MAX14595 Low-Power Dual-Channel Logic-Level Translator General Description EVALUATION KIT AVAILABLE
... Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametr ...
... Maxim Integrated cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim Integrated product. No circuit patent licenses are implied. Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time. The parametr ...
Reconfigurable CMOS Mixers for Radio-Frequency Applications Min Wang
... the digital baseband circuits along with the RF/analog circuits on a single chip can greatly alleviate the packaging problem and improve system integration level. However, despite the lower cost, the design and integration of RF/analog circuits in a commercial CMOS technology are not without problem ...
... the digital baseband circuits along with the RF/analog circuits on a single chip can greatly alleviate the packaging problem and improve system integration level. However, despite the lower cost, the design and integration of RF/analog circuits in a commercial CMOS technology are not without problem ...
ISA–60079-11
... D2 – These are national differences from IEC requirements based on existing safety practices. These requirements reflect national safety practices, where empirical substantiation (for the IEC or national requirement) is not available or the text has not been included in the IEC standard. DC – These ...
... D2 – These are national differences from IEC requirements based on existing safety practices. These requirements reflect national safety practices, where empirical substantiation (for the IEC or national requirement) is not available or the text has not been included in the IEC standard. DC – These ...
BDTIC
... IESD_ext = 16A - IESD_int =16A - 5A = 11A IESD_ext : 11A @ Uclamp_ext : 13V (referring to Fig. 5) ...
... IESD_ext = 16A - IESD_int =16A - 5A = 11A IESD_ext : 11A @ Uclamp_ext : 13V (referring to Fig. 5) ...
The effect of a strip-type third electrode of a wire
... significantly as compared with those without the STE, for the positive and negative corona discharges. The peak ozone outputs, about 1,220ppm and 1,304ppm, for the positive and negative corona discharges, respectively, were obtained near 10.0mm in height and 3.0mm in width, these are about 1.88 and ...
... significantly as compared with those without the STE, for the positive and negative corona discharges. The peak ozone outputs, about 1,220ppm and 1,304ppm, for the positive and negative corona discharges, respectively, were obtained near 10.0mm in height and 3.0mm in width, these are about 1.88 and ...
Technical guide Protection criteria for medium voltage
... not possible since the times needed to eliminate the fault on the delivery point do not allow it. To run ring networks, the difficulties in correctly identifying the ground faults according to the status of the network neutral and the settings of the protections defined on the supply side must be co ...
... not possible since the times needed to eliminate the fault on the delivery point do not allow it. To run ring networks, the difficulties in correctly identifying the ground faults according to the status of the network neutral and the settings of the protections defined on the supply side must be co ...
Alstom LGPG111 Service Manual
... A number of protection functions are required to fully protect generators against the adverse effects of the different types of faults and abnormal operating conditions that might occur. The exact forms of protection that are required are dependent on the type, design, size and purpose of the genera ...
... A number of protection functions are required to fully protect generators against the adverse effects of the different types of faults and abnormal operating conditions that might occur. The exact forms of protection that are required are dependent on the type, design, size and purpose of the genera ...
XPS-Q8 - Newport Corporation
... PID with a Velocity Output ..................................................................................................... 8 ...
... PID with a Velocity Output ..................................................................................................... 8 ...
power supplies
... Model AT150F and AT175F transformers provide power to nominal 24 VAC circuits in heating/cooling systems. Although the transformers are typically used in heating/cooling systems, they can be used in any application that does not exceed the load ratings. The transformers include a manual reset button ...
... Model AT150F and AT175F transformers provide power to nominal 24 VAC circuits in heating/cooling systems. Although the transformers are typically used in heating/cooling systems, they can be used in any application that does not exceed the load ratings. The transformers include a manual reset button ...
70 Enhanced Control and 700 Vector Control
... or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written ...
... or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written ...
3 - Schneider Electric België
... Sepam protection functions can be used with low voltage (LV) as long as the conditions below are met: b The distribution circuit must be rated higher than 32 A. b The installation must comply with standard IEC 60364. For additional information about the compatibility of Sepam protection functions wi ...
... Sepam protection functions can be used with low voltage (LV) as long as the conditions below are met: b The distribution circuit must be rated higher than 32 A. b The installation must comply with standard IEC 60364. For additional information about the compatibility of Sepam protection functions wi ...
Resistive opto-isolator
Resistive opto-isolator (RO), also called photoresistive opto-isolator, vactrol (after a genericized trademark introduced by Vactec, Inc. in the 1960s), analog opto-isolator or lamp-coupled photocell, is an optoelectronic device consisting of a source and detector of light, which are optically coupled and electrically isolated from each other. The light source is usually a light-emitting diode (LED), a miniature incandescent lamp, or sometimes a neon lamp, whereas the detector is a semiconductor-based photoresistor made of cadmium selenide (CdSe) or cadmium sulfide (CdS). The source and detector are coupled through a transparent glue or through the air.Electrically, RO is a resistance controlled by the current flowing through the light source. In the dark state, the resistance typically exceeds a few MOhm; when illuminated, it decreases as the inverse of the light intensity. In contrast to the photodiode and phototransistor, the photoresistor can operate in both the AC and DC circuits and have a voltage of several hundred volts across it. The harmonic distortions of the output current by the RO are typically within 0.1% at voltages below 0.5 V.RO is the first and the slowest opto-isolator: its switching time exceeds 1 ms, and for the lamp-based models can reach hundreds of milliseconds. Parasitic capacitance limits the frequency range of the photoresistor by ultrasonic frequencies. Cadmium-based photoresistors exhibit a ""memory effect"": their resistance depends on the illumination history; it also drifts during the illumination and stabilizes within hours, or even weeks for high-sensitivity models. Heating induces irreversible degradation of ROs, whereas cooling to below −25 °C dramatically increases the response time. Therefore, ROs were mostly replaced in the 1970s by the faster and more stable photodiodes and photoresistors. ROs are still used in some sound equipment, guitar amplifiers and analog synthesizers owing to their good electrical isolation, low signal distortion and ease of circuit design.