• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
FMS6502 8-Input, 6-Output Video Switch Matrix with Output Drivers
FMS6502 8-Input, 6-Output Video Switch Matrix with Output Drivers

... clamp rather than a full DC-restore circuit. For video signals with and without sync; (Y,CV,R,G,B), the lowest voltage at the output pins is clamped to approximately 300mV above ground. If symmetric AC-coupled input signals are used (Chroma,Pb,Pr,Cb,Cr), the bias circuit can be used to center them w ...
MAX4501/MAX4502 Low-Voltage, SPST, CMOS Analog Switches _________________General Description _____________________________Features
MAX4501/MAX4502 Low-Voltage, SPST, CMOS Analog Switches _________________General Description _____________________________Features

... CMOS analog switches, except they have only two supply pins: V+ and GND. V+ and GND drive the internal CMOS switches and set the analog voltage limits of the switch. Reverse ESD-protection diodes are internally connected between each analog signal pin and both V+ and GND. One of these diodes conduct ...
UT350 1/4 DIN - McGoff
UT350 1/4 DIN - McGoff

... input range span (0.1 to 0.5% for heating/ cooling control) Setpoint rate-of-change setting = off, or 0.0 to 100.0%/h or min of measured input range span. ...
The laboratory work is done in groups of 3-4 - MyCourses
The laboratory work is done in groups of 3-4 - MyCourses

Ignition Analysis - Snap-on
Ignition Analysis - Snap-on

... kilovolts and represents the amount of voltage required to start a spark across the spark plug gap. Firing voltage must overcome secondary circuit resistance including secondary cables (if present), rotor gap(if present) and the spark plug. Remember that the spark plug air gap is typically the highe ...
EMI/EMP Filter Connectors
EMI/EMP Filter Connectors

... to consider in the selection of filter connectors. Insertion loss is a measure of the degradation experienced by a signal when a device, such as a connector, is inserted into the transmission path. When a filter element performs its job of stripping signal noise from a transmission line, it may atte ...
Datasheet
Datasheet

... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
P83983
P83983

... NOTE: NFPA 72/ANSI 117.1 conform to ADAAG Equivalent Facilitation Guidelines in using fewer, higher intensity strobes within the same protected area. CAUTION: Check the installation instructions of the manufacturers of other equipment used in the system for any guidelines or restrictions on wiring a ...
ENERGY CONVERSION ONE
ENERGY CONVERSION ONE

... • Last figure shows a 2 pole rotor spinning inside a 3 phase stator, without load • Rotor magnetic field BR develop a voltage EA as discussed in last chapter voltage is positive out of conductors, at top, and negative into the conductors at bottom of figure • When there is no load on generator, arma ...
Zenergy Power Inc.
Zenergy Power Inc.

... • Purpose of Proposed Standard: To Provide Guidelines for Testing of Fault Current Limiters Operating on Condition-Based Impedance Increases for AC Systems 1000 V and Above ...
TLC1541 数据资料 dataSheet 下载
TLC1541 数据资料 dataSheet 下载

... TLC1541 can complete conversions in a maximum of 21 µs, while complete input-conversion output cycles can be repeated at a maximum of 31 µs. The system and I/O clocks are normally used independently and do not require any special speed or phase relationships between them. This independence simplifie ...
LM723/LM723C Voltage Regulator (Rev. C)
LM723/LM723C Voltage Regulator (Rev. C)

... Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been de ...
Pad-Mounted Capacitor Banks
Pad-Mounted Capacitor Banks

Complete PDF Edition - Mitsubishi Electric
Complete PDF Edition - Mitsubishi Electric

FINGER PRINT BASED SECURITY SYSTEM
FINGER PRINT BASED SECURITY SYSTEM

SFH655A - Vishay
SFH655A - Vishay

... time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed t ...
Si4063/60-C - Silicon Labs
Si4063/60-C - Silicon Labs

... Note: Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at or beyond these ratings in the operational sections of the specifications is not implied. Exposure to absolute maximum ...
DACs
DACs

... The DNL is the maximum of these deviations over the entire transfer function One must choose a DAC with DNL less than 1 LSB. A DNL > 1 LSB will lead to non-monotonic behavior. This means that for certain steps in digital input, the output voltage will change in the opposite direction. This may cause ...
LT5522 - 600MHz to 2.7GHz High Signal Level Downconverting Mixer.
LT5522 - 600MHz to 2.7GHz High Signal Level Downconverting Mixer.

... LO+ to LO– Differential DC Voltage ......................... ±1V LO Input DC Common Mode Voltage ...................... ±1V RF Input Power ................................................ +10dBm RF+ to RF– Differential DC Voltage ........................ ±0.2V RF Input DC Common Mode Voltage ....... ...
discontinued product
discontinued product

... The UPS is designed to operate as an off-line (standby) system in the following modes: A. Normal - The critical AC load is continuously supplied with filtered power. The battery charger maintains a float-charge on the battery. B. Battery - When the input power source exceeds the parameters defined i ...
GTL2009 3-bit GTL Front-Side Bus frequency comparator
GTL2009 3-bit GTL Front-Side Bus frequency comparator

... Stresses beyond those listed may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under Section 10 “Recommended operating conditions” is not implied. Exposure to absolute-maximum-rated c ...
xr series iii - Magna
xr series iii - Magna

... these power supplies outside of a rack mount equipment enclosure will expose the user to high voltage and/or high current sources. Extreme caution must be used under these circumstances. Two or more XR Series power supplies may be connected in series. Regardless of the number of units or the voltage ...
ADA4940-1/ADA4940-2 (Rev. D)
ADA4940-1/ADA4940-2 (Rev. D)

... Medical imaging Industrial process controls Portable electronics ...
Capacitor Self
Capacitor Self

MPA-460 ANF3/8031 BRUSHLESS SERVO AMPLIFIER
MPA-460 ANF3/8031 BRUSHLESS SERVO AMPLIFIER

... when OFF. When a fault occurs, this output turns ON. This output can also have its polarity inverted by switching the fourth switch on DIP switch S2. Once this is done, this output will be ON if no fault exists. This output would now be thought of as a READY output instead of a FAULT output. The nor ...
< 1 ... 216 217 218 219 220 221 222 223 224 ... 1376 >

Rectifier



A rectifier is an electrical device that converts alternating current (AC), which periodically reverses direction, to direct current (DC), which flows in only one direction. The process is known as rectification. Physically, rectifiers take a number of forms, including vacuum tube diodes, mercury-arc valves, copper and selenium oxide rectifiers, semiconductor diodes, silicon-controlled rectifiers and other silicon-based semiconductor switches. Historically, even synchronous electromechanical switches and motors have been used. Early radio receivers, called crystal radios, used a ""cat's whisker"" of fine wire pressing on a crystal of galena (lead sulfide) to serve as a point-contact rectifier or ""crystal detector"".Rectifiers have many uses, but are often found serving as components of DC power supplies and high-voltage direct current power transmission systems. Rectification may serve in roles other than to generate direct current for use as a source of power. As noted, detectors of radio signals serve as rectifiers. In gas heating systems flame rectification is used to detect presence of a flame.Because of the alternating nature of the input AC sine wave, the process of rectification alone produces a DC current that, though unidirectional, consists of pulses of current. Many applications of rectifiers, such as power supplies for radio, television and computer equipment, require a steady constant DC current (as would be produced by a battery). In these applications the output of the rectifier is smoothed by an electronic filter (usually a capacitor) to produce a steady current.More complex circuitry that performs the opposite function, converting DC to AC, is called an inverter.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report