tender specifications
... A way to reduce the earth short circuit current is to have impedance in the neutral-to-ground connections. This impedance has no repercussion in the normal functioning of the network but they introduce a repercussion in the increase of 3x Zo (impedance on the zero sequence component), which reduces ...
... A way to reduce the earth short circuit current is to have impedance in the neutral-to-ground connections. This impedance has no repercussion in the normal functioning of the network but they introduce a repercussion in the increase of 3x Zo (impedance on the zero sequence component), which reduces ...
Document
... arrowhead on the emitter indicates the direction of ‘conventional’ current flow that is, opposite to the electron flow. ...
... arrowhead on the emitter indicates the direction of ‘conventional’ current flow that is, opposite to the electron flow. ...
AK01415111514
... source inverter for various applications. To make this inverter output voltage sinusoidal, a simple L–C filter is normally introduced at the output of this PWM inverter. For high-power applications, the switching frequency of the two-level inverters is very much restricted due to the limitation of t ...
... source inverter for various applications. To make this inverter output voltage sinusoidal, a simple L–C filter is normally introduced at the output of this PWM inverter. For high-power applications, the switching frequency of the two-level inverters is very much restricted due to the limitation of t ...
BDTIC 1N5400 - 1N5408 General Purpose Rectifiers
... DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when p ...
... DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, or (c) whose failure to perform when p ...
Irradiation tests of voltage limiters
... the voltage at the power supply output will be higher then maximum voltage allowed for ASICs. The absolute maximum for ASICs is 5.5 V while the voltage at power supplies will be higher than 8 V in worst cases. In an event of sudden current drop supply voltage at modules could exceed the maximum allo ...
... the voltage at the power supply output will be higher then maximum voltage allowed for ASICs. The absolute maximum for ASICs is 5.5 V while the voltage at power supplies will be higher than 8 V in worst cases. In an event of sudden current drop supply voltage at modules could exceed the maximum allo ...
Using digital multimeter for reading resistors.
... beyond what you are testing. • IE: you think you have a 330 ohm resistor • What value do you set the meter to? ...
... beyond what you are testing. • IE: you think you have a 330 ohm resistor • What value do you set the meter to? ...
2SD1834
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
... No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products" ...
Datasheet
... across sprawling industrial environments typical of industrial applications. The 115E-2 can serve as an end node or network gateway and is scalable to thousands of nodes. Gather-scatter and block mapping technology offers the efficient use of network resources, allowing point-to-point transfer of pr ...
... across sprawling industrial environments typical of industrial applications. The 115E-2 can serve as an end node or network gateway and is scalable to thousands of nodes. Gather-scatter and block mapping technology offers the efficient use of network resources, allowing point-to-point transfer of pr ...
doc
... FADC buffer positive supplies are currently sourced from a 5.5v intermediate voltage. There is one LDO (LT3080) per 8 dual buffer devices. These will now be connected directly to the external +7v linear power supply. The buffers have been changed to reduce the bandwidth and current consumption. Each ...
... FADC buffer positive supplies are currently sourced from a 5.5v intermediate voltage. There is one LDO (LT3080) per 8 dual buffer devices. These will now be connected directly to the external +7v linear power supply. The buffers have been changed to reduce the bandwidth and current consumption. Each ...
1760 Three-Phase Power Quality Recorder Topas
... IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement ...
... IEC 61000-4-30 Class-A, for advanced power quality analysis and consistent compliance testing. Designed for analysis of utility and industrial power distribution systems, in medium and low-voltage networks, the Fluke 1760 provides the flexibility to customize thresholds, algorithms, and measurement ...
Jun 1999 LTC2400 Differential Bridge Digitizers
... LTC2400 Differential Bridge Digitizers by Kevin R. Hoskins and Derek Redmayne This Design Idea covers two circuits that convert differential signals to single-ended, ground referred signals for input to the LTC2400 delta-sigma ADC. These circuits were designed to have a minimal effect on the LTC2400 ...
... LTC2400 Differential Bridge Digitizers by Kevin R. Hoskins and Derek Redmayne This Design Idea covers two circuits that convert differential signals to single-ended, ground referred signals for input to the LTC2400 delta-sigma ADC. These circuits were designed to have a minimal effect on the LTC2400 ...
LDS8641 - IXYS Power
... from VOUT to (VOUT - 1.5V) range, LDS8641 recognizes this condition as “LED Short” and disables this channel. If LED pin voltage is less than (Vout – 1.5V), LDS8641 restores LED current at this particular channel to programmed value. ...
... from VOUT to (VOUT - 1.5V) range, LDS8641 recognizes this condition as “LED Short” and disables this channel. If LED pin voltage is less than (Vout – 1.5V), LDS8641 restores LED current at this particular channel to programmed value. ...
Liebert® PSA
... for small office computers and electronic equipment. Liebert Multilink software automatically powers down your computer in the event of an extended power outage. It also has full event management and display UPS instrumentation on screen. Designed with simple controls for easy operation, the Liebert ...
... for small office computers and electronic equipment. Liebert Multilink software automatically powers down your computer in the event of an extended power outage. It also has full event management and display UPS instrumentation on screen. Designed with simple controls for easy operation, the Liebert ...
Electrostatic Applications
... Little or no resistance is placed in the path of the electrical power charging the entire electrostatic tool-so an operator cannot touch the tool while the power is on. Uninhibited systems are interlocked so personnel cannot touch the atomization tool. The atomizer will store electrons (like a capac ...
... Little or no resistance is placed in the path of the electrical power charging the entire electrostatic tool-so an operator cannot touch the tool while the power is on. Uninhibited systems are interlocked so personnel cannot touch the atomization tool. The atomizer will store electrons (like a capac ...
Text - kbcheney
... if it excites the lowest energy state. More energy can be lost if it is available, mercury has many energy levels above the lowest energy level. The mean free path for collisions is much shorter than the distance between the cathode and grid. Therefore if the electrons gain enough energy to excite t ...
... if it excites the lowest energy state. More energy can be lost if it is available, mercury has many energy levels above the lowest energy level. The mean free path for collisions is much shorter than the distance between the cathode and grid. Therefore if the electrons gain enough energy to excite t ...
instructions to tenderers
... Low Bat. & Overload – Status: battery low or output overload. MAINS – Output of the mains (230Vac / 127Vac). Module for Load at Network Voltage This module must incorporate a 35W halogen lamp and a 3W LED lamp, working to the voltage mains. Each lamp must incorporate an On/OFF control independent sw ...
... Low Bat. & Overload – Status: battery low or output overload. MAINS – Output of the mains (230Vac / 127Vac). Module for Load at Network Voltage This module must incorporate a 35W halogen lamp and a 3W LED lamp, working to the voltage mains. Each lamp must incorporate an On/OFF control independent sw ...
JPARC Horn 1 Outer Conductor Middle Connection
... • Before a connection between the horn and stripline can be worked out, the connection that holds the two halves of the outer conductor must be worked out • The outer conductor must be water-tight and hold off the stripline voltage across an insulating gap – I don’t show water seals in the following ...
... • Before a connection between the horn and stripline can be worked out, the connection that holds the two halves of the outer conductor must be worked out • The outer conductor must be water-tight and hold off the stripline voltage across an insulating gap – I don’t show water seals in the following ...
PAPER
... Increasing interest in distributed wireless systems, such as sensor networks [1] has created the demand for a low-power operational amplifier [2] which can adapt to various operating conditions. A traditional operational amplifier, because of its fixed bias current, consumes constant power regardles ...
... Increasing interest in distributed wireless systems, such as sensor networks [1] has created the demand for a low-power operational amplifier [2] which can adapt to various operating conditions. A traditional operational amplifier, because of its fixed bias current, consumes constant power regardles ...
Five-Channel Power Supply Supervisors
... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer's technical experts. ...
... “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer's technical experts. ...
Stray voltage
Stray voltage is the occurrence of electrical potential between two objects that ideally should not have any voltage difference between them. Small voltages often exist between two grounded objects in separate locations, due to normal current flow in the power system. Large voltages can appear on the enclosures of electrical equipment due to a fault in the electrical power system, such as a failure of insulation.