• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ENERGY CONVERSION ONE
ENERGY CONVERSION ONE

... specially primary winding, this connection provide a path for 3rd harmonic current flow, produced and do not let build up of large 3rd voltages . Also provides a return path for any current imbalances in load • Adding a third winding (tertiary) connected in Δ (a) 3rd harmonic components of voltage i ...
BU7295HFV
BU7295HFV

... (Note 3) The voltage difference between inverting input and non-inverting input is the differential input voltage. Then input terminal voltage is set to more than VSS. (Note 4) An excessive input current will flow when input voltages of more than VDD+0.6V or less than VSS-0.6V are applied. The input ...
Aalborg Universitet Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang; Pang, Ying
Aalborg Universitet Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang; Pang, Ying

... reactive current aligned to the orthogonal q-axis, rather than the active current along with the d-axis which the PoC voltage is aligned to. This is because the coupling capacitor is supposed to withstand most of the grid voltage, and the reactive current thus dominates the current injected into the ...
Electronic Engineering Department, Universitat Politècnica de Catalunya, Barcelona, Spain {aldrete, mateo,
Electronic Engineering Department, Universitat Politècnica de Catalunya, Barcelona, Spain {aldrete, mateo,

... sensing devices is increased by 1ºC is plotted. Figure 9.b shows the voltage sensitivity of the F-DTS compared with its monopolar-ended counterpart. It can be seen that the F-DTS has almost the same sensitivity of the DTS (≈ 8 V/ºC). However the F-DTS presents a larger linear region at the same oper ...
BF961 N–Channel Dual Gate MOS-Fieldeffect Tetrode
BF961 N–Channel Dual Gate MOS-Fieldeffect Tetrode

... 1. Meet all present and future national and international statutory requirements. 2. Regularly and continuously improve the performance of our products, processes, distribution and operating systems with respect to their impact on the health and safety of our employees and the public, as well as the ...
MAX16910C9 Evaluation Kit Evaluates: MAX16910C General Description Features
MAX16910C9 Evaluation Kit Evaluates: MAX16910C General Description Features

... surface-mount 0805 resistor PCB pads R1 and R2. To set the output voltage, select resistor R2 to be less than or equal to 100kI and use the following equation to compute R1: ...
Solution - faculty.ucmerced.edu
Solution - faculty.ucmerced.edu

... We begin with step 1. Because current is conserved in the last diagram, we know that 1 A flows through both the 3 and 6 Ω resistors. The drop in voltage across the 3 Ω resistor is thus ∆V = IR = 3.0 V. The change in voltage across the equivalent 6 Ω resistor is ∆V = IR = 6 V. Step 2 - We split up t ...
MAX17498A/MAX17498B/MAX17498C AC-DC and DC-DC Peak Current-Mode Converters for Flyback/Boost Applications
MAX17498A/MAX17498B/MAX17498C AC-DC and DC-DC Peak Current-Mode Converters for Flyback/Boost Applications

... with a minimum number of external components. They contain all the control circuitry required to design wide input voltage isolated and nonisolated power supplies. The MAX17498A has its rising/falling undervoltage lockout (UVLO) thresholds optimized for universal offline (85V AC to 265V AC) applicat ...
Amateur Extra Licensing Class
Amateur Extra Licensing Class

... specifications, but they do come closer than most other types of amplifiers. The gain of an op amp is the function of the input resistor and the feed back resistor. Gain in calculated by dividing the input resistor RI value into the feedback resistor RF. In figure E7-4 if the input resistor,R1, is 1 ...
LM3647 Universal Battery Charger for Li-Ion, Ni-MH and Ni-Cd Batteries LM3647 FEATURES DESCRIPTION
LM3647 Universal Battery Charger for Li-Ion, Ni-MH and Ni-Cd Batteries LM3647 FEATURES DESCRIPTION

... highly recommended for safety reasons) is within limit. Charging starts with a current of 0.2C and switches into next phase after approx. 1 minute. Error termination will be triggered if the battery voltage does not reach the Li-Ion battery qualification level (CEL-pin < 1.2V) within one minute. • F ...
Advanced Electrical Design Models
Advanced Electrical Design Models

TPS2376-H 数据资料 dataSheet 下载
TPS2376-H 数据资料 dataSheet 下载

... Inrush current limiting prevents current drawn by the bulk capacitor from causing the line voltage to sag below the lower UVLO threshold. Adjustable inrush current limiting allows the use of arbitrarily large capacitors and also accommodates legacy systems that require low inrush currents. The ILIM ...
Electric Frequently Asked Questions
Electric Frequently Asked Questions

... Statistics show that fuse panels have a significantly higher risk of causing a fire than breaker panels. This is usually due to the fuse being loosely screwed in, or the contacts corroding and heating up over time, or the wrong size fuse being installed, or the proverbial "replace the fuse with a pe ...
REF3012 数据资料 dataSheet 下载
REF3012 数据资料 dataSheet 下载

... special care must be taken with the combination of low equivalent series resistance (ESR) capacitors and high capacitance. This caution is especially true for low-output voltage devices; therefore, the REF3012 should only have a low-ESR capacitance of 10µF or less. Figure 2 shows the typical connect ...
Animal Contact Current Mitigation
Animal Contact Current Mitigation

... (s) "Steady state" means a 1 minute average of RMS voltage or amperage values. (t) "Stray voltage," also referred to as AcV, means the measured difference in an AC electrical potential when measured with a shunt resistor between 2 points that an animal can simultaneously contact in locations normall ...
DC1521 - LT3956EUHE Evaluation Kit Quick
DC1521 - LT3956EUHE Evaluation Kit Quick

... PWM dimming terminal. For the highest pwm dimming ratio, it is recommended to use 100Hz as a pwm dimming frequency. Information regarding PWM dimming ratios and performance can be found in the LT3956 datasheet in the applications section. Soft-start is provided with a simple and small capacitor to m ...
LMV761, LMV762/Q - Texas Instruments
LMV761, LMV762/Q - Texas Instruments

MAX8516/MAX8517/MAX8518 1.425V to 3.6V Input, 1A, 0.2V Dropout LDO Regulators General Description
MAX8516/MAX8517/MAX8518 1.425V to 3.6V Input, 1A, 0.2V Dropout LDO Regulators General Description

... ambient air, and the rate of airflow. The power dissipated in the device is P = IOUT ✕ (VIN - VOUT). The package features an exposed thermal pad on its underside. This pad lowers the thermal resistance of the package by providing a direct heat conduction path from the die to the PCB. ...
EDR 3 - Elements SRL
EDR 3 - Elements SRL

ad558
ad558

Electric Current
Electric Current

... One is a source of voltage difference that can be provided by a battery or an electrical outlet. • Another is one or more devices that use electrical energy. ( Each one adds Resistance to the circuit) • Circuits also include conductors such as wires that connect the devices to the source of voltage ...
Chapter 13
Chapter 13

... proportional to its area A, and inversely proportional to the distance between its plates d. Hence C  A/d – the constant of proportionality is the permittivity  of the dielectric – the permittivity is normally expressed as the product of the absolute permittivity 0 and the relative permittivity  ...
Ch. 32 - Inductance and Magnetic Energy
Ch. 32 - Inductance and Magnetic Energy

... • But if the current changes, B changes and so then does FB, and Faraday tells us there will be an induced emf. • Lenz’s law tells us that the induced emf must be in such a direction as to produce a current which makes a magnetic field opposing the change. ...
June 4th Summer Quarter Starts
June 4th Summer Quarter Starts

... o Operation of the general circuit breaker must also isolate any pre-charge resistors, if installed. o In order to prevent contact melting of the general circuit breaker its ampere square seconds characteristics, representing heat energy dissipated on the breaker contacts during switching, must be s ...
Synchronous Machine
Synchronous Machine

< 1 ... 596 597 598 599 600 601 602 603 604 ... 1574 >

Surge protector



A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report