Medical Applications Guide (Rev. B
... Digital thermometers are quickly replacing traditional mercury thermometers. Digital thermometers are fast, accurate and effective. With newer technologies, different types of digital fever thermometers may be classified on the basis of the location where they are used such as oral, rectal, underarm ...
... Digital thermometers are quickly replacing traditional mercury thermometers. Digital thermometers are fast, accurate and effective. With newer technologies, different types of digital fever thermometers may be classified on the basis of the location where they are used such as oral, rectal, underarm ...
Standard-compliant switchgear and controlgear production
... promise made between the user and manufacturer of a switchgear or controlgear assembly. In this way, fulfilment of the performance promise can be assessed and documented for both parties. Application of the new standard does not entail significantly more work than testing a TTA/PTTA assembly. The ca ...
... promise made between the user and manufacturer of a switchgear or controlgear assembly. In this way, fulfilment of the performance promise can be assessed and documented for both parties. Application of the new standard does not entail significantly more work than testing a TTA/PTTA assembly. The ca ...
EPM9650spec - GE Grid Solutions
... Memory shall be allocated to the various logging functions required. All logging features required shall be simultaneously available at the specified levels. Exercising any one feature at the specified level shall not limit exercising of any or all other features to their full, specified level. ...
... Memory shall be allocated to the various logging functions required. All logging features required shall be simultaneously available at the specified levels. Exercising any one feature at the specified level shall not limit exercising of any or all other features to their full, specified level. ...
Annex B (informative) History of automatic reclosing - pes-psrc
... The existence of an IEEE Standard does not imply that there are no other ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IEEE standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to c ...
... The existence of an IEEE Standard does not imply that there are no other ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IEEE standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to c ...
S260-60-3
... We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our “Safety For Life” mission. ...
... We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our “Safety For Life” mission. ...
AD5757 Data Sheet Quad Channel, 16-Bit,
... power supply range from 10.8 V to 33 V. On-chip dynamic power control minimizes package power dissipation by regulating the voltage on the output driver from 7.4 V to 29.5 V using ...
... power supply range from 10.8 V to 33 V. On-chip dynamic power control minimizes package power dissipation by regulating the voltage on the output driver from 7.4 V to 29.5 V using ...
MICROWAVE OVEN SERVICE MANUAL
... oven unit found to have a microwave emission level in excess of 5 mW/cm2 and should repair any unit found to have excessive emission levels, at no cost to the owner, and should ascertain the cause of the excessive leakage. The service personnel should instruct the owner not to use the unit until the ...
... oven unit found to have a microwave emission level in excess of 5 mW/cm2 and should repair any unit found to have excessive emission levels, at no cost to the owner, and should ascertain the cause of the excessive leakage. The service personnel should instruct the owner not to use the unit until the ...
MetraBus User`s Manual - Measurement Computing
... current price. I/O boards face some harsh environments, some harsher than the boards are designed to withstand. When that happens, just return the board with an order for its replacement at only 50% of the list price. Measurement Computing Corp. does not need to profit from your misfortune. By the w ...
... current price. I/O boards face some harsh environments, some harsher than the boards are designed to withstand. When that happens, just return the board with an order for its replacement at only 50% of the list price. Measurement Computing Corp. does not need to profit from your misfortune. By the w ...
Section 3 GDT Telecom Applications Protection Examples
... silicon devices such as SIDACtors or TVS diodes. Gas Discharge Tubes / Surge Arresters are mostly used for Primary Protection against transients caused by lightning. Secondary Protection applications traditionally have used Silicon solutions but due to the increased bandwidth now required by telepho ...
... silicon devices such as SIDACtors or TVS diodes. Gas Discharge Tubes / Surge Arresters are mostly used for Primary Protection against transients caused by lightning. Secondary Protection applications traditionally have used Silicon solutions but due to the increased bandwidth now required by telepho ...
The Connecticut Light and Power Company The United Illuminating
... The Generating Facility shall not: (i) actively regulate the voltage of the EPS unless specifically agreed by the EDC; (ii) cause the voltage at any point along the EPS to deviate from the levels prescribed by the State of Connecticut (+3% / -5% of nominal); or (iii) cause any voltage deviations, wh ...
... The Generating Facility shall not: (i) actively regulate the voltage of the EPS unless specifically agreed by the EDC; (ii) cause the voltage at any point along the EPS to deviate from the levels prescribed by the State of Connecticut (+3% / -5% of nominal); or (iii) cause any voltage deviations, wh ...
Emon Meter Installation
... Part # E-Mon Meters AMR Jack 8-pin RJ-45, used to connect kWh meter to E-Mon EnergyTM/IDR Peripheral Jack 6-pin RJ-11 jack used to interface meter withperipherals such as the P2 Pulser or the D/A converter Check Sensor LED When lit, indicates that the current sensor is backwards or on the inc ...
... Part # E-Mon Meters AMR Jack 8-pin RJ-45, used to connect kWh meter to E-Mon EnergyTM/IDR Peripheral Jack 6-pin RJ-11 jack used to interface meter withperipherals such as the P2 Pulser or the D/A converter Check Sensor LED When lit, indicates that the current sensor is backwards or on the inc ...
Power Plant “Horror Stories” - Beckwith Electric Co., Inc.
... substantially exacerbating damage. On the other hand, operating an ungrounded generator provides negligible fault current, but the line-to-ground voltages on the unfaulted phases can rise during arcing type faults to dangerously high levels which could cause the failure of generation insulation. As ...
... substantially exacerbating damage. On the other hand, operating an ungrounded generator provides negligible fault current, but the line-to-ground voltages on the unfaulted phases can rise during arcing type faults to dangerously high levels which could cause the failure of generation insulation. As ...
Damping of Power System Oscillations using Unified Power Flow
... constrained by transient stability, voltage stability and small signal stability. These constraints limit a full utilization of available transmission corridors. Flexible AC Transmission System (FACTS) is the technology that provides the needed corrections of the transmission functionality in order ...
... constrained by transient stability, voltage stability and small signal stability. These constraints limit a full utilization of available transmission corridors. Flexible AC Transmission System (FACTS) is the technology that provides the needed corrections of the transmission functionality in order ...
AN84 - Linear Technology Magazine Circuit Collection, Volume IV
... and to track it up to a maximum of fMAX = 2 • fMIN. A logic signal may also be coupled to PLL LPF to effect a 2:1 frequency shift, provided that the initial frequency has been set to less than 200kHz. ...
... and to track it up to a maximum of fMAX = 2 • fMIN. A logic signal may also be coupled to PLL LPF to effect a 2:1 frequency shift, provided that the initial frequency has been set to less than 200kHz. ...
commercial electric Water HeaterS
... in this manual. 5 Using an AC volt meter measure the branch circuit power supply voltage to the water heater. Ensure the measured voltage of the branch circuit supplying power to the water heater matches the water heater’s rating label - see pages 12 - 14. 6 Ensure the internal power phase configura ...
... in this manual. 5 Using an AC volt meter measure the branch circuit power supply voltage to the water heater. Ensure the measured voltage of the branch circuit supplying power to the water heater matches the water heater’s rating label - see pages 12 - 14. 6 Ensure the internal power phase configura ...
section 26 29 23 - variable frequency motor controllers
... BACnet and Modbus RTU. These protocols shall be accessible via a RS-422/485 communication port. A compatible adapter/card shall be provided for the approved protocol to allow integration of the VFD to the building control system. Verify which protocol is required for the project before VFD order is ...
... BACnet and Modbus RTU. These protocols shall be accessible via a RS-422/485 communication port. A compatible adapter/card shall be provided for the approved protocol to allow integration of the VFD to the building control system. Verify which protocol is required for the project before VFD order is ...