• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
DYNAMIC VOLTAGE FREQUENCY SCALING (DVFS) FOR
DYNAMIC VOLTAGE FREQUENCY SCALING (DVFS) FOR

... paper to carry out the appropriate voltage via the frequency. The operation of this control loop is depending on the difference between the clock frequency fclk from VCO and fdes from the operating system predictor, where the output of the VCO, fclk, clocks a counter which is reset at 1MHz intervals ...
Ch 3 Measurement
Ch 3 Measurement

The PTO-generator - Publikationsdatenbank der TU Wien
The PTO-generator - Publikationsdatenbank der TU Wien

... switching relays on the other side. Figure 1 shows the whole PTO-generator device in a draft as well as a picture of the power pack itself and mounted on a tractor. ...
Triangle to Sine Conversion (Nonlinear Function Fitting)
Triangle to Sine Conversion (Nonlinear Function Fitting)

... by applying a triangular waveform. This is illustrated below; the triangular wave is applied as the base signal of the differential pair, with the peak values ±Vm selected appropriately . If the periodic function so formed is expanded in a Fourier series that series contains only sine terms since th ...
IEEE 519 Tables Regarding Voltage and Harmonic Distortion Limits
IEEE 519 Tables Regarding Voltage and Harmonic Distortion Limits

... V ≤ 1.0 kV 1 kV < V ≤ 69 kV 69 kV < V ≤ 161 kV 161 kV < V ...
Exercise A
Exercise A

CHAPTER 1
CHAPTER 1

... The commands to the arm is from radio frequency transmitter (TX02), which transmits the signal processed for corresponding switching pulse at 35MHz frequency range. It is received at radio frequency receiver (RX02), and this is processed and given to microcontroller to drive the motors. TEMPERATURE ...
(minimum-delay or zero
(minimum-delay or zero

... • A variety of signals - sinewaves, pulses, pseudo-random signals - can be used for seismometer calibration. However, it is risky to rely on the precision of a waveform generator. Preferably, the input signal should be recorded together with the output signal. • The transfer function is defined as t ...
MAX8500–MAX8504 PWM Buck Converters with Bypass FET for N-CDMA/W-CDMA Handsets General Description
MAX8500–MAX8504 PWM Buck Converters with Bypass FET for N-CDMA/W-CDMA Handsets General Description

... allows automatic PWM control at medium and heavy loads and skip mode at light loads to improve efficiency and reduce quiescent current to 280µA. Operating in normal mode also allows the MAX8500–MAX8504 to pulse skip when the peak inductor current drops below 148mA, corresponding to a load current of ...
Unit BS113 Electrical and Electronic Technology
Unit BS113 Electrical and Electronic Technology

... 2. There is no water in the drum (A switch or logic 1 indicates the PRESENCE of water) 3. The machine on-off switch is at OFF (logic 0 or switch) Use (a) switches and (b) AND, OR and NOT gates. In Part (a), you must say whether the switches need to be normally-open or normally-closed. What electrica ...
get protected
get protected

QED PROD DIRECT (DEC) 1A (Page 1)
QED PROD DIRECT (DEC) 1A (Page 1)

... MA18 HEADPHONE VOLUME CONTROL Features ...
sofTap Dimmer, 700W (Incandescent, Halogen, CFL, LED, ELV
sofTap Dimmer, 700W (Incandescent, Halogen, CFL, LED, ELV

... ADTP703TUM4 ...
Slide 1
Slide 1

... deliver to a storage capacitor. • Substantial power output demonstrated with average power output being 2 mW per shoe. • Further optimization possible to obtain higher powers. • Steps can be detected for zero velocity updating for more accurate IMU. ...
Golden Road Electronic Co., Ltd. Distributed By Rohm
Golden Road Electronic Co., Ltd. Distributed By Rohm

... Current feedback input pin detect the lamp current through a half rectifier circuit and a resistor, output compared with VREF (1.25V)which it is using an internal error amplifier to adjusting the PWM duty. In this loop, please must keep Is more than 0.4V, or the SRT will turn to LOW, SCP start to wo ...
Active Harmonic Filtering Using Current Controlled Grid
Active Harmonic Filtering Using Current Controlled Grid

Power Systems Analysis
Power Systems Analysis

... Proper coordination with the variable-frequency drive manufacturer is needed to obtain accurate harmonic characteristics for the specific drives ...
company name - Schneider Electric
company name - Schneider Electric

... Required reactive power calculations greatly depend on the purpose (objective) of the compensation system. Utility bills may provide total reactive requirements and information on the target power factor levels required. Better yet is to have actual load magnitude measurements (either total for the ...
MAX8523 High-Speed, Dual-Phase Gate Driver for Multiphase, Step-Down Converters General Description
MAX8523 High-Speed, Dual-Phase Gate Driver for Multiphase, Step-Down Converters General Description

... BST_ to PGND_ ......................................................-0.3V to +26V LX_ to PGND_............................................................-1V to +14V DH_ to PGND_..........................................-0.3V to (BST_ + 0.3V) DH_ to LX_............................................... ...
E E 2440 Circuits I
E E 2440 Circuits I

... • Electromechanical Energy Conversion • Power Electronics – High frequency switching converters – High efficiency, high power density ...
Presentation Title Here
Presentation Title Here

Slide 1 - UCF EECS
Slide 1 - UCF EECS

... The RPM will be displayed on the touch screen to allow driver to know when to shift gears because electric vehicles don’t have engine noise to know when to shift. Current used to measure the +/- 500 amps of motor and battery current is the F.W. Bell RSS-200A Hall Effect sensor. The sensor has a line ...
The other night, a full moon emerged over the flat, wet Louisiana
The other night, a full moon emerged over the flat, wet Louisiana

... capacitance. Such resistors are available as long as the frequency is not too high (they are called non-inductive resistors, as inductance is the main nonideality for a resistor). It is also assumed—perhaps wrongly!—that the signal generator will not vary its output with frequency into this load. Th ...
Control your Power - AEG Power Solutions
Control your Power - AEG Power Solutions

... Available as one, two and three-phase units, the new Thyro-A series supports voltages of 24V to 600V offering a unique product range of 2A up to 1,500A. It has a new and revolutionary connection concept, FlexConnect, for flexible mains and load connections. A world first is the new power controller’ ...
Li-Ion battery charger design for laptop computer applications
Li-Ion battery charger design for laptop computer applications

... I2 control for the purpose of brevity. A block diagram of I2 control for a Buck regulator is shown in Fig. 3. A constantfrequency clock signal initiates the on time of the high side switch. There are two feedback loops. The feedback signal ISENSE is the voltage across the sense resistor and is propo ...
< 1 ... 1113 1114 1115 1116 1117 1118 1119 1120 1121 ... 1202 >

Pulse-width modulation



Pulse-width modulation (PWM), or pulse-duration modulation (PDM), is a modulation technique used to encode a message into a pulsing signal. Although this modulation technique can be used to encode information for transmission, its main use is to allow the control of the power supplied to electrical devices, especially to inertial loads such as motors. In addition, PWM is one of the two principal algorithms used in photovoltaic solar battery chargers, the other being MPPT.The average value of voltage (and current) fed to the load is controlled by turning the switch between supply and load on and off at a fast rate. The longer the switch is on compared to the off periods, the higher the total power supplied to the load.The PWM switching frequency has to be much higher than what would affect the load (the device that uses the power), which is to say that the resultant waveform perceived by the load must be as smooth as possible. Typically switching has to be done several times a minute in an electric stove, 120 Hz in a lamp dimmer, from few kilohertz (kHz) to tens of kHz for a motor drive and well into the tens or hundreds of kHz in audio amplifiers and computer power supplies.The term duty cycle describes the proportion of 'on' time to the regular interval or 'period' of time; a low duty cycle corresponds to low power, because the power is off for most of the time. Duty cycle is expressed in percent, 100% being fully on.The main advantage of PWM is that power loss in the switching devices is very low. When a switch is off there is practically no current, and when it is on and power is being transferred to the load, there is almost no voltage drop across the switch. Power loss, being the product of voltage and current, is thus in both cases close to zero. PWM also works well with digital controls, which, because of their on/off nature, can easily set the needed duty cycle.PWM has also been used in certain communication systems where its duty cycle has been used to convey information over a communications channel.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report