switching frequencies greater than 20kHz at light loads. An internal 100mA linear regulator can be used to either generate the 5V bias needed for power-up or other lower power “always-on” suspend supplies. An independent bypass input allows automatic bypassing of th ...
XARTU/1™ Manual - Eagle Research Corporation
... programmable time scheduled interrupt capability One ambient temperature input; one supply voltage input Four pulse inputs, software programmable for Form A or C; high or low speed. Each counter is a six-digit (0-999999) hardware counter with programmable interrupt support. Can be used for simple pu ...
... programmable time scheduled interrupt capability One ambient temperature input; one supply voltage input Four pulse inputs, software programmable for Form A or C; high or low speed. Each counter is a six-digit (0-999999) hardware counter with programmable interrupt support. Can be used for simple pu ...
ancillary service details: voltage control
... Taken together, these two factors result in a dynamic reactive-power requirement. The loss of a generator or a major transmission line can have the compounding effect of reducing the reactive supply and, at the same time, reconfiguring flows such that the system is consuming additional reactive powe ...
... Taken together, these two factors result in a dynamic reactive-power requirement. The loss of a generator or a major transmission line can have the compounding effect of reducing the reactive supply and, at the same time, reconfiguring flows such that the system is consuming additional reactive powe ...
NIM article 2009 - MC-PAD
... which the signal starts to rise reflects the radiation-induced increase of the space charge. For the samples irradiated to fluences above 1015 neq/cm2, no saturation of the signal with increasing bias is visible. It is remarkable that even after a fluence of 2:8 1015 neq =cm2 a charge of more than 10 ...
... which the signal starts to rise reflects the radiation-induced increase of the space charge. For the samples irradiated to fluences above 1015 neq/cm2, no saturation of the signal with increasing bias is visible. It is remarkable that even after a fluence of 2:8 1015 neq =cm2 a charge of more than 10 ...
AD7843
... The bits are clocked out on the falling edge of the DCLK input. This output is high impedance when CS is high. BUSY Output. Logic Output. This output is high impedance when CS is high. Data In. Logic input. Data to be written to the AD7843 control register is provided on this input and is clocked in ...
... The bits are clocked out on the falling edge of the DCLK input. This output is high impedance when CS is high. BUSY Output. Logic Output. This output is high impedance when CS is high. Data In. Logic input. Data to be written to the AD7843 control register is provided on this input and is clocked in ...
Considerations for Applying Tuned Capacitor Banks
... In recent years, the process of disinfecting fresh water has shifted from chlorination to ozone treatment. The ozone generator requires a dc source for producing the high frequency ac necessary to ionize oxygen and produce ozone. The water treatment plant that is the subject of this paper operated t ...
... In recent years, the process of disinfecting fresh water has shifted from chlorination to ozone treatment. The ozone generator requires a dc source for producing the high frequency ac necessary to ionize oxygen and produce ozone. The water treatment plant that is the subject of this paper operated t ...
Pulse-width modulation
Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.