Instruction Manual
... This company makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular purpose. Further, this company reserves the right to revise this publication and to make chan ...
... This company makes no representations or warranties, either expressed or implied, with respect to the contents hereof and specifically disclaims any warranties, merchantability or fitness for any particular purpose. Further, this company reserves the right to revise this publication and to make chan ...
IOSR Journal of Electrical And Electronics Engineering (IOSRJEEE)
... equations have been applied in developing load flow algorithms, during last four decades. The most desirable features to compare the different load flow methods can be the memory storage requirement, speed of solution, accuracy of the solution and the reliability of convergence depending upon a give ...
... equations have been applied in developing load flow algorithms, during last four decades. The most desirable features to compare the different load flow methods can be the memory storage requirement, speed of solution, accuracy of the solution and the reliability of convergence depending upon a give ...
IOSR Journal of Electronics and Communication Engineering (IOSR-JECE)
... A linear voltage regulator utilizes a tunable resistive circuit,applying resistive voltage division to generate an output dc voltage from a higher dc voltage. The on-chip area of a linear regulator can be quite small, but the power efficiency is intrinsically low due to the resistive voltage divider ...
... A linear voltage regulator utilizes a tunable resistive circuit,applying resistive voltage division to generate an output dc voltage from a higher dc voltage. The on-chip area of a linear regulator can be quite small, but the power efficiency is intrinsically low due to the resistive voltage divider ...
SPS2 Circuit Breaker (15kV-245kV)
... chamber is arranged in the insulator, which can be either porcelain or of a composite material, and is at high potential with the voltage level determining the length of the insulators for the interrupter chamber and the insulator column. For higher voltage levels, several interrupter chambers serie ...
... chamber is arranged in the insulator, which can be either porcelain or of a composite material, and is at high potential with the voltage level determining the length of the insulators for the interrupter chamber and the insulator column. For higher voltage levels, several interrupter chambers serie ...
2008. Lecture 11 (361-1
... one) at its input into the high and low voltages (binary one and binary zero), respectively, at its output. Note also that the input impedance of a NOT gate is very high and its output impedance is very low. In general, its transfer characteristic is nonlinear; however, there is a linear transition ...
... one) at its input into the high and low voltages (binary one and binary zero), respectively, at its output. Note also that the input impedance of a NOT gate is very high and its output impedance is very low. In general, its transfer characteristic is nonlinear; however, there is a linear transition ...
Optocouplers in Switching Power Supplies
... Isolation test voltage for routine tests is at factor 1.875 higher than the specified VIOWM/VIORM (peak). A partial discharge test is a different test method to the normal isolation voltage test. This method is more sensitive and will not damage the isolation behavior of the optocoupler like other t ...
... Isolation test voltage for routine tests is at factor 1.875 higher than the specified VIOWM/VIORM (peak). A partial discharge test is a different test method to the normal isolation voltage test. This method is more sensitive and will not damage the isolation behavior of the optocoupler like other t ...
Multilayer Technology Varistor Plus Term Sym bol
... Toll Free: (888) SEI-SEI-SEI • www.seielect.com • email: [email protected] • ISO 9002 / QS 9000 Registered ...
... Toll Free: (888) SEI-SEI-SEI • www.seielect.com • email: [email protected] • ISO 9002 / QS 9000 Registered ...
The RS-485 Unit Load and Maximum Number of
... The number of Unit Loads (nUL) presented by any proposed connection to the RS-485 bus is then determined as the ratio of its measured input current and that of one Unit Load. Because one Unit Load’s current is a function of voltage, the input current must be measured and the ratio determined through ...
... The number of Unit Loads (nUL) presented by any proposed connection to the RS-485 bus is then determined as the ratio of its measured input current and that of one Unit Load. Because one Unit Load’s current is a function of voltage, the input current must be measured and the ratio determined through ...
Electromagnetic Pulse Generator
... Any design will require constraints. For the sake of a research project for school, I have limited the effective range of my pulse generator to two feet to ensure I will not destroy any lab equipment in the process. Another limitation was that I have chosen a maximum voltage of 1000 volts for safety ...
... Any design will require constraints. For the sake of a research project for school, I have limited the effective range of my pulse generator to two feet to ensure I will not destroy any lab equipment in the process. Another limitation was that I have chosen a maximum voltage of 1000 volts for safety ...
Grid connected renewable energy system using unified power
... 1) Two inverters - one connected across the load which acts as a shunt APF and other connected in series with the line as that of series APF. 2) Shunt coupling inductor Lsh is used to interface the shunt inverter to the network. It also helps in smoothing the current wave shape. Sometimes an isolati ...
... 1) Two inverters - one connected across the load which acts as a shunt APF and other connected in series with the line as that of series APF. 2) Shunt coupling inductor Lsh is used to interface the shunt inverter to the network. It also helps in smoothing the current wave shape. Sometimes an isolati ...
Types of Electrical Overstress Protection
... Figure 3. Bidirectional and Unidirectional Voltage Clamping Protection Devices with the Range of Safe and Unsafe Conditions for the Circuit Being Protected ...
... Figure 3. Bidirectional and Unidirectional Voltage Clamping Protection Devices with the Range of Safe and Unsafe Conditions for the Circuit Being Protected ...
Irradiation tests of voltage limiters
... will be higher than 8 V in worst cases. In an event of sudden current drop supply voltage at modules could exceed the maximum allowed for ASICs because the reaction time of power supply control is too long (few ms). The sudden current drops could be caused by e.g. changing front end biasing DACs fro ...
... will be higher than 8 V in worst cases. In an event of sudden current drop supply voltage at modules could exceed the maximum allowed for ASICs because the reaction time of power supply control is too long (few ms). The sudden current drops could be caused by e.g. changing front end biasing DACs fro ...
XIV. Glossary of Terms
... In a pressure transducer or impulse hammer, this refers to the unwanted output signal from the sensor in response to vibration in the sensitive axis of the sensor. This parameter is specified in terms of psi/g for pressure sensors and Lbs/g for impulse hammers. Certain Dytran sensors such as the Ser ...
... In a pressure transducer or impulse hammer, this refers to the unwanted output signal from the sensor in response to vibration in the sensitive axis of the sensor. This parameter is specified in terms of psi/g for pressure sensors and Lbs/g for impulse hammers. Certain Dytran sensors such as the Ser ...
Rigorous dispersive analysis of skin effects on a printed microstrip
... representing the equivalent wave impedance at the front interface. For the example given here the spacer impedance is taken to be qo. The properties of this shield are not dissimilar to those of the magnetic shield as can be seen from the centre panel of Fig. 1. It can be shown that, for high freque ...
... representing the equivalent wave impedance at the front interface. For the example given here the spacer impedance is taken to be qo. The properties of this shield are not dissimilar to those of the magnetic shield as can be seen from the centre panel of Fig. 1. It can be shown that, for high freque ...
Determining Planck`s Constant
... Avoid looking directly at the diodes when they are brightly lit. Do not turn the voltage/current up too high so as to avoid burning out the LEDs. o NOTE: You will never exceed 5 V in this experiment. Do not exceed the maximum current on the DC power supply. This can result in damage to the device an ...
... Avoid looking directly at the diodes when they are brightly lit. Do not turn the voltage/current up too high so as to avoid burning out the LEDs. o NOTE: You will never exceed 5 V in this experiment. Do not exceed the maximum current on the DC power supply. This can result in damage to the device an ...
Effects of Bonding and Packaging on Circuit Operation Speed
... However, these buffers, comprised of inverters whose size increases geometrically, take up valuable chip real estate. We expect the performance loss will be more substantial as chip feature sizes decrease with progressing technology. The factors, which affect operation speed, that decrease as the mi ...
... However, these buffers, comprised of inverters whose size increases geometrically, take up valuable chip real estate. We expect the performance loss will be more substantial as chip feature sizes decrease with progressing technology. The factors, which affect operation speed, that decrease as the mi ...
Current source
A current source is an electronic circuit that delivers or absorbs an electric current which is independent of the voltage across it.A current source is the dual of a voltage source. The term constant-current 'sink' is sometimes used for sources fed from a negative voltage supply. Figure 1 shows the schematic symbol for an ideal current source, driving a resistor load. There are two types - an independent current source (or sink) delivers a constant current. A dependent current source delivers a current which is proportional to some other voltage or current in the circuit.