AIFP® Datasheet :: MicroStrain® Arthroscopically Implantable Force
... and ultra-flexible, flat tape cable keep the device anchored and oriented within fibrous materials. Specialized instruments have been developed to bury the transducer within tissue substance. A suture eyelet in the wall of the probe facilitates removal. The device is fully encapsulated with vacuum d ...
... and ultra-flexible, flat tape cable keep the device anchored and oriented within fibrous materials. Specialized instruments have been developed to bury the transducer within tissue substance. A suture eyelet in the wall of the probe facilitates removal. The device is fully encapsulated with vacuum d ...
FJV3 104R NPN Epitaxial Silicon Transistor
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
... support device or system whose failure to perform can systems which, (a) are intended for surgical implant into be reasonably expected to cause the failure of the life the body, or (b) support or sustain life, or (c) whose support device or system, or to affect its safety or failure to perform when ...
Linear Systems replaces discontinued Intersil IT120
... 1. Absolute Maximum ratings are limiting values above which serviceability may be impaired 2. The reverse base‐to‐emitter voltage must never exceed 6.2 volts; the reverse base‐to‐emitter current must never exceed 10µA. ...
... 1. Absolute Maximum ratings are limiting values above which serviceability may be impaired 2. The reverse base‐to‐emitter voltage must never exceed 6.2 volts; the reverse base‐to‐emitter current must never exceed 10µA. ...
1760 Three-Phase Power Quality Recorder Topas
... power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement selections. It has 8 input channels ( ...
... power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement selections. It has 8 input channels ( ...
Preparation of Papers to be Submitted to CDE-2001 (Times 20
... mechanical structures and also acts as bottom electrode. A thermal oxide film is used for interlayer isolation. ...
... mechanical structures and also acts as bottom electrode. A thermal oxide film is used for interlayer isolation. ...
Modifying a Walker for Use in Rehabilitation of Spinal Cord Injuries
... Introduction! There are approximately 270,000 people in the United States that currently suffer from spinal cord injury (SCI), with approximately 12,000 new cases each year1. This type of injury commonly leads to paraplegia, which greatly reduces the mobility of these patients2. This makes it very i ...
... Introduction! There are approximately 270,000 people in the United States that currently suffer from spinal cord injury (SCI), with approximately 12,000 new cases each year1. This type of injury commonly leads to paraplegia, which greatly reduces the mobility of these patients2. This makes it very i ...
#16 McGill University Formula Hybrid Design Review
... 132 motor could overheat from the EX-21’s waste heat conducting through the coupling cylinder. Proper heat barriers (silicon & Delrin gaskets) and cooling (fan) have been implemented following the test results. In terms of the dynamics between the generator and the battery, the testing showed that, ...
... 132 motor could overheat from the EX-21’s waste heat conducting through the coupling cylinder. Proper heat barriers (silicon & Delrin gaskets) and cooling (fan) have been implemented following the test results. In terms of the dynamics between the generator and the battery, the testing showed that, ...
Reducing System Power Requirements
... Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is cu ...
... Texas Instruments (TI) reserves the right to make changes to its products or to discontinue any semiconductor product or service without notice, and advises its customers to obtain the latest version of relevant information to verify, before placing orders, that the information being relied on is cu ...
RevG_092
... local airframe ground. The Hi-pot test is not applicable for any EUT containing electronic components. The dielectric withstand voltage test level shall be at least the peak amplitude of a level in Table 22-2. When testing pins which normally have a bias voltage, i.e. power line inputs or other sour ...
... local airframe ground. The Hi-pot test is not applicable for any EUT containing electronic components. The dielectric withstand voltage test level shall be at least the peak amplitude of a level in Table 22-2. When testing pins which normally have a bias voltage, i.e. power line inputs or other sour ...
ILSCOPedia \ Electrical Industry Terminology
... The voltage of the secondary can be higher or lower than the voltage that drives the primary and is determined by the ratio of turns of wire in the two coils. Isolation refers to the fact that the coils are connected only by a magnetic field, so they can be independent of a common ground. ...
... The voltage of the secondary can be higher or lower than the voltage that drives the primary and is determined by the ratio of turns of wire in the two coils. Isolation refers to the fact that the coils are connected only by a magnetic field, so they can be independent of a common ground. ...
Thruster Electrical Service Notes
... All QL bow thrusters use similar wiring of the controls. The drive motor is a DC 12 or 24 series wound that is designed to draw a high current and to run in short bursts. There is a large reversing solenoid with two separate coils that are used to run the motor forward or reverse. The control circui ...
... All QL bow thrusters use similar wiring of the controls. The drive motor is a DC 12 or 24 series wound that is designed to draw a high current and to run in short bursts. There is a large reversing solenoid with two separate coils that are used to run the motor forward or reverse. The control circui ...
miniature, i/o proportional high voltage power supplies
... in a compact PCB mount package. The isolated output is directly proportional to the input, and is linear from approximately 0.7 volts in. Excellent filtering techniques and a low noise quasi-sinewave oscillator provide clean, reliable DC to HV DC conversion with low ripple, and low EMI/RFI. The isol ...
... in a compact PCB mount package. The isolated output is directly proportional to the input, and is linear from approximately 0.7 volts in. Excellent filtering techniques and a low noise quasi-sinewave oscillator provide clean, reliable DC to HV DC conversion with low ripple, and low EMI/RFI. The isol ...