DC/DC converter, part 1
... Unregulated DC input, controlled DC output Regulated DC may be larger or smaller than the unregulated DC voltage Input to DC-DC converter may vary a lot ...
... Unregulated DC input, controlled DC output Regulated DC may be larger or smaller than the unregulated DC voltage Input to DC-DC converter may vary a lot ...
Old Company Name in Catalogs and Other Documents
... 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration ...
... 1. Renesas Technology Corp. puts the maximum effort into making semiconductor products better and more reliable, but there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or property damage. Remember to give due consideration ...
A DC-DC conversion powering scheme for the CMS Phase
... modules, which are very similar to the future ones. AC PIX V8 DC-DC converters provided the required 3.0 V and 2.4 V. Eight DC-DC converters were plugged into a small version of the prototype bus board. The original pixel power supplies and supply cables were used, and the cabling between the DC-DC ...
... modules, which are very similar to the future ones. AC PIX V8 DC-DC converters provided the required 3.0 V and 2.4 V. Eight DC-DC converters were plugged into a small version of the prototype bus board. The original pixel power supplies and supply cables were used, and the cabling between the DC-DC ...
Electrical Safety and Isolation in High Voltage Applications
... The general requirements are that a single level of insulation is acceptable if the circuit is not accessible, but wherever there are accessible components, they must be insulated from hazardous voltages by a doublelevel system, and each level must meet the insulation specifications appropriate to t ...
... The general requirements are that a single level of insulation is acceptable if the circuit is not accessible, but wherever there are accessible components, they must be insulated from hazardous voltages by a doublelevel system, and each level must meet the insulation specifications appropriate to t ...
ISSCC 2017
... fundamentally performed with analog systems. Therefore, the key technologies for power management are predominantly analog. For example, there is much interest in wireless power transmission for battery charging applications, ranging from mobile handsets to medical implants: increased performance in ...
... fundamentally performed with analog systems. Therefore, the key technologies for power management are predominantly analog. For example, there is much interest in wireless power transmission for battery charging applications, ranging from mobile handsets to medical implants: increased performance in ...
MSRT-Pro 1-3K Neutral English Manual
... 1. Outlet Turn On After UPS On– select the time to automatically enable this outlet within the specified time when the UPS is powered on. If “0” sec is selected, the outlet will be enabled once the UPS is powered on. 2. Outlet Turn Off After AC Failure – select this option to automatically disable ...
... 1. Outlet Turn On After UPS On– select the time to automatically enable this outlet within the specified time when the UPS is powered on. If “0” sec is selected, the outlet will be enabled once the UPS is powered on. 2. Outlet Turn Off After AC Failure – select this option to automatically disable ...
pipemaster - Magnatech LLC
... • Detachable coolant recirculator with integral flow switch protection • Meets applicable NEMA, CE, CSA standards ...
... • Detachable coolant recirculator with integral flow switch protection • Meets applicable NEMA, CE, CSA standards ...
Dynamic Testing of Permanent Magnet Synchronous Machines
... insecure fossil-energy dependence. It took part in the bigger venture ELDRIVET, which intended to support the transition from combustion engines to electric drives in the Swedish vehicles eet. Within ELDRIVET, the DTM project was assigned to develop a test method to facilitate the development, manu ...
... insecure fossil-energy dependence. It took part in the bigger venture ELDRIVET, which intended to support the transition from combustion engines to electric drives in the Swedish vehicles eet. Within ELDRIVET, the DTM project was assigned to develop a test method to facilitate the development, manu ...
Deploying Brocade FastIron-based PoE and PoE+ Solutions in the
... distributed enterprises with changing business needs. FastIron WS switches are available in 24- and 48port 10/100 or 10/100/1000 Mbps models, with or without IEEE 802.3af PoE, for enterprise edge networking, security, and unified communication needs. Featuring standards-based PoE, the FastIron WS de ...
... distributed enterprises with changing business needs. FastIron WS switches are available in 24- and 48port 10/100 or 10/100/1000 Mbps models, with or without IEEE 802.3af PoE, for enterprise edge networking, security, and unified communication needs. Featuring standards-based PoE, the FastIron WS de ...
Power Supplies for High-Power Piezoelectric
... reduced without increasing the switching frequency. Control schemes are proposed for driving the MM-USM. For control design, an averaging model of the MM-USM driven by LLCC PWM inverter is studied and verified by simulation results at transient and steady state conditions. A feedforward voltage cont ...
... reduced without increasing the switching frequency. Control schemes are proposed for driving the MM-USM. For control design, an averaging model of the MM-USM driven by LLCC PWM inverter is studied and verified by simulation results at transient and steady state conditions. A feedforward voltage cont ...
PowerFlex 755 - Rockwell Automation
... All digital input and output functions shall be fully programmable. The control terminal blocks shall be rated for 115V AC. Inputs shall be optically isolated from the drive control logic. The control interface card shall provide input terminals for access to fixed drive functions that include start ...
... All digital input and output functions shall be fully programmable. The control terminal blocks shall be rated for 115V AC. Inputs shall be optically isolated from the drive control logic. The control interface card shall provide input terminals for access to fixed drive functions that include start ...
MS2000 Operation Manual
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment g ...
... This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment. This equipment g ...
Magnet Power Supply - Lake Shore Cryotronics, Inc.
... Lake Shore Cryotronics, Inc. (henceforth Lake Shore), the manufacturer, warrants the instrument to be free from defects in material and workmanship for a period of twelve months from the date of shipment. During the warranty period, under authorized return of instruments or component parts to Lake S ...
... Lake Shore Cryotronics, Inc. (henceforth Lake Shore), the manufacturer, warrants the instrument to be free from defects in material and workmanship for a period of twelve months from the date of shipment. During the warranty period, under authorized return of instruments or component parts to Lake S ...
ME372
... An indicator of energy flow direction is displayed in the left top corner. A physical unit of displayed quantity is shown in the right top corner. The indicator of L1 phase voltage presence is displayed in the middle of the top row. In the LCD bottom row there are eleven signal flags that indicate c ...
... An indicator of energy flow direction is displayed in the left top corner. A physical unit of displayed quantity is shown in the right top corner. The indicator of L1 phase voltage presence is displayed in the middle of the top row. In the LCD bottom row there are eleven signal flags that indicate c ...
STUDY OF ELECTRICAL AND CHEMICAL PROPERTIES OF
... Transformer is a device in static condition. The transformer transforms electrical energy from one circuit to another and important in the power system for voltage level conversion. Transformer failure might cause by several conditions such as an overload condition and most failure were caused by an ...
... Transformer is a device in static condition. The transformer transforms electrical energy from one circuit to another and important in the power system for voltage level conversion. Transformer failure might cause by several conditions such as an overload condition and most failure were caused by an ...
Energy Efficient Lighting Guidance Document for New Construction
... avoid problems reported by others. The purpose of this document is to take field experiences and apply scientific study into why they worked as expected and why they sometimes did not. In their ongoing efforts to encourage State buildings in North Carolina to lead by example, the Department of Envir ...
... avoid problems reported by others. The purpose of this document is to take field experiences and apply scientific study into why they worked as expected and why they sometimes did not. In their ongoing efforts to encourage State buildings in North Carolina to lead by example, the Department of Envir ...
AC and DC Power and Ground Wiring
... All power and ground wiring practices must conform to applicable local codes and regulations. It is believed that the recommendations and guidelines given in this installation planning manual meet or exceed the codes and regulations. The recommendations and wiring diagrams in this installation plann ...
... All power and ground wiring practices must conform to applicable local codes and regulations. It is believed that the recommendations and guidelines given in this installation planning manual meet or exceed the codes and regulations. The recommendations and wiring diagrams in this installation plann ...
Purpose - Yaskawa
... Motor Overload Protection: The VFD shall calculate motor overload based on torque requirements and motor parameters. The motor overload detection level shall be adjustable. The motor overload protection time constant shall be adjustable. Actions taken at time of overload shall be selectable from dec ...
... Motor Overload Protection: The VFD shall calculate motor overload based on torque requirements and motor parameters. The motor overload detection level shall be adjustable. The motor overload protection time constant shall be adjustable. Actions taken at time of overload shall be selectable from dec ...
NTB0102 1. General description Dual supply translating transceiver; auto direction sensing;
... The NTB0102 is a 2-bit, dual supply translating transceiver with auto direction sensing, that enables bidirectional voltage level translation. It features two 2-bit input-output ports (An and Bn), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any vol ...
... The NTB0102 is a 2-bit, dual supply translating transceiver with auto direction sensing, that enables bidirectional voltage level translation. It features two 2-bit input-output ports (An and Bn), one output enable input (OE) and two supply pins (VCC(A) and VCC(B)). VCC(A) can be supplied at any vol ...
1. part 1
... A. The transfer switch shall be electrically operated and mechanically held. The electrical operator shall be a momentarily energized, single-solenoid mechanism. Main operators which include over-current disconnect devices, linear motors or gears shall not be acceptable. The switch shall be mechanic ...
... A. The transfer switch shall be electrically operated and mechanically held. The electrical operator shall be a momentarily energized, single-solenoid mechanism. Main operators which include over-current disconnect devices, linear motors or gears shall not be acceptable. The switch shall be mechanic ...
Forney Industries Welding History
... obtainable. The core is of highest quality laminated silicon steel; the windings from the very best magnet wire. Highest quality insulation goes into its weatherproof and fireproof construction. It has built-in double voltage arc booster that eliminates need of high frequency arc starters. There is ...
... obtainable. The core is of highest quality laminated silicon steel; the windings from the very best magnet wire. Highest quality insulation goes into its weatherproof and fireproof construction. It has built-in double voltage arc booster that eliminates need of high frequency arc starters. There is ...