as a PDF
... filter. The training of the NN is done using the Neural Network toolbox of MATLAB. A. Simulation Results We simulate the proposed NN controller using PSpice, which has accurate models of switching components and diodes. The weights and biases from MATLAB simulations are put into the PSpice model. Th ...
... filter. The training of the NN is done using the Neural Network toolbox of MATLAB. A. Simulation Results We simulate the proposed NN controller using PSpice, which has accurate models of switching components and diodes. The weights and biases from MATLAB simulations are put into the PSpice model. Th ...
AN1978
... - Vcc Short circuit protection 5.1. VDD under-voltage The ST8004 logic circuitry is supplied by VDD; in order to avoid voltage spikes causing bad behaviors of device and card, a voltage supervisor block is embedded as shown in Figure 1. This check block allows the deactivation of the card when the V ...
... - Vcc Short circuit protection 5.1. VDD under-voltage The ST8004 logic circuitry is supplied by VDD; in order to avoid voltage spikes causing bad behaviors of device and card, a voltage supervisor block is embedded as shown in Figure 1. This check block allows the deactivation of the card when the V ...
BD8306MUV
... CMOS inverter circuit for driving the built-in Pch/Nch FET.Dead time is provided for preventing feedthrough during switching.The dead time is set at about 15 nsec for each individual SWs. ...
... CMOS inverter circuit for driving the built-in Pch/Nch FET.Dead time is provided for preventing feedthrough during switching.The dead time is set at about 15 nsec for each individual SWs. ...
Introductory Circuit Analysis, Tenth Edition
... 26. The capacitor in Fig. 10.88 is initially charged to 3 V with the polarity shown. a. Find the mathematical expressions for the voltage vC and the current iC when the switch is closed. b. Sketch the waveforms for vC and iC. *27. The capacitor of Fig. 10.89 is initially charged to 12 V with the pol ...
... 26. The capacitor in Fig. 10.88 is initially charged to 3 V with the polarity shown. a. Find the mathematical expressions for the voltage vC and the current iC when the switch is closed. b. Sketch the waveforms for vC and iC. *27. The capacitor of Fig. 10.89 is initially charged to 12 V with the pol ...
9-W Stereo Class-D Audio Power Amplifier w/DC Volume Control
... are enabled. Variable outputs (VAROUTL and VAROUTR) are still enabled in Class-D mode to be used as line-level outputs for external amplifiers. ...
... are enabled. Variable outputs (VAROUTL and VAROUTR) are still enabled in Class-D mode to be used as line-level outputs for external amplifiers. ...
Parallel Resistance
... Look at the Schematic Diagram View, if Current enters at 1 and travels to the right through the two resistors it will have to leave at 2 . There are multiple paths (two in this case) through the two resistors, this is what is called a Parallel connection. ...
... Look at the Schematic Diagram View, if Current enters at 1 and travels to the right through the two resistors it will have to leave at 2 . There are multiple paths (two in this case) through the two resistors, this is what is called a Parallel connection. ...
S270-20-5 (Discontinued)
... will open during the first, second, or third open interval of the fault interrupting device to isolate permanent faults and confine outages to smaller sections of line. The sectionalizer does not interrupt fault current but can be closed into a faulted line. lt opens during the open interval of the ...
... will open during the first, second, or third open interval of the fault interrupting device to isolate permanent faults and confine outages to smaller sections of line. The sectionalizer does not interrupt fault current but can be closed into a faulted line. lt opens during the open interval of the ...
mGARD-100 - I-Gard
... All installation, servicing and testing referred to in this manual must be performed by qualified personnel. All power should be disconnected prior to removing covers or enclosures and where live conductors may otherwise be exposed. Failure to observe these precautions may result in death or severe ...
... All installation, servicing and testing referred to in this manual must be performed by qualified personnel. All power should be disconnected prior to removing covers or enclosures and where live conductors may otherwise be exposed. Failure to observe these precautions may result in death or severe ...
Issues to Consider when Substituting Large Power Transformers in
... The system and transformer medium/high/extra high voltage ratings are well standardized and correlated in ANSI C84.1 [7] and IEC 60038 [8]. However, the generators standards do not specify standard series, neither preferable values for the rated stator voltage. The generator stator voltage rating is ...
... The system and transformer medium/high/extra high voltage ratings are well standardized and correlated in ANSI C84.1 [7] and IEC 60038 [8]. However, the generators standards do not specify standard series, neither preferable values for the rated stator voltage. The generator stator voltage rating is ...
AD823 Dual 16 MHz, Rail-to-Rail FET Input Amplifier Data Sheet
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
... ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although this product features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to ...
1K/1.5K/2K/3K Online UPS Uninterruptible Power Supply System
... The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery ...
... The UPS system operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. Caution - risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet), components inside the UPS system are still connected to the battery ...
Title Electric Springs—A New Smart Grid Technology Author(s) Hui
... offers a new solution to supporting the mains voltage in future power systems with intermittent renewable energy source. The series connection with the load makes the electric spring behaves like a “voltage suspension,” analogous to the mechanical suspension spring [7] for a mechanical load (such as ...
... offers a new solution to supporting the mains voltage in future power systems with intermittent renewable energy source. The series connection with the load makes the electric spring behaves like a “voltage suspension,” analogous to the mechanical suspension spring [7] for a mechanical load (such as ...
Grounding & Bonding
... and serves this main purpose. High-voltage system windings are grounded to the earth to help limit high voltage imposed on the system windings from lightning, unintentional contact with higher-voltage lines, or line surges. Grounding Electrical Equipment to the Earth. Metal parts of electrical equip ...
... and serves this main purpose. High-voltage system windings are grounded to the earth to help limit high voltage imposed on the system windings from lightning, unintentional contact with higher-voltage lines, or line surges. Grounding Electrical Equipment to the Earth. Metal parts of electrical equip ...
DM74LS373 • DM74LS374 3-STATE Octal D
... designed specifically for driving highly-capacitive or relatively low-impedance loads. The high-impedance state and increased high-logic level drive provide these registers with the capability of being connected directly to and driving the bus lines in a bus-organized system without need for interfa ...
... designed specifically for driving highly-capacitive or relatively low-impedance loads. The high-impedance state and increased high-logic level drive provide these registers with the capability of being connected directly to and driving the bus lines in a bus-organized system without need for interfa ...
LTC2942-1 - 1A Battery Gas Gauge with Internal Sense Resistor
... The LTC2942-1 includes a 14-bit No Latency ∆Σ analogto-digital converter, with internal clock and voltage reference circuits. ...
... The LTC2942-1 includes a 14-bit No Latency ∆Σ analogto-digital converter, with internal clock and voltage reference circuits. ...
Radio-Frequency Semiconductors Diodes
... Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the ent ...
... Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the ent ...
Surge protector
A surge protector (or surge suppressor) is an appliance/device designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. This article primarily discusses specifications and components relevant to the type of protector that diverts (shorts) a voltage spike to ground; however, there is some coverage of other methods.The terms surge protection device (SPD), or transient voltage surge suppressor (TVSS), are used to describe electrical devices typically installed in power distribution panels, process control systems, communications systems, and other heavy-duty industrial systems, for the purpose of protecting against electrical surges and spikes, including those caused by lightning. Scaled-down versions of these devices are sometimes installed in residential service entrance electrical panels, to protect equipment in a household from similar hazards.Many power strips have basic surge protection built in; these are typically clearly labeled as such. However, power strips that do not provide surge protection are sometimes erroneously referred to as ""surge protectors"".