• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
reloc wiring solutions
reloc wiring solutions

... 4 Specify number of ground conductors (1 or 2) in blank. 5 Consult factory for custom requirements. 6 See DBP below for configurations when sold as one unit. ...
BER Scans at Low Optical Power
BER Scans at Low Optical Power

Antenna Detection Application Note
Antenna Detection Application Note

... Many automotive applications also have the need to detect if the antenna is shorted to ground or the battery of the vehicle for fault tracing. Basically, antenna detection is performed by means of its DC characteristics, splitting the DC and RF paths. Two slightly different hardware solutions are he ...
09221053
09221053

... Fig 1: The stand-alone photovoltaic power system Stand-alone photovoltaic power systems are electrical power systems energized by photovoltaic panels which are independent of the utility grid. These types of systems may use solar panels only or may be used in conjunction with a diesel generator or a ...
RevG_158_Attach
RevG_158_Attach

... Manual Reset is the act of cycling all power to the EUT from on to off back to on to clear an EUT fault condition or an EUT latch up. Entering data into the EUT after a test, such as a power interrupt, is not considered to be a Manual Reset unless otherwise specified in applicable equipment performa ...
(ii) Three-phase transformer
(ii) Three-phase transformer

... The no load current I0 is divided into, pure inductance X0 (taking magnetizing components Iμ) and non induction resistance R0 (taking working component Iw) which are connected into parallel across the primary. The value of E1 can be obtained by subtracting I1Z1 from V1. The value of R0 and X0 can be ...
Dynamic Voltage and Frequency Management Based on Variable
Dynamic Voltage and Frequency Management Based on Variable

... the CPU enters its idle mode, its frequency is gradually decreased until it reaches the minimum allowed frequency or until a new workload arrives. Clearly, this frequency updating method is wasteful. The optimum strategy is to set the CPU clock frequency to a value that will finish the workload just ...
Aalborg Universitet Evaluation of Switch Currents in Nine-Switch Energy Conversion Systems
Aalborg Universitet Evaluation of Switch Currents in Nine-Switch Energy Conversion Systems

Evaluation of Switch Currents in Nine-Switch Energy
Evaluation of Switch Currents in Nine-Switch Energy

... SA3 to decrease for a longer interval. The decrease should ideally cease at zero without allowing the switch current to reverse polarity, which if not prevented, will cause current to increase through the anti-parallel diode of SA3 for the considered example. On average over a fundamental cycle, cur ...
EASA-Shaft-Bearing
EASA-Shaft-Bearing

... Bearing current damage usually initially appears visually in the areas of the bearing that are most heavily loaded. The reason for this is that the lubricant film will be thinnest in the areas subjected to the heaviest load. For example, in a belt drive application the damage to the bearing will be ...
DLP3010 (Rev. B) - Texas Instruments
DLP3010 (Rev. B) - Texas Instruments

Aalborg Universitet
Aalborg Universitet

... The magnetic structure of the proposed three-phase integrated inductor for n number of parallel VSCs is shown in Fig. 2(a) (n = 4 in the illustration). The simplified arrangement of the integrated inductor is also shown in Fig. 2(b). The magnetic core is composed of three identical magnetic structur ...
Minimizing Distortion in Operational Transconductance Amplifiers
Minimizing Distortion in Operational Transconductance Amplifiers

Aluminum Electrolytic Capacitor Application Guide
Aluminum Electrolytic Capacitor Application Guide

... have become available. This intrudes on the traditional, highcapacitance province of aluminum electrolytic capacitors. Ceramic capacitors are available in three classes according to dielectric constant and temperature performance. Class 1 (NPO, COG) is suitable for low capacitance, tight tolerance a ...
MAX13223E ±70V Fault-Protected, 3.0V to 5.5V, 2Tx/2Rx RS-232 Transceiver General Description
MAX13223E ±70V Fault-Protected, 3.0V to 5.5V, 2Tx/2Rx RS-232 Transceiver General Description

... The MAX13223E is a +3.0V to +5.5V-powered EIA/TIA232 and V.28 communications interface with fault protection on the RS-232 line interface. This allows shorts of the transmitter outputs and receiver inputs to voltages in the ±70V range without adversely affecting the MAX13223E. The MAX13223E achieves ...
Stakeholder Comment and Reply Matrix AESO AUTHORITATIVE DOCUMENT PROCESS
Stakeholder Comment and Reply Matrix AESO AUTHORITATIVE DOCUMENT PROCESS

... such that system stability is maintained. Once a primary protection system initiates a breaker open signal, there should be no reason for the breaker to take a longer time than specified. However, for low level fault there is no stability concern and longer times can be tolerated. . Accordingly, the ...
Power analysis
Power analysis

... Although it is right that heating and air conditioning account for a very large part of the energy consumption of buildings, in particular residential buildings (approximately 40% in Europe), other energy-consuming processes in the industrial field and also the commercial field may also be improved: ...
Haptic Drive with Auto Resonance Detection for Linear Resonance
Haptic Drive with Auto Resonance Detection for Linear Resonance

Section 3: Switching Regulators
Section 3: Switching Regulators

... components. Although switching regulators do not necessarily require transformers, they do use inductors, and magnetic theory is not generally well understood. However, manufacturers of switching regulators generally offer applications support in this area by offering complete data sheets with recom ...
LTC5592 - Dual 1.6GHz to 2.7GHz High Dynamic Range
LTC5592 - Dual 1.6GHz to 2.7GHz High Dynamic Range

... Note 1: Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. Exposure to any Absolute Maximum Rating condition for extended periods may affect device reliability and lifetime. Note 2: The LTC5592 is guaranteed functional over the case operating temper ...
Stray capacitances of single-layer solenoid air-core inductors
Stray capacitances of single-layer solenoid air-core inductors

... In EMC filtering applications, the frequencies of interest can range up to tens of megahertz. In order to minimize the effects of parasitic capacitances, inductors are usually made of a single wire wound as a single-layer solenoid, and the use of a conductive ferromagnetic core should be avoided. He ...
S225-10-4C
S225-10-4C

... 5. Lift the RAISE-LOWER switch to operate the tap changer two or three steps, then depress the RAISE-LOWER switch to return the tap changer to neutral position. (These steps verify the mechanism is functional.) When on neutral, the NEUTRAL LAMP will glow and the position indicator will point to zero ...
ZR285 Description Pin Assignment
ZR285 Description Pin Assignment

... Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: ...
Characterization of atomic layer deposition HfO2, Al2O3
Characterization of atomic layer deposition HfO2, Al2O3

... method. The films deposited using this method typically result in relatively good electrical, physical, chemical, and thermal characteristics, have good film conformality, and can be deposited at relatively low temperatures.1,2,10,13,14,25 Recently, atomic layer deposited films have also been invest ...
Lambert, S 13 - Newcastle University eTheses
Lambert, S 13 - Newcastle University eTheses

... batteries. Additionally, some load profiles in these applications demand extremely high dynamic behaviour which is either undeliverable by conventional electrochemical batteries or is undesirably damaging to these technologies. As such, a family of electrochemical storage, known generally as superca ...
< 1 ... 119 120 121 122 123 124 125 126 127 ... 1356 >

Stray voltage



Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report