• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Design and Application of a Power Unit to Use Plug
Design and Application of a Power Unit to Use Plug

MAX9550, MAX9551, MAX9552 大电流、快速建立时间能够为TFT LCD快速恢复VCOM电压
MAX9550, MAX9551, MAX9552 大电流、快速建立时间能够为TFT LCD快速恢复VCOM电压

... To insure buffer stability, place a 1µF low-ESR capacitor as close to the OUT pin as possible. However, this value may be reduced if the TFT-LCD panel load provides some of the capacitance and the resistance in series when this capacitance is low. Connect the feedback at OUT using a Kelvin connectio ...
PQ1 Power Quality Relay Full Data Sheet 1.20
PQ1 Power Quality Relay Full Data Sheet 1.20

... The wire cross section must be adequate for 100mA, and insulation must be adequate for the rated voltage. The PQ1 may be connected line-to-neutral or line-to-line. Do not connect any load, including the PQ1, from line-to-ground. If your PQ1 will be monitoring 277 Vrms, 400 Vrms, 480 Vrms, or higher, ...
Unit 4 Operational Amplifiers
Unit 4 Operational Amplifiers

... The standard Op-Amp symbol is shown in left-hand figure below. It has two input terminals, the inverting (-) input and the non-inverting (+) input. The typical Op-Amp operates with two dc supply voltages, one positive and the other negative, as shown in the right-hand figure below. Usually these dc ...
FX2310301036
FX2310301036

... differential topology has been employed for high gain and high bandwidth applications. In order to obtain an input stage with a rail-to-rail input range, a n- and p-channel pair has to be driven in parallel. Without precautions the small signal transconductance (gm) of such a combination depends on ...
Document
Document

... uLi, i = 1, 2, 3, while its amplitude equals exactly one-third of the amplitudes of uLi, this waveform contains exactly all triplen of the harmonic components of uLi. Because of ua = uLi - unp, there are no triplen harmonics left in the phase voltage. This is also true for the general case of balanc ...
RP-35U Line Powered Digital Panel Meter 3 1/2 Digit 0.56” LED
RP-35U Line Powered Digital Panel Meter 3 1/2 Digit 0.56” LED

... Pin L - System Ground: Pin L is the system ground and is common for all input and output circuits. Pin M - +5V output: Pin M provides a +5VDC output for display test purposes, as well as for use in testing or monitoring the internal regulated power supply output. Maximum current availability for aux ...
Sensorless position control of permanent magnet motors with
Sensorless position control of permanent magnet motors with

Calculating Efficiency
Calculating Efficiency

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
DUAL OPERATIONAL AMPLIFIERS WITH INTERNAL REFERENCE TL103W FEATURES
DUAL OPERATIONAL AMPLIFIERS WITH INTERNAL REFERENCE TL103W FEATURES

... Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant ...
DISCUSSION Pontifical Catholic University Rio Grande do
DISCUSSION Pontifical Catholic University Rio Grande do

... sufficient decoupling between the preheating and the steady state operation, so that each may be designed for optimum performance. • The lamp may be started up without the adverse effects on the lamp lifetime. • The filaments power is eliminated after the preheating time, increasing system efficienc ...
The negative dissipation factor and the interpretation of
The negative dissipation factor and the interpretation of

... Abstract: This paper presents the appropriate measurement circuit and interpretation scheme of the dielectric response of oil-paper insulated power transformers. The traditional three terminal measurement technique (voltage source, current input, guard wire) occasionally leads to the appearance of a ...
File - Vijay Solanki
File - Vijay Solanki

...  The AC (Alternating Current) mains waveform in your home is a sine wave and one which constantly alternates between a maximum value and a minimum value over time. The amount of time it takes between each individual repetition or cycle of a sinusoidal waveform is known as its "periodic time" or si ...
multimess - KBR Energy Management
multimess - KBR Energy Management

Electronic Components for Green Power Generation
Electronic Components for Green Power Generation

... interferences coupled in on lines. The high-frequency portions of the symmetrical data signal are decreased so far that EMC problems can be significantly reduced VV Customized designs VV UL 1446 Class 155 (F) Insulation system High current common-mode chokes (power line) VV Wide current range up to ...
TP2000-AP2300 Modellbasierte Entwicklung innovativer
TP2000-AP2300 Modellbasierte Entwicklung innovativer

... The asynchronous machine belongs to the AC machines. The construction of the asynchronous machine is simple and cheap. As the machine does not have brushes and slip rings, it does not require a lot of maintenance. The stator normally has cylindrical shapes with slots on the inner surface. The stator ...
Grid-connected photovoltaic power systems: Technical
Grid-connected photovoltaic power systems: Technical

MAX16907 36V, 2.2MHz Step-Down Converter with Low Operating Current General Description
MAX16907 36V, 2.2MHz Step-Down Converter with Low Operating Current General Description

... automotive buck converter with an integrated high-side switch. The device operates with input voltages from 3.5V to 36V and tolerates input transients up to 42V. During undervoltage events, such as cold-crank conditions, the internal pass device maintains 98% duty cycle. The switching frequency is r ...
Comparing Buck Converter Topologies
Comparing Buck Converter Topologies

BD2202G-LB
BD2202G-LB

Precision Voltage Regulators
Precision Voltage Regulators

... BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product desig ...
Catalogue BIORiphaso MV
Catalogue BIORiphaso MV

... of the power factor correction banks are fully executed within companies of the Group; that guarantees the achievement of the highest quality standard weather of the metalized film or, consequently, the capacitors manufactured. Furthermore, the know how acquired in almost 50 years of metalized film ...
OPA358 3V Single-Supply FEATURES DESCRIPTION
OPA358 3V Single-Supply FEATURES DESCRIPTION

... output and reduces the quiescent current to less than 5µA. This feature is especially useful for portable video applications such as digital still cameras (DSCs) and camera phones, where the equipment is infrequently connected to a TV or other video device. The Enable logic input voltage is referenc ...
VT1418 - CPU Board Resets Sporadically
VT1418 - CPU Board Resets Sporadically

... this happens when the pushbutton reset signal line is extended several feet away from the CPU board. Some customers have reported electrical noise on the Ethernet (CAT5) cable causing sporadic resetting. This was traced to inductive coupling between the Ethernet signals and the pushbutton reset inpu ...
DICKSON ES120 PRO LOGGER OPERATION
DICKSON ES120 PRO LOGGER OPERATION

... • There is a red indicator located on the front lower right of the unit. This indicator will flash every 10 seconds when the unit is sampling and operating properly. If the indicator is not flashing, please verify the following: - The logger memory may be full; download the data and Clear Memory. - ...
< 1 ... 378 379 380 381 382 383 384 385 386 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report