FSR Integration Guide - SparkFun Electronics
... dynamic response is maintained. However, the converse of this effect is also true, smaller actuators will saturate FSRs earlier in the dynamic range, since the saturation point is reached at a lower force. ...
... dynamic response is maintained. However, the converse of this effect is also true, smaller actuators will saturate FSRs earlier in the dynamic range, since the saturation point is reached at a lower force. ...
Installation Recommendations
... to avoid current loops, the metallic screen should be earthed at one point only. Conductors belonging to the same circuit should be contained within the same pipe, conduit or trunking, or the clamps which fix them should include all the phases, unless they are made of non-magnetic material. In the i ...
... to avoid current loops, the metallic screen should be earthed at one point only. Conductors belonging to the same circuit should be contained within the same pipe, conduit or trunking, or the clamps which fix them should include all the phases, unless they are made of non-magnetic material. In the i ...
MAX9669 10-Bit Programmable Gamma Reference System with MTP for TFT LCDs General Description
... (SDA) and a serial-clock line (SCL). SDA and SCL facilitate communication between the MAX9669 and the master at clock rates up to 400kHz. Figure 1 shows the 2-wire interface timing diagram. The master generates SCL and initiates data transfer on the bus. A master device writes data to the MAX9669 by ...
... (SDA) and a serial-clock line (SCL). SDA and SCL facilitate communication between the MAX9669 and the master at clock rates up to 400kHz. Figure 1 shows the 2-wire interface timing diagram. The master generates SCL and initiates data transfer on the bus. A master device writes data to the MAX9669 by ...
MC33290
... implementers to use Freescale Semiconductor products. There are no express or implied copyright licenses granted hereunder to design or fabricate any integrated circuits or integrated circuits based on the information in this document. Freescale Semiconductor reserves the right to make changes witho ...
... implementers to use Freescale Semiconductor products. There are no express or implied copyright licenses granted hereunder to design or fabricate any integrated circuits or integrated circuits based on the information in this document. Freescale Semiconductor reserves the right to make changes witho ...
Operating Instructions
... In these modes various combinations among the versions BASIC and MASTER Inverter are possible. In general each of the pumps needs to be equipped with a HYDROVAR unit. All the units are connected via the RS485 interface and communicate via the standard MODBUSprotocol (9600 Baud, RTU, N81). To realise ...
... In these modes various combinations among the versions BASIC and MASTER Inverter are possible. In general each of the pumps needs to be equipped with a HYDROVAR unit. All the units are connected via the RS485 interface and communicate via the standard MODBUSprotocol (9600 Baud, RTU, N81). To realise ...
Guide to Low Voltage Busbar Trunking Systems Verified to
... A simple way to deal with this issue of additional heat in the conductors is to use a larger neutral conductor. This applies to the whole of the busbar system including affected tap-off units and associated protective devices with a neutral pole. Busbar trunking manufacturers may provide “oversized” ...
... A simple way to deal with this issue of additional heat in the conductors is to use a larger neutral conductor. This applies to the whole of the busbar system including affected tap-off units and associated protective devices with a neutral pole. Busbar trunking manufacturers may provide “oversized” ...
Alberta Reliability Standard Generator Operation for Maintaining Network Voltages VAR-002-AB-
... operator of a generating unit or the operator of an aggregated generating facility must provide an explanation for why the instruction cannot be met. R2.3 Each operator of a generating unit and operator of an aggregated generating facility that does not monitor the voltage or reactive power at the l ...
... operator of a generating unit or the operator of an aggregated generating facility must provide an explanation for why the instruction cannot be met. R2.3 Each operator of a generating unit and operator of an aggregated generating facility that does not monitor the voltage or reactive power at the l ...
here - IET Labs
... electret-<:ondenser microphones (Figure 1-1). The many available accessories are also described and details of their uses are given. Among the accessories are the GR Type 1560-P42 Preamplifier and the 156(}P62 Power Supply. which is required with the Preamplifier when it i s used with sound-measurin ...
... electret-<:ondenser microphones (Figure 1-1). The many available accessories are also described and details of their uses are given. Among the accessories are the GR Type 1560-P42 Preamplifier and the 156(}P62 Power Supply. which is required with the Preamplifier when it i s used with sound-measurin ...
Readout Methods for Arrays of SiPM
... The flood maps from four sets of resistor values (high, medium1, medium2 and low) are shown in Figure 11. It can be seen that the ‘high’ resistor values reproduce the pixel spacing most accurately. The other images all show some contraction in the X direction. The work demonstrated that the use of h ...
... The flood maps from four sets of resistor values (high, medium1, medium2 and low) are shown in Figure 11. It can be seen that the ‘high’ resistor values reproduce the pixel spacing most accurately. The other images all show some contraction in the X direction. The work demonstrated that the use of h ...
STWD100
... After exceeding the tWD, the WDO is asserted for tPW on STWD100xW, STWD100xX and STWD100xY regardless of possible WDI transitions (see Figure 9). On STWD100xP WDO is asserted for a minimum of 10 µs and a maximum of tWD after exceeding the tWD period (see Figure 8 and Figure 9). The STWD100 has an ac ...
... After exceeding the tWD, the WDO is asserted for tPW on STWD100xW, STWD100xX and STWD100xY regardless of possible WDI transitions (see Figure 9). On STWD100xP WDO is asserted for a minimum of 10 µs and a maximum of tWD after exceeding the tWD period (see Figure 8 and Figure 9). The STWD100 has an ac ...
SN74LVCHR32245A 32-BIT BUS TRANSCEIVER WITH 3-STATE OUTPUTS FEATURES
... direction-control (DIR) input. The output-enable (OE) input can be used to disable the device so that the buses are effectively isolated. The data I/Os and control inputs are overvoltage tolerant. This feature allows the use of this device for down translation in a mixed-voltage environment. The out ...
... direction-control (DIR) input. The output-enable (OE) input can be used to disable the device so that the buses are effectively isolated. The data I/Os and control inputs are overvoltage tolerant. This feature allows the use of this device for down translation in a mixed-voltage environment. The out ...
Stationary Power Distribution Unit (SPDU) 3-phase, 75
... sensing, processing, and locally displaying information relating to output voltages for all three phases of line-to-line and line-to-neutral circuitry; all three phases of output current, output frequency, and output power; as well as minimum and maximum acceptable values. • Premium (p/n PDPMN100) l ...
... sensing, processing, and locally displaying information relating to output voltages for all three phases of line-to-line and line-to-neutral circuitry; all three phases of output current, output frequency, and output power; as well as minimum and maximum acceptable values. • Premium (p/n PDPMN100) l ...
Instruction Manual Model 728 Capacitance Meter BOONTON
... via the rear-panel bias terminals or via the proper pins on the rear edge connector. The applied voltages should not exceed ±200 volts from the HI terminal to ground, or ±400 volts from the LO terminal to ground. When bias is applied to one side only, it is recommended that the other bias terminal b ...
... via the rear-panel bias terminals or via the proper pins on the rear edge connector. The applied voltages should not exceed ±200 volts from the HI terminal to ground, or ±400 volts from the LO terminal to ground. When bias is applied to one side only, it is recommended that the other bias terminal b ...
1734-SG001F-EN-P POINT I/O Modules Selection Guide
... Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Bec ...
... Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://literature.rockwellautomation.com) describes some important differences between solid state equipment and hard-wired electromechanical devices. Bec ...
FZT955 Features Mechanical Data
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
... Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any c ...
AEMC Ground Resistance - Test Equipment Rental
... Measuring Resistance of Grounding Electrodes (62% Method) The 62% method has been adopted after graphical consideration and after actual test. It is the most accurate method but is limited by the fact that the ground tested is a single unit. This method applies only when all three electrodes are in ...
... Measuring Resistance of Grounding Electrodes (62% Method) The 62% method has been adopted after graphical consideration and after actual test. It is the most accurate method but is limited by the fact that the ground tested is a single unit. This method applies only when all three electrodes are in ...
Schedule IV FORM II (Installations of voltage level more than 250V
... metallic parts (not intended as conductors) of all transformers and any other apparatus used for regulating or controlling electricity and all apparatus consuming electricity at voltage exceeding 250V but not exceeding 650V been earthed by two separate and distinct connections with earth? (iii) Have ...
... metallic parts (not intended as conductors) of all transformers and any other apparatus used for regulating or controlling electricity and all apparatus consuming electricity at voltage exceeding 250V but not exceeding 650V been earthed by two separate and distinct connections with earth? (iii) Have ...
Resistive opto-isolator
Resistive opto-isolator (RO), also called photoresistive opto-isolator, vactrol (after a genericized trademark introduced by Vactec, Inc. in the 1960s), analog opto-isolator or lamp-coupled photocell, is an optoelectronic device consisting of a source and detector of light, which are optically coupled and electrically isolated from each other. The light source is usually a light-emitting diode (LED), a miniature incandescent lamp, or sometimes a neon lamp, whereas the detector is a semiconductor-based photoresistor made of cadmium selenide (CdSe) or cadmium sulfide (CdS). The source and detector are coupled through a transparent glue or through the air.Electrically, RO is a resistance controlled by the current flowing through the light source. In the dark state, the resistance typically exceeds a few MOhm; when illuminated, it decreases as the inverse of the light intensity. In contrast to the photodiode and phototransistor, the photoresistor can operate in both the AC and DC circuits and have a voltage of several hundred volts across it. The harmonic distortions of the output current by the RO are typically within 0.1% at voltages below 0.5 V.RO is the first and the slowest opto-isolator: its switching time exceeds 1 ms, and for the lamp-based models can reach hundreds of milliseconds. Parasitic capacitance limits the frequency range of the photoresistor by ultrasonic frequencies. Cadmium-based photoresistors exhibit a ""memory effect"": their resistance depends on the illumination history; it also drifts during the illumination and stabilizes within hours, or even weeks for high-sensitivity models. Heating induces irreversible degradation of ROs, whereas cooling to below −25 °C dramatically increases the response time. Therefore, ROs were mostly replaced in the 1970s by the faster and more stable photodiodes and photoresistors. ROs are still used in some sound equipment, guitar amplifiers and analog synthesizers owing to their good electrical isolation, low signal distortion and ease of circuit design.